Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Terminal Blocks
Connectors
PCB Terminals and Connectors
Enclosure Systems and Components
Contactless Connectivity
Cable Entry Systems and Components
Cord sets, Patchcords and Cables
PLC Interfaces and Migration Solutions
Service Interfaces
Distribution Boxes
Signal distribution boxes
Power distribution boxes
EX ia distribution boxes
FieldPower® Power bus distributor
Elevator Shaft Wiring
Power bus distributor
Connection box for MP-Bus Belimo
IP 30
IP 65
IP 65 with fused outgoing circuit
IP 65 with maintenance switch
IP 65 with maintenance switch and fused outlet
General ordering data
Version
FieldPower® power distribution box, 3-phase AC, IP65, glass-fibre reinforced polycarbonate, Insulation displacement connection (IDC), PUSH IN, Maintenance switch
Order No.
8000028513
Type
FP BOX ON/OFF16A FUSE R
GTIN (EAN)
4050118505368
Qty.
1 pc(s).
Dimensions and weights
Depth
165 mm
Depth (inches)
6.496 inch
Height
181 mm
Height (inches)
7.126 inch
Width
192 mm
Width (inches)
7.559 inch
Net weight
1,593 g
Temperatures
Storage temperature
-25 °C...55 °C
Ambient temperature
-25 °C...+45 °C
Operating temperature
-25 °C...45 °C
Environmental Product Compliance
REACH SVHC
Lead 7439-92-1, Potassium perfluorobutane sulfonate 29420-49-3
SCIP
7645f3b1-6db9-495d-9e21-ab1d894aff05
Clamping capacity
Connection data - contact element power bus
Wire connection method
Insulation displacement connection (IDC)
Blade size of operating tool
0.6 x 3.5 mm
Number of poles
5
Conductor connection cross-section, solid, max.
6 mm²
Conductor connection cross-section, solid, min.
1.5 mm²
Conductor connection cross-section, stranded, max.
6 mm²
Conductor connection cross-section, stranded, min.
2.5 mm²
Conductor connection cross-section, finely stranded, max.
6 mm²
Conductor connection cross-section, finely stranded, min.
2.5 mm²
Conductor connection cross-section, finest stranded, max.
6 mm²
Conductor connection cross-section, finest stranded, min.
2.5 mm²
Connection data - contact element Branch / Feed-in
Wire connection method
PUSH IN
Blade size of operating tool
0.6 x 3.5 mm
Stripping length
14 mm
Number of poles
5
Conductor connection cross-section, solid, max.
6 mm²
Conductor connection cross-section, solid, min.
0.5 mm²
Conductor connection cross-section, stranded, max.
6 mm²
Conductor connection cross-section, stranded, min.
0.5 mm²
Conductor connection cross-section, finely stranded, max.
10 mm²
Conductor connection cross-section, finely stranded, min.
0.5 mm²
Conductor connection cross-section, finest stranded, max.
6 mm²
Conductor connection cross-section, finest stranded, min.
0.5 mm²
Conductor connection cross-section with wire end ferrule
Type of wire end ferrule
12 mm with plastic collar
Standard
DIN 46228/1
Cross-section, min.
0.5 mm²
Cross-section, max.
6 mm²
Type of wire end ferrule
12 mm with plastic collar
Standard
DIN 46228/4
Cross-section, min.
0.5 mm²
Cross-section, max.
6 mm²
Type of wire end ferrule
8 mm with plastic collar
Standard
DIN 46228/1
Cross-section, min.
0.5 mm²
Cross-section, max.
6 mm²
Type of wire end ferrule
8 mm with plastic collar
Standard
DIN 46228/4
Cross-section, min.
0.5 mm²
Cross-section, max.
6 mm²
Type of wire end ferrule
Twin wire-end ferrules
Cross-section, min.
0.5 mm²
Cross-section, max.
6 mm²
Connection data - plug-in connector
Wire connection method
PUSH IN
Blade size of operating tool
3.0 x 0.5 mm
Stripping length
12 mm
Number of poles
5
Conductor connection cross-section, solid, max.
4 mm²
Conductor connection cross-section, solid, min.
0.5 mm²
Conductor connection cross-section, stranded, max.
