Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Analogue Signal Conditioning
Power Supplies
Electronics Housings
Lightning and Surge Protection
e-mobility
Photovoltaics
Fieldbus Distributors
Network-compatible current measuring transducers ACT20C
intrinsically safe signal converter - ACT20X
signal converter and process monitoring - ACT20P
Space-saving signal converter - ACT20M
Signal converter in terminal block format - MCZ
Compact standard signal isolators - PicoPak
Signal - & serial interface converter– WAVESERIES
Process monitoring displays
Analogue-digital / digital-analogue converter
Configuration software
Accessories
Signal converters
Passive isolator
Signal splitter
Temperature transducer
Measuring and monitoring relay
Current measuring transducer
Bridge measuring transducer
Frequency converters
Universal
General ordering data
Version
Limit value monitoring, Input : 180…500 V AC, Output : 2 x relays, Input: 3-phase voltage, Relay output
Order No.
7760054165
Type
ACT20P-VMR-3PH-ILP-H-S
GTIN (EAN)
6944169689086
Qty.
1 pc(s).
Dimensions and weights
Depth
114.3 mm
Depth (inches)
4.5 inch
Height
117 mm
Height (inches)
4.606 inch
Width
22.5 mm
Width (inches)
0.886 inch
Net weight
233 g
Temperatures
Storage temperature
-40 °C...85 °C
Operating temperature
-20 °C...65 °C
Humidity at operating temperature
0...95 % (no condensation)
Humidity
5...85 % rel. humidity, no condensation
Probability of failure
SIL in compliance with IEC 61508
None
Environmental Product Compliance
REACH SVHC
Lead 7439-92-1
SCIP
2f6dd957-421a-46db-a0c2-cf1609156924
Input
Input frequency
40…60 Hz
Input measurement range
200…480 VAC
Input resistance, voltage
≥1,8MΩ
Input voltage
180…500 VAC
Number of inputs
1
Type
3-phase or 3-phase plus zero conductor, AC voltage
Output
Number of outputs
2
Output (digital)
Alarm function
Top and bottom limit values, window range, Holding function can be activated, Phase error, Phase sequence, Asymmetry, Alarm delay: 0…10 s
Hysteresis
5 % @ Phase asymmetry
Max. switching frequency
20 Hz
Max. switching voltage, AC
250 V
Max. switching voltage, DC
30 V
Number of digital outputs
2
Rated switching current
5 A
Switch-on delay
0…10 s, configurable
Switching thresholds
Adjustable, MIN = 50…100 % x URated input voltage (undervoltage alarm), MAX = 70…120 % x URated input voltage (overvoltage alarm)
Type
2 x 1 - or 1 x 2 changeover contact relay, Relay polarity can be inverted
General data
Accuracy
3 % *Urated voltage
Configuration
DIP switch and potentiometer
Galvanic isolation
2-way isolator, between input/output, yes, between input ⁄ output ⁄ supply
Long-term drift
0.1 % / 10.000 h
Power consumption
≤ 3VA, <2 W
Rail
TS 35
Repeat accuracy
2 % *Urated voltage
Step response time
≤ 100 ms
Temperature coefficient
350 ppm/K
Voltage supply
supplied from voltage measurement inputs
Insulation coordination
EMC standards
EN 61326-1
Galvanic isolation
2-way isolator, between input/output, yes, between input ⁄ output ⁄ supply
Impulse withstand voltage
6 kV (input - output), 4 kV (output 1- output 2), 1.2/50 µs
Insulation voltage
2.5 kV (input / output)
Pollution severity
2
Rated voltage
600 VAC (input - output), 300 VAC (output 1 - output 2)
Surge voltage category
III
Test voltage
0.5 kV
Connection data
Type of connection
Screw connection
Tightening torque, min.
0.4 Nm
Tightening torque, max.
0.6 Nm
Clamping range, rated connection
1.5 mm²
Clamping range, min.
0.5 mm²
Clamping range, max.
2.5 mm²
Wire connection cross section AWG, min.
AWG 26
Wire connection cross section AWG, max.
AWG 12
Important note
Product information
ACT20P-VMR-3PH-ILP-H is a three-phase voltage setpoint limit monitor relay (3-phase or 3-phase plus zero conductor).
