ACT20P-VM-AO-S
         

Icon
Icon
Icon
Icon
Icon
Icon
 

General ordering data

Version Signal converter/insulator, Input : AC/DC voltage, 0...600 V DC, 0…440 V AC, Output : 0-10 V, 0(4)-20 mA, Signal converter/isolator
Order No. 7760054306
Type ACT20P-VM-AO-S
GTIN (EAN) 6944169749087
Qty. 1 pc(s).

Dimensions and weights

Depth 114.3 mm
Depth (inches) 4.5 inch
Height 119.2 mm
Height (inches) 4.693 inch
Width 22.5 mm
Width (inches) 0.886 inch
Net weight 110 g

Temperatures

Storage temperature -40 °C...85 °C
Operating temperature -20 °C...60 °C
Humidity at operating temperature 0...95 % (no condensation)
Humidity 5...95 %, no condensation

Probability of failure

SIL in compliance with IEC 61508 None
MTTF 140 a

Environmental Product Compliance

REACH SVHC Lead 7439-92-1
SCIP 2f6dd957-421a-46db-a0c2-cf1609156924

Input

Input resistance 1 MΩ±5%
Input signal UDC, UACEffective value (sinusoidal only) 40-60 Hz
Input voltage 0…30 V DC, 0…60 V DC, 0…150 V DC, 0…300 V DC, 0…440 V DC, 0…660 V DC, 0…60 V AC, 0…144 V AC, 0…300 V AC, 0…440 V AC, configurable
Number of inputs 1

Output

Load impedance current ≤ 500 Ω
Number of outputs 1
Output current 0...20 mA, 4...20 mA
Output voltage, note 0...10 V
Type active, connected control must be passive
load impedance voltage ≥ 10 kΩ

Output (analogue)

Output current 0...20 mA, 4...20 mA

General data

Accuracy 0.5 % FSR
Configuration With FDT/DTM software, Requires configuration adapter 8978580000 CBX200 USB
Galvanic isolation 3-way isolator, between input ⁄ output ⁄ supply
Power consumption ≤ 100 mA @ 24 VDC, ≤ 120mA @ 24V AC
Rail TS 35
Step response time <300 ms
Temperature coefficient ≤ 200 ppm/K
Voltage supply 24…240 VUC (±10%)

Insulation coordination

EMC standards EN 61326-1, EN 61000-6-2, EN 61000-6-4
Galvanic isolation 3-way isolator, between input ⁄ output ⁄ supply
Impulse withstand voltage 4 kV (1.2/50 μs) input - output, 4 kV (1.2/50 μs) input / supply, 2.5 kV (1.2/50 μs) output / supply
Insulation voltage 1.5 kV AC output / supply, 2 kV AC input / output, 2 kV AC input / supply
Pollution severity 2
Rated voltage 600 V input / output, 600 V input / supply, 300 V output / supply
Surge voltage category III

Connection data

Type of connection Screw connection
Tightening torque, min. 0.4 Nm
Tightening torque, max. 0.6 Nm
Clamping range, rated connection 1.5 mm²
Clamping range, min. 0.5 mm²
Clamping range, max. 2.5 mm²
Wire connection cross section AWG, min. AWG 26
Wire connection cross section AWG, max. AWG 12

Important note

Product information The analogue voltage converter ACT20P-VM-AO-S measures DC or AC voltages. The analogue input signal is linearly converted into an analogue output signal (current or voltage) and galvanically isolated.

Features
  • Configuration and monitoring are performed via FDT/DTM-Software „WI-Manager“.
  • Signal and alarm triggering upon exceeding limit values or reverse polarity DC input voltage
  • Front LED indicates operation status
  • 3-way galvanic isolation between input, output and power supply.