4 mm²
Conductor connection cross-section, stranded, min.
0.5 mm²
Conductor connection cross-section, finely stranded, max.
4 mm²
Conductor connection cross-section, finely stranded, min.
0.5 mm²
Conductor connection cross-section, finest stranded, max.
4 mm²
Conductor connection cross-section, finest stranded, min.
0.5 mm²
Conductor connection cross-section with wire end ferrule
Type of wire end ferrule
12 mm with plastic collar
Standard
DIN 46228/1
Cross-section, min.
0.5 mm²
Cross-section, max.
4 mm²
Type of wire end ferrule
12 mm with plastic collar
Standard
DIN 46228/4
Cross-section, min.
0.5 mm²
Cross-section, max.
4 mm²
Type of wire end ferrule
8 mm with plastic collar
Standard
DIN 46228/1
Cross-section, min.
0.5 mm²
Cross-section, max.
4 mm²
Type of wire end ferrule
8 mm with plastic collar
Standard
DIN 46228/4
Cross-section, min.
0.5 mm²
Cross-section, max.
4 mm²
Type of wire end ferrule
Twin wire-end ferrules
Cross-section, min.
0.5 mm²
Cross-section, max.
4 mm²
General data
Insulating material
Polycarbonate
Enclosure material
glass-fibre reinforced polycarbonate
Silicone
No
Colour
black
Protection degree
IP65
UL 94 flammability rating
5VA
Torque for lid screws
2 Nm
Lid attachment
TX20 screws
lockable
Yes
Type of mounting
Screw mounting, Fixing lugs
Installation advice
Lid screws included
Function
Maintenance switch
With cable gland
Yes
Can be coded
Yes, Coded on PE
Voltage type
3-phase AC
Number of poles
5
Number of connections / pole
1
Wire connection method
Insulation displacement connection (IDC), PUSH IN
Type of connection, signal
M12, A-coded
Cartridge fuse
10 x 38 mm
Conductor outlet direction
90°
Failure indicator
Red LED
Fuse holder (cartridge holder)
Pivoting
Rated data acc. to IEC
Rated data acc. to IEC for contact element
Voltage type
AC
Number of phases
3
Standard
IEC 60947-7-1, IEC 60947-7-2
Rated voltage
800 V
Rated impulse withstand voltage
8 kV
Rated current (3 loaded poles)
41 A
Rated current (4 loaded poles)
25 A
Rated data acc. to IEC for fuse plug
Voltage type
AC
Number of phases
3
Standard
IEC 61984, IEC 60947-7-3
Rated voltage
500 V
Rated impulse withstand voltage
6 kV
Rated current
12 A
Rated data acc. to IEC for plug-in connector
Voltage type
AC
Number of phases
3
Standard
IEC 60947-7-1, IEC 60947-7-2, IEC 61984
Rated voltage
690 V
Rated impulse withstand voltage
8 kV
Rated current (3 loaded poles)
32 A
Rated current (4 loaded poles)
25 A
Rated data acc. to UL
Rated data acc. to UL for contact element
Standard
UL 1059
Note
for use with UL-listed TC-ER cables
Conductor connection cross-section, AWG, max.
AWG 10
Conductor connection cross-section, AWG, min.
AWG 14
Rated voltage
600 V
Rated current
30 A
Rated data acc. to UL for fuse plug
Rated data acc. to UL for plug-in connector
Standard
UL 1059
Note
for use with UL-listed TC-ER cables
Conductor connection cross-section, AWG, max.
AWG 12
Conductor connection cross-section, AWG, min.
AWG 16
Rated voltage
600 V
Rated current
20 A
Standards
not UL approved
Technical data Switch
Clamping range, plug, max.
10 mm²
Clamping range, plug, min.
0.75 mm²
Operating voltage
400 V
Pollution severity
3
Power rating AC-23A
7.5 kW
Rated current AC-23A
16 A
Switch according to standard
IEC 60947-3
Switch type
ABB OT16FT3
Terminals - torque
0.8 Nm
Wire connection cross section AWG, max.
AWG 8
Wire connection cross section AWG, min.