The device is powered by the input measuring circuit. The device incorporates two separate relay outputs which trigger an alarm upon phase asymmetry, phase loss, phase sequence errors and phase angle errors and when exceeding or falling below preset voltage limit values. The alarm can also be set to trigger after an adjustable time delay.
Features
Supply from the input measuring circuit
Manual front-sided configuration via DIP switch, potentiometer and rotary switch
Various alarm functions: phase asymmetry, phase loss, phase sequence errors, phase angle errors, alarm delay, upper/lower limit value alarm, window alarm
Front LEDs indicates operation status and malfunction.
3-way galvanic isolation between input, output 1 and output 2.
Classifications
ETIM 6.0
EC002654
ETIM 7.0
EC002654
ETIM 8.0
EC002654
ETIM 9.0
EC002654
ECLASS 9.0
27-21-01-22
ECLASS 9.1
27-21-01-22
ECLASS 10.0
27-21-01-22
ECLASS 11.0
27-21-01-22
ECLASS 12.0
27-21-01-22
ECLASS 13.0
27-21-01-22
Approvals
Approvals
ROHS
Conform
UL File Number Search
UL Website
Certificate No. (cURus)
E469563
Type of connection:
Screw connection
Order No.:
7760054164
Type:
ACT20P-VMR-1PH-H-S
Version:
Limit value monitoring, Input : 110 / 240 / 400 V AC/DC, Output : 2 x relays, Input: single-phase voltage, Relay output
Type of connection:
Screw connection
Order No.:
7760054359
Type:
ACT20P-VMR-1PH-H-P
Version:
Limit value monitoring, Input : 110 / 240 / 400 V AC/DC, Output : 2 x relays, Input: single-phase voltage, Relay output
Type of connection:
PUSH IN
Order No.:
7760054361
Type:
ACT20P-VMR-3PH-ILP-H-P
Version:
Limit value monitoring, Input : 180…500 V AC, Output : 2 x relays, Input: 3-phase voltage, Relay output
Type of connection:
Screw connection
Order No.:
7760054305
Type:
ACT20P-TMR-RTI-S
Version:
Limit value monitoring, Input : Temperature, PT100, Output : 2 x relays, Signal converter/isolator
Type of connection:
PUSH IN
Order No.:
7760054352
Type:
ACT20P-TMR-RTI-P
Version:
Limit value monitoring, Input : Temperature, PT100, Output : 2 x relays, Signal converter/isolator
Type of connection:
Screw connection
Order No.:
7940045760
Type:
ACT20P-UI-2RCO-DC-S
Version:
Limit value monitoring, Input : universal U, I, R,ϑ, Output : 2 x relays, Input: temperature, R, U, I, Relay output, 24 V DC power supply
Type of connection:
PUSH IN
Order No.:
2456840000
Type:
ACT20P-UI-2RCO-DC-P
Version:
Limit value monitoring, Input : universal U, I, R,ϑ, Output : 2 x relays, Input: temperature, R, U, I, Relay output, 24 V DC power supply
Type of connection:
Screw connection
Order No.:
1238910000
Type:
ACT20P-UI-2RCO-AC-S
Version:
Limit value monitoring, Input : universal U, I, R,ϑ, Output : 2 x relays, Input: temperature, R, U, I, Relay output, 90…264 V AC power supply
Type of connection:
PUSH IN
Order No.:
2495690000
Type:
ACT20P-UI-2RCO-AC-P
Version:
Limit value monitoring, Input : universal U, I, R,ϑ, Output : 2 x relays, Input: temperature, R, U, I, Relay output, 90…264 V AC power supply
Version
Limit value monitoring, Input : 180…500 V AC, Output : 2 x relays, Input: 3-phase voltage, Relay output
Order No.
7760054165
Type
ACT20P-VMR-3PH-ILP-H-S
GTIN (EAN)
6944169689086
Qty.
1 pc(s).