Downloads

Classifications

ETIM 6.0 EC002653
ETIM 7.0 EC002653
ETIM 8.0 EC002653
ETIM 9.0 EC002653
ECLASS 9.0 27-21-01-20
ECLASS 9.1 27-21-01-20
ECLASS 10.0 27-21-01-20
ECLASS 11.0 27-21-01-20
ECLASS 12.0 27-21-01-20
ECLASS 13.0 27-21-01-20

Approvals

Approvals CE CURUS
ROHS Conform
UL File Number Search UL Website
Certificate No. (cURus) E469563

Related products

Type of connection: Screw connection
Order No.: 7760054114
Type: ACT20P-CI-CO-S
Version:
Signal converter/insulator, Input : 0(4)-20 mA, Output : 0(4)-20 mA, Signal converter/isolator, HART®
 
Type of connection: PUSH IN
Order No.: 2489680000
Type: ACT20P-CI-CO-P
Version:
Signal converter/insulator, Input : 0(4)-20 mA, Output : 0(4)-20 mA, Signal converter/isolator, HART®
 
Type of connection: Screw connection
Order No.: 1506200000
Type: ACT20P-CI-CO-P-S
Version:
Signal converter/insulator, Input : 0(4)-20 mA, Output : 0(4)-20 mA, Voltage supply also via CH20M rail bus, Signal converter/isolator, HART®
 
Type of connection: PUSH IN
Order No.: 2514620000
Type: ACT20P-CI-CO-P-P
Version:
Signal converter/insulator, Input : 0(4)-20 mA, Output : 0(4)-20 mA, Voltage supply also via CH20M rail bus, Signal converter/isolator, HART®
 
Type of connection: Screw connection
Order No.: 7760054117
Type: ACT20P-2CI-2CO-12-S
Version:
Signal converter/insulator, Input : 2 x 0(4) - 20 mA, Output : 2 x 4-20 mA, Signal converter/isolator, HART®
 
Type of connection: PUSH IN
Order No.: 2489730000
Type: ACT20P-2CI-2CO-12-P
Version:
Signal converter/insulator, Input : 2 x 0(4) - 20 mA, Output : 2 x 4-20 mA, Signal converter/isolator, HART®
 
Type of connection: PUSH IN
Order No.: 2514650000
Type: ACT20P-2CI-2CO-12-P-P
Version:
Signal converter/insulator, Input : 2 x 0(4) - 20 mA, Output : 0(4)-20 mA, Voltage supply also via CH20M rail bus, Signal converter/isolator, HART®
 
Type of connection: Screw connection
Order No.: 1506210000
Type: ACT20P-2CI-2CO-12P-S
Version:
Signal converter/insulator, Input : 2 x 0(4) - 20 mA, Output : 0(4)-20 mA, Voltage supply also via CH20M rail bus, Signal converter/isolator, HART®
 
Type of connection: Screw connection
Order No.: 1540010000
Type: ACT20P-CI-VO-S
Version:
Signal converter/insulator, Input : 0(4)-20 mA, Output : 0-10 V, Signal converter/isolator
 
Type of connection: PUSH IN
Order No.: 2489740000
Type: ACT20P-CI-VO-P
Version:
Signal converter/insulator, Input : 0(4)-20 mA, Output : 0-10 V, Signal converter/isolator
 
Type of connection: Screw connection
Order No.: 1537750000
Type: ACT20P-CI-VO-P-S
Version:
Signal converter/insulator, Input : 0(4)-20 mA, Output : 0-10 V, Voltage supply also via CH20M rail bus, Signal converter/isolator
 
Type of connection: PUSH IN
Order No.: 2514640000
Type: ACT20P-CI-VO-P-P
Version:
Signal converter/insulator, Input : 0(4)-20 mA, Output : 0-10 V, Voltage supply also via CH20M rail bus, Signal converter/isolator
 
Type of connection: Screw connection
Order No.: 7760054131
Type: ACT20P-VI3-VO3-S
Version:
Signal converter/insulator, Input : -10…0…+10 V, Output : -10…0…+10 V, Signal converter/isolator
 
Type of connection: PUSH IN
Order No.: 7760054360
Type: ACT20P-VM-AO-P
Version:
Signal converter/insulator, Input : AC/DC voltage, 0...600 V DC, 0…440 V AC, Output : 0-10 V, 0(4)-20 mA, Signal converter/isolator
 
Contact
Weidmüller Interface GmbH & Co. KG
 
+49 5231 14-0
+49 5231 14-292083
More information
Decentralised automation solutions
Energy Management Solutions
Industrial Analytics
Industrial IoT Solutions
More information
Mobility Concepts
Photovoltaics
Wind Solutions
Workplace Solutions
More information
Single Pair Ethernet
Weidmüller Configurator
Support & Service
Contact
Disposal Instructions
Engineering data
Repairs and replacement parts