Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Analogue Signal Conditioning
Power Supplies
Electronics Housings
Lightning and Surge Protection
e-mobility
Photovoltaics
Fieldbus Distributors
Universal range
Application range
Special loads
Sensor isolation
Signal adaption
High switching frequencies
Timing functions
Functional safety
Power
Relay modules with positively driven contacts
SIL3 Safety Relays
SAFESERIES - SIL3 emergency off relay / Fire & Gas
SAFESERIES - SIL3 relay De-energized / energized to Safe
SAFESERIES - SIL3 relay De-energized to Safe
SAFESERIES - SIL3 relay Energized to Safe with line and load monitoring
General ordering data
Version
SAFESERIES, Safety relay,24 V DC -15 / +20%, 35 mA , Max. switching current, internal fuse : 5 A (refer to derating curve), SIL 3, DIN EN 61508
Order No.
1319270000
Type
SCS 24VDC P2SIL3DSES
GTIN (EAN)
4050118125115
Qty.
1 pc(s).
Dimensions and weights
Depth
114.1 mm
Depth (inches)
4.492 inch
Height
117.3 mm
Height (inches)
4.618 inch
Width
22.5 mm
Width (inches)
0.886 inch
Net weight
200 g
Temperatures
Storage temperature
-40 °C...85 °C
Operating temperature
-25 °C...50 °C
Humidity
40 °C / 93 % rel. humidity, no condensation
Environmental Product Compliance
REACH SVHC
Lead 7439-92-1
SCIP
807f1906-ce90-4f93-8801-4b128b343e6b
Input (safety circuit)
Connection designation (safety circuit)
A1, A2
Rated control voltage
24 V DC -15 / +20%
Current consumption
45 mA
Guaranteed current consumption of 24 VDC -10%
35 mA
Inrush current
≤ 80 mA / 40 ms
Pull-in/drop-out voltage DC coil
17 V / 12.5 V (DTS)
Status indicator
LED yellow
Protective circuit
Rectifier
Test inputs (safety circuit)
Connection designation (safety test)
X1, X2, X3
Rated control voltage
24 V DC
Number of test inputs
2
Status indicator
LED red flashing: test input is triggered
Output (safety circuit)
Connection designation (safety output)
F, 13, 14, 23, 24
Output voltage frequency range
45…65 Hz
Contact design
1 x de-energised to safe (NO contact), 1 x energised to safe (NO contact)
Contact base material
AgNi 0.15 gold flashed
Max. permitted switching voltage
250 V AC
Max. permitted switching current
5 A
Max. switching current, internal fuse
5 A (refer to derating curve)
Max. switching current, external fuse
5 A (refer to derating curve)
Max. switching capacity
1250 VA
Internal fuse
5 A time-lag
External back-up fuse
5 A time-lag
Short circuit resistance
No
Switch-on time
<5.5 ms (DTS), <5 ms (ETS)
Switch-off time
<4 ms (DTS), <4 ms (ETS)
Min. switching capacity
10 mA @ 12 V
Safety-related basic specifications
Device type
A
Hardware fault tolerance (HFT)
1
Safety category
SIL 3
Safety standard
DIN EN 61508
General data
Operating altitude
≤ 2000 m, above sea level
Rail
TS 35
Colour
black, yellow
Insulation coordination
Rated voltage
300 V
Pollution severity
2
Surge voltage category
III
Clearance and creepage distances for control side - load side
≥ 5.5 mm
Dielectric strength for control side - load side
4 kVeff / 1 min
Dielectric strength to mounting rail
4 kVeff / 1 Min.
Impulse withstand voltage
6 kV (1.2/50 µs)
Protection degree
IP20
Further details of approvals / standards
Standards
EN 61000, EN 61326-3-2
Connection data
Wire connection method
Screw connection
Stripping length, rated connection
8 mm
Tightening torque, min.
0.4 Nm
Tightening torque, max.
0.6 Nm
Clamping range, rated connection
1.5 mm²
Clamping range, min.
0.13 mm²
Clamping range, max.
2.5 mm²
Wire connection cross section AWG, min.
AWG 26
Wire connection cross section AWG, max.
AWG 12
Wire cross-section, solid, min.
0.2 mm²
Wire cross-section, solid, max.
2.5 mm²
Wire connection cross section, finely stranded, min.
0.2 mm²
Wire connection cross section, finely stranded, max.
2.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.
0.2 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.
2.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.
0.2 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.