AWG 18
auxiliary contact
ABB OA1G10
Classifications
ETIM 6.0
EC000214
ETIM 7.0
EC000214
ETIM 8.0
EC000214
ETIM 9.0
EC000214
ECLASS 9.0
27-14-24-09
ECLASS 9.1
27-14-24-09
ECLASS 10.0
27-14-24-09
ECLASS 11.0
27-14-24-09
ECLASS 12.0
27-14-24-09
ECLASS 13.0
27-14-24-09
There are no products in this group.
Version
FieldPower® power distribution box, 3-phase AC, IP65, glass-fibre reinforced polycarbonate, Insulation displacement connection (IDC), PUSH IN, Maintenance switch
Order No.
8000028513
Type
FP BOX ON/OFF16A FUSE R
GTIN (EAN)
4050118505368
Qty.
1 pc(s).
Depth
165 mm
Depth (inches)
6.496 inch
Height
181 mm
Height (inches)
7.126 inch
Width
192 mm
Width (inches)
7.559 inch
Net weight
1,593 g
Storage temperature
-25 °C...55 °C
Ambient temperature
-25 °C...+45 °C
Operating temperature
-25 °C...45 °C
REACH SVHC
Lead 7439-92-1, Potassium perfluorobutane sulfonate 29420-49-3
SCIP
7645f3b1-6db9-495d-9e21-ab1d894aff05
Connection data - contact element power bus
Wire connection method
Insulation displacement connection (IDC)
Blade size of operating tool
0.6 x 3.5 mm
Number of poles
5
Conductor connection cross-section, solid, max.
6 mm²
Conductor connection cross-section, solid, min.
1.5 mm²
Conductor connection cross-section, stranded, max.
6 mm²
Conductor connection cross-section, stranded, min.
2.5 mm²
Conductor connection cross-section, finely stranded, max.
6 mm²
Conductor connection cross-section, finely stranded, min.
2.5 mm²
Conductor connection cross-section, finest stranded, max.
6 mm²
Conductor connection cross-section, finest stranded, min.
2.5 mm²
Connection data - contact element Branch / Feed-in
Wire connection method
PUSH IN
Blade size of operating tool
0.6 x 3.5 mm
Stripping length
14 mm
Number of poles
5
Conductor connection cross-section, solid, max.
6 mm²
Conductor connection cross-section, solid, min.
0.5 mm²
Conductor connection cross-section, stranded, max.
6 mm²
Conductor connection cross-section, stranded, min.
0.5 mm²
Conductor connection cross-section, finely stranded, max.
10 mm²
Conductor connection cross-section, finely stranded, min.
0.5 mm²
Conductor connection cross-section, finest stranded, max.
6 mm²
Conductor connection cross-section, finest stranded, min.
0.5 mm²
Conductor connection cross-section with wire end ferrule
Type of wire end ferrule
12 mm with plastic collar
Standard
DIN 46228/1
Cross-section, min.
0.5 mm²
Cross-section, max.
6 mm²
Type of wire end ferrule
12 mm with plastic collar
Standard
DIN 46228/4
Cross-section, min.
0.5 mm²
Cross-section, max.
6 mm²
Type of wire end ferrule
8 mm with plastic collar
Standard
DIN 46228/1
Cross-section, min.
0.5 mm²
Cross-section, max.
6 mm²
Type of wire end ferrule
8 mm with plastic collar
Standard
DIN 46228/4
Cross-section, min.
0.5 mm²
Cross-section, max.
6 mm²
Type of wire end ferrule
Twin wire-end ferrules
Cross-section, min.
0.5 mm²
Cross-section, max.
6 mm²
Connection data - plug-in connector
Wire connection method
PUSH IN
Blade size of operating tool
3.0 x 0.5 mm
Stripping length
12 mm
Number of poles
5
Conductor connection cross-section, solid, max.
4 mm²
Conductor connection cross-section, solid, min.
0.5 mm²
Conductor connection cross-section, stranded, max.
4 mm²
Conductor connection cross-section, stranded, min.
0.5 mm²
Conductor connection cross-section, finely stranded, max.
4 mm²
Conductor connection cross-section, finely stranded, min.
0.5 mm²
Conductor connection cross-section, finest stranded, max.
4 mm²
Conductor connection cross-section, finest stranded, min.
