Product wizard 
 Website 
English
Deutsch
Français
Italiano
Japanese
Español
Svenska
Россия
繁體中文
简体中文
Polska
한국어
Čeština
Magyar
  
0
0
Quick access
WAZ1 CMA LP 1/5/10A AC
         

Icon
Icon
Icon
 

General ordering data

Version Current monitoring, Input current: 0...1 A AC/ 0...5 A AC/ 0...10 A AC, Output : 4-20 mA, (loop powered)
Order No. 8528660000
Type WAZ1 CMA LP 1/5/10A AC
GTIN (EAN) 4032248160433
Qty. 1 pc(s).
Delivery status This article will no longer be available in the future.
Available until 2023-12-30
Alternative product 2489910000

Dimensions and weights

Depth 112.4 mm
Depth (inches) 4.425 inch
Width 22.5 mm
Width (inches) 0.886 inch
Length 72 mm
Length (inches) 2.835 inch
Net weight 72.9 g

Temperatures

Storage temperature -20 °C...70 °C
Operating temperature 0 °C...70 °C
Humidity at operating temperature 0...95 % (no condensation)

Probability of failure

SIL in compliance with IEC 61508 None
MTTF 564 a

Environmental Product Compliance

REACH SVHC Lead 7439-92-1, 6,6'-di-tert-butyl-2,2'-methylenedi-p-cresol 119-47-1
SCIP f8333314-0c66-4444-aa47-78252861a7fb

Input

Input current 0...1 A AC/ 0...5 A AC/ 0...10 A AC
Input frequency 50...60Hz
Number of inputs 1

Output

Load impedance current ≤ 600 Ω
Number of outputs 1
Offset current max. 100 µA
Output current 4...20 mA (current loop)
Output signal limit Approx. 24 mA

Output (digital)

Max. switching voltage, AC 0 V
Rated switching current 0.1 A
Status indicator LED ON: OK; LED flashing: signal out of range;
LED OFF: Error

Output (analogue)

Output current 4...20 mA (current loop)

General data

Accuracy 0.5 % FSR
Configuration DIP switch
Galvanic isolation 2-way isolator
Rail TS 35
Step response time typ. 700 ms
Temperature coefficient ≤ 200 ppm/K
Voltage supply 13...30 V DC, via output current loop

Insulation coordination

EMC standards EN 55011, EN 61000-6
Galvanic isolation 2-way isolator
Impulse withstand voltage 6 kV
Insulation voltage 4 kVeff / 5 s
Pollution severity 2
Rated voltage 300 V
Surge voltage category III

Connection data

Type of connection Tension-clamp connection
Clamping range, rated connection 1.5 mm²
Clamping range, min. 0.5 mm²
Clamping range, max. 2.5 mm²

Important note

Product information This product will soon be replaced by a new product.
Please do not use with new systems. Please contact our technical support.

Downloads

Approval/Certificate/Document of Conformity
Engineering Data
CADENAS eCATALOG CAX data
Product Change Notification
User Documentation
Catalogues Catalogues in PDF-format
Brochures

Classifications

ETIM 6.0 EC002653
ETIM 7.0 EC002653
ETIM 8.0 EC002653
ETIM 9.0 EC002653
ECLASS 9.0 27-21-01-20
ECLASS 9.1 27-21-01-20
ECLASS 10.0 27-21-01-20
ECLASS 11.0 27-21-01-20
ECLASS 12.0 27-21-01-20
ECLASS 13.0 27-21-01-20

Tender specification sheets

Long specification

Monitoring component for AC currents up to 10A with 4...20 mA loop feed
and electrical isolation
Current monitoring component i
n 22.5 mm width for recording 50/ 60 Hz AC currents
0...1 A / 0...5 A / 0...10 A. Input range can be selected using DIP switches.
Power is fed to the component via the 4...20 mA current loop on the output side.
The input and output circuits have 6 kV of electrical isolation.


Add-on housing for TS35 rail mounting
Dimensions: L/W/H 72/ 22.5/ 92.4 mm
Tension-clamp connection / Nominal cross-section 1.5 mm2
Protection degree: IP 20  


Input                         0...1 A / 0...5 A / 0...10 A AC switchable
                                      50 / 60 Hz
Voltage of measuring circuit 250 V AC

Output                                             4...20 mA current loop
Load resistance            < 600 Ohm Strom
>1 kOhm / voltage
Transmission error           < 0,5% v. E. 
Temperature coefficient 200 ppm / K
Step response time typ. 700 ms
Auxiliary power                                     via output-side current loop
Ambient
temperature range 0 °C...+50 °C

Secure isolation                   EN 50178, 2-way isolation up to 6 kV
Test voltage                               4 kV input against output
Rated
voltage                                         
 300 V AC/DC at overvoltage category III and pollution degree 2
Approvals cULus






Type                                                             WAZ1 CMA LP 1/5/10A ac

Short specification

Monitoring component for AC currents up to 10A with 4...20 mA loop feed and electrical isolation
Current monitoring component in 22.5 mm width for recording 50/ 60 Hz AC currents
0...1 A / 0...5 A / 0...10 A. Input range can be selected using DIP switches.
Power is fed to the component via the 4...20 mA current loop on the output side.
The input and output circuits have 6 kV of electrical isolation.

Approvals

Approvals CE CULUS
ROHS Conform
UL File Number Search UL Website
Certificate no. (cULus) E141197

Related products

Type of connection: Screw connection
Order No.: 8523400000
Type: WAS1 CMA 1/5/10A AC
Version:
Current monitoring, Input current: 0...1 A AC/ 0...5 A AC/ 0...10 A AC, Output : 0-20 mA, 0-10 V
Delivery status:
This article will no longer be available in the future.
 
Type of connection: Screw connection
Order No.: 8528650000
Type: WAS1 CMA LP 1/5/10A AC
Version:
Current monitoring, Input current: 0...1 A AC/ 0...5 A AC/ 0...10 A AC, Output : 4-20 mA, (loop powered)
Delivery status:
This article will no longer be available in the future.
 
Type of connection: Screw connection
Order No.: 8975590000
Type: WAS1 CMA LP 1/5/10A EX
Version:
Current monitoring, Input current: 0...1 A AC/ 0...5 A AC/ 0...10 A AC, Output : 4-20 mA, (loop powered)
Delivery status:
This article will no longer be available in the future.
 
Contact
Weidmüller Interface GmbH & Co. KG
 
+49 5231 14-0
+49 5231 14-292083
More information
Decentralised automation solutions
Energy Management Solutions
Industrial Analytics
Industrial IoT Solutions
More information
Mobility Concepts
Photovoltaics
Wind Solutions
Workplace Solutions
More information
Single Pair Ethernet
Weidmüller Configurator
Support & Service
Contact
Disposal Instructions
Engineering data
Repairs and replacement parts