2.5 mm²
Blade size
size PH0
Classifications
ETIM 6.0
EC001449
ETIM 7.0
EC001449
ETIM 8.0
EC001449
ETIM 9.0
EC001449
ECLASS 9.0
27-37-18-19
ECLASS 9.1
27-37-18-19
ECLASS 10.0
27-37-18-19
ECLASS 11.0
27-37-18-19
ECLASS 12.0
27-37-18-19
ECLASS 13.0
27-37-18-19
Approvals
Approvals
ROHS
Conform
There are no products in this group.
Version
SAFESERIES, Safety relay,24 V DC -15 / +20%, 35 mA , Max. switching current, internal fuse : 5 A (refer to derating curve), SIL 3, DIN EN 61508
Order No.
1319270000
Type
SCS 24VDC P2SIL3DSES
GTIN (EAN)
4050118125115
Qty.
1 pc(s).
Depth
114.1 mm
Depth (inches)
4.492 inch
Height
117.3 mm
Height (inches)
4.618 inch
Width
22.5 mm
Width (inches)
0.886 inch
Net weight
200 g
Storage temperature
-40 °C...85 °C
Operating temperature
-25 °C...50 °C
Humidity
40 °C / 93 % rel. humidity, no condensation
REACH SVHC
Lead 7439-92-1
SCIP
807f1906-ce90-4f93-8801-4b128b343e6b
Connection designation (safety circuit)
A1, A2
Rated control voltage
24 V DC -15 / +20%
Current consumption
45 mA
Guaranteed current consumption of 24 VDC -10%
35 mA
Inrush current
≤ 80 mA / 40 ms
Pull-in/drop-out voltage DC coil
17 V / 12.5 V (DTS)
Status indicator
LED yellow
Protective circuit
Rectifier
Connection designation (safety test)
X1, X2, X3
Rated control voltage
24 V DC
Number of test inputs
2
Status indicator
LED red flashing: test input is triggered
Connection designation (safety output)
F, 13, 14, 23, 24
Output voltage frequency range
45…65 Hz
Contact design
1 x de-energised to safe (NO contact), 1 x energised to safe (NO contact)
Contact base material
AgNi 0.15 gold flashed
Max. permitted switching voltage
250 V AC
Max. permitted switching current
5 A
Max. switching current, internal fuse
5 A (refer to derating curve)
Max. switching current, external fuse
5 A (refer to derating curve)
Max. switching capacity
1250 VA
Internal fuse
5 A time-lag
External back-up fuse
5 A time-lag
Short circuit resistance
No
Switch-on time
<5.5 ms (DTS), <5 ms (ETS)
Switch-off time
<4 ms (DTS), <4 ms (ETS)
Min. switching capacity
10 mA @ 12 V
Device type
A
Hardware fault tolerance (HFT)
1
Safety category
SIL 3
Safety standard
DIN EN 61508
Operating altitude
≤ 2000 m, above sea level
Rail
TS 35
Colour
black, yellow
Rated voltage
300 V
Pollution severity
2
Surge voltage category
III
Clearance and creepage distances for control side - load side
≥ 5.5 mm
Dielectric strength for control side - load side
4 kVeff / 1 min
Dielectric strength to mounting rail
4 kVeff / 1 Min.
Impulse withstand voltage
6 kV (1.2/50 µs)
Protection degree
IP20
Standards
EN 61000, EN 61326-3-2
Wire connection method
Screw connection
Stripping length, rated connection
8 mm
Tightening torque, min.
0.4 Nm
Tightening torque, max.
0.6 Nm
Clamping range, rated connection
1.5 mm²
Clamping range, min.
0.13 mm²
Clamping range, max.
2.5 mm²
Wire connection cross section AWG, min.
AWG 26
Wire connection cross section AWG, max.
AWG 12
Wire cross-section, solid, min.
0.2 mm²
Wire cross-section, solid, max.
2.5 mm²
Wire connection cross section, finely stranded, min.
0.2 mm²
Wire connection cross section, finely stranded, max.
2.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.
0.2 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.
2.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.
0.2 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.
2.5 mm²
Blade size
size PH0
ETIM 6.0
EC001449
ETIM 7.0
EC001449
ETIM 8.0
EC001449
ETIM 9.0
EC001449
ECLASS 9.0
27-37-18-19
ECLASS 9.1
27-37-18-19
ECLASS 10.0
27-37-18-19
ECLASS 11.0
27-37-18-19
ECLASS 12.0
27-37-18-19
ECLASS 13.0
27-37-18-19
Approvals
ROHS
Conform
There are no products in this group.
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.