WAZ5 VVC 0-10V/0-10V   Do not use product for new developmentsOnly remaining stock available
         

Icon
Icon
Icon
Icon
 

General ordering data

Version Signal converter/insulator, Input : 0-10 V, Output : 0-10 V
Order No. 8540340000
Type WAZ5 VVC 0-10V/0-10V
GTIN (EAN) 4032248180721
Qty. 1 pc(s).
Delivery status This article will no longer be available in the future.
Available until 2023-12-30
Alternative product 2456860000

Dimensions and weights

Depth 112.4 mm
Depth (inches) 4.425 inch
Width 17.5 mm
Width (inches) 0.689 inch
Length 92.4 mm
Length (inches) 3.638 inch
Net weight 124 g

Temperatures

Storage temperature -20 °C...85 °C
Operating temperature 0 °C...70 °C
Humidity at operating temperature 0...95 % (no condensation)

Probability of failure

SIL in compliance with IEC 61508 None
MTTF 463 a

Environmental Product Compliance

REACH SVHC Lead 7439-92-1
SCIP 94561991-a963-4084-a5f3-dfa3a5c2a27e

Input

Input resistance, voltage typ. 100 kΩ
Input voltage 0...10 V
Number of inputs 1

Output

Cut-off frequency (-3 dB) 10 Hz
Load impedance current ≤ 600 Ω
Number of outputs 1
Output voltage, note 0...10 V
load impedance voltage ≥ 1 kΩ

Output (digital)

Max. switching voltage, AC 0 V
Rated switching current 0.1 A

General data

Accuracy 0.2 %
Configuration none
Galvanic isolation 3-way isolator
Power consumption <1.3 W @ IOUT = 5 mA
Rail TS 35
Step response time ≤ 45 ms
Temperature coefficient ± 250 ppm/K
Voltage supply 24 V DC ± 25 %

Insulation coordination

EMC standards EN 55011, EN 61000-6
Galvanic isolation 3-way isolator
Impulse withstand voltage 4 kV
Insulation voltage 2 kVeff / 5 s
Insulation voltage input or output/rail 4 kVeff / 1 min.
Insulation voltage input or output/supply 2 kVeff / 5 s
Pollution severity 2
Rated voltage 300 V
Surge voltage category III

Connection data

Type of connection Tension-clamp connection
Stripping length, rated connection 7 mm
Clamping range, rated connection 1.5 mm²
Clamping range, min. 0.5 mm²
Clamping range, max. 2.5 mm²

Important note

Product information This product will soon be replaced by a new product.
Please do not use with new systems. Please contact our technical support.

Downloads

Approval/Certificate/Document of Conformity
Engineering Data
Eplan Data Portal Eplan data
CADENAS eCATALOG CAX data
WSCAD Universe WSCAD data
User Documentation
Catalogues Catalogues in PDF-format
Brochures

Classifications

ETIM 6.0 EC002653
ETIM 7.0 EC002653
ETIM 8.0 EC002653
ETIM 9.0 EC002653
ECLASS 9.0 27-21-01-20
ECLASS 9.1 27-21-01-20
ECLASS 10.0 27-21-01-20
ECLASS 11.0 27-21-01-20
ECLASS 12.0 27-21-01-20
ECLASS 13.0 27-21-01-20

Tender specification sheets

Long specification

Standard signal isolating converter
1-channel signal isolating converter in 17.5 mm width, with external power supply,
to transmit and isolate analogue DC current signals from 0 to 10 V

Add-on housing for TS35 rail mounting
Dimensions: L/W/H 92.4/ 17.5/ 112.4 mm
Tension-clamp connection / Nominal cross-section 1.5 mm2
Protection degree: IP 20  


Input                         0...10 V

Output                                             0...10 V
Transmission error             < 0,2% v. E. 
Limit frequency 10 Hz
Auxiliary power                                     24 VDC +/- 25 %
Power loss approx. 1.3 W
Ambient
temperature range 0 °C...+55 °C

Secure isolation                   EN 50178, 3-way isolation up to 4 kV AC/DC of all circuits against each other
Test voltage                               4 kV input against output against auxiliary power
Rated
voltage                                        
 300 V AC/DC at overvoltage category III and pollution degree 2
Approvals cULus










Type                                                             WAZ5 VVC 0-10/0-10V

Short specification Standard signal isolating converter 1-channel signal isolating converter in 17.5 mm width, with external power supply, for transmitting and isolating analogue DC current signals from 0 to 10 V

Approvals

Approvals CE CULUS
ROHS Conform
UL File Number Search UL Website
Certificate no. (cULus) E141197

Related products

Type of connection: Tension-clamp connection
Order No.: 8447140000
Type: WAZ4 VVC DC 0-10/0-10V
Version:
Signal converter/insulator, Input : 0-10 V, Output : 0-10 V
Delivery status:
This article will no longer be available in the future.
 
Type of connection: Tension-clamp connection
Order No.: 8445050000
Type: WAZ4 CVC DC 4-20/0-10V
Version:
Signal converter/insulator, Input : 4-20 mA, Output : 0-10 V
Delivery status:
This article will no longer be available in the future.
 
Type of connection: Tension-clamp connection
Order No.: 8540300000
Type: WAZ5 VCC 0-10V/4-20MA
Version:
Signal converter/insulator, Input : 0-10 V, Output : 4-20 mA
Delivery status:
This article will no longer be available in the future.
 
Contact
Weidmüller Interface GmbH & Co. KG
 
+49 5231 14-0
+49 5231 14-292083
More information
Decentralised automation solutions
Energy Management Solutions
Industrial Analytics
Industrial IoT Solutions
More information
Mobility Concepts
Photovoltaics
Wind Solutions
Workplace Solutions
More information
Single Pair Ethernet
Weidmüller Configurator
Support & Service
Contact
Disposal Instructions
Engineering data
Repairs and replacement parts