0.5 mm²
Conductor connection cross-section with wire end ferrule
Type of wire end ferrule
12 mm with plastic collar
Standard
DIN 46228/1
Cross-section, min.
0.5 mm²
Cross-section, max.
4 mm²
Type of wire end ferrule
12 mm with plastic collar
Standard
DIN 46228/4
Cross-section, min.
0.5 mm²
Cross-section, max.
4 mm²
Type of wire end ferrule
8 mm with plastic collar
Standard
DIN 46228/1
Cross-section, min.
0.5 mm²
Cross-section, max.
4 mm²
Type of wire end ferrule
8 mm with plastic collar
Standard
DIN 46228/4
Cross-section, min.
0.5 mm²
Cross-section, max.
4 mm²
Type of wire end ferrule
Twin wire-end ferrules
Cross-section, min.
0.5 mm²
Cross-section, max.
4 mm²
Insulating material
Polycarbonate
Enclosure material
glass-fibre reinforced polycarbonate
Silicone
No
Colour
black
Protection degree
IP65
UL 94 flammability rating
5VA
Torque for lid screws
2 Nm
Lid attachment
TX20 screws
lockable
Yes
Type of mounting
Screw mounting, Fixing lugs
Installation advice
Lid screws included
Function
Maintenance switch
With cable gland
Yes
Can be coded
Yes, Coded on PE
Voltage type
3-phase AC
Number of poles
5
Number of connections / pole
1
Wire connection method
Insulation displacement connection (IDC), PUSH IN
Type of connection, signal
M12, A-coded
Cartridge fuse
10 x 38 mm
Conductor outlet direction
90°
Failure indicator
Red LED
Fuse holder (cartridge holder)
Pivoting
Rated data acc. to IEC for contact element
Voltage type
AC
Number of phases
3
Standard
IEC 60947-7-1, IEC 60947-7-2
Rated voltage
800 V
Rated impulse withstand voltage
8 kV
Rated current (3 loaded poles)
41 A
Rated current (4 loaded poles)
25 A
Rated data acc. to IEC for fuse plug
Voltage type
AC
Number of phases
3
Standard
IEC 61984, IEC 60947-7-3
Rated voltage
500 V
Rated impulse withstand voltage
6 kV
Rated current
12 A
Rated data acc. to IEC for plug-in connector
Voltage type
AC
Number of phases
3
Standard
IEC 60947-7-1, IEC 60947-7-2, IEC 61984
Rated voltage
690 V
Rated impulse withstand voltage
8 kV
Rated current (3 loaded poles)
32 A
Rated current (4 loaded poles)
25 A
Rated data acc. to UL for contact element
Standard
UL 1059
Note
for use with UL-listed TC-ER cables
Conductor connection cross-section, AWG, max.
AWG 10
Conductor connection cross-section, AWG, min.
AWG 14
Rated voltage
600 V
Rated current
30 A
Rated data acc. to UL for fuse plug
Rated data acc. to UL for plug-in connector
Standard
UL 1059
Note
for use with UL-listed TC-ER cables
Conductor connection cross-section, AWG, max.
AWG 12
Conductor connection cross-section, AWG, min.
AWG 16
Rated voltage
600 V
Rated current
20 A
Standards
not UL approved
Clamping range, plug, max.
10 mm²
Clamping range, plug, min.
0.75 mm²
Operating voltage
400 V
Pollution severity
3
Power rating AC-23A
7.5 kW
Rated current AC-23A
16 A
Switch according to standard
IEC 60947-3
Switch type
ABB OT16FT3
Terminals - torque
0.8 Nm
Wire connection cross section AWG, max.
AWG 8
Wire connection cross section AWG, min.
AWG 18
auxiliary contact
ABB OA1G10
ETIM 6.0
EC000214
ETIM 7.0
EC000214
ETIM 8.0
EC000214
ETIM 9.0
EC000214
ECLASS 9.0
27-14-24-09
ECLASS 9.1
27-14-24-09
ECLASS 10.0
27-14-24-09
ECLASS 11.0
27-14-24-09
ECLASS 12.0
27-14-24-09
ECLASS 13.0
27-14-24-09
There are no products in this group.
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.