Depth
114.3 mm
Depth (inches)
4.5 inch
Height
117 mm
Height (inches)
4.606 inch
Width
22.5 mm
Width (inches)
0.886 inch
Net weight
233 g
Storage temperature
-40 °C...85 °C
Operating temperature
-20 °C...65 °C
Humidity at operating temperature
0...95 % (no condensation)
Humidity
5...85 % rel. humidity, no condensation
SIL in compliance with IEC 61508
None
REACH SVHC
Lead 7439-92-1
SCIP
2f6dd957-421a-46db-a0c2-cf1609156924
Input frequency
40…60 Hz
Input measurement range
200…480 VAC
Input resistance, voltage
≥1,8MΩ
Input voltage
180…500 VAC
Number of inputs
1
Type
3-phase or 3-phase plus zero conductor, AC voltage
Alarm function
Top and bottom limit values, window range, Holding function can be activated, Phase error, Phase sequence, Asymmetry, Alarm delay: 0…10 s
Hysteresis
5 % @ Phase asymmetry
Max. switching frequency
20 Hz
Max. switching voltage, AC
250 V
Max. switching voltage, DC
30 V
Number of digital outputs
2
Rated switching current
5 A
Switch-on delay
0…10 s, configurable
Switching thresholds
Adjustable, MIN = 50…100 % x URated input voltage (undervoltage alarm), MAX = 70…120 % x URated input voltage (overvoltage alarm)
Type
2 x 1 - or 1 x 2 changeover contact relay, Relay polarity can be inverted
Accuracy
3 % *Urated voltage
Configuration
DIP switch and potentiometer
Galvanic isolation
2-way isolator, between input/output, yes, between input ⁄ output ⁄ supply
Long-term drift
0.1 % / 10.000 h
Power consumption
≤ 3VA, <2 W
Rail
TS 35
Repeat accuracy
2 % *Urated voltage
Step response time
≤ 100 ms
Temperature coefficient
350 ppm/K
Voltage supply
supplied from voltage measurement inputs
EMC standards
EN 61326-1
Galvanic isolation
2-way isolator, between input/output, yes, between input ⁄ output ⁄ supply
Impulse withstand voltage
6 kV (input - output), 4 kV (output 1- output 2), 1.2/50 µs
Insulation voltage
2.5 kV (input / output)
Pollution severity
2
Rated voltage
600 VAC (input - output), 300 VAC (output 1 - output 2)
Surge voltage category
III
Test voltage
0.5 kV
Type of connection
Screw connection
Tightening torque, min.
0.4 Nm
Tightening torque, max.
0.6 Nm
Clamping range, rated connection
1.5 mm²
Clamping range, min.
0.5 mm²
Clamping range, max.
2.5 mm²
Wire connection cross section AWG, min.
AWG 26
Wire connection cross section AWG, max.
AWG 12
Product information
ACT20P-VMR-3PH-ILP-H is a three-phase voltage setpoint limit monitor relay (3-phase or 3-phase plus zero conductor).
The device is powered by the input measuring circuit. The device incorporates two separate relay outputs which trigger an alarm upon phase asymmetry, phase loss, phase sequence errors and phase angle errors and when exceeding or falling below preset voltage limit values. The alarm can also be set to trigger after an adjustable time delay.
Features
Supply from the input measuring circuit
Manual front-sided configuration via DIP switch, potentiometer and rotary switch
Various alarm functions: phase asymmetry, phase loss, phase sequence errors, phase angle errors, alarm delay, upper/lower limit value alarm, window alarm
Front LEDs indicates operation status and malfunction.
3-way galvanic isolation between input, output 1 and output 2.
ETIM 6.0
EC002654
ETIM 7.0
EC002654
ETIM 8.0
EC002654
ETIM 9.0
EC002654
ECLASS 9.0
27-21-01-22
ECLASS 9.1
27-21-01-22
ECLASS 10.0
27-21-01-22
ECLASS 11.0
27-21-01-22
ECLASS 12.0
27-21-01-22
ECLASS 13.0
27-21-01-22
Approvals
ROHS
Conform
UL File Number Search
UL Website
Certificate No. (cURus)
E469563
Type of connection:
Screw connection
Order No.:
7760054164
Type:
ACT20P-VMR-1PH-H-S
Version:
Limit value monitoring, Input : 110 / 240 / 400 V AC/DC, Output : 2 x relays, Input: single-phase voltage, Relay output
Type of connection:
Screw connection
Order No.:
7760054359
Type:
ACT20P-VMR-1PH-H-P
Version:
Limit value monitoring, Input : 110 / 240 / 400 V AC/DC, Output : 2 x relays, Input: single-phase voltage, Relay output
Type of connection:
PUSH IN
Order No.:
7760054361
Type:
ACT20P-VMR-3PH-ILP-H-P
Version:
Limit value monitoring, Input : 180…500 V AC, Output : 2 x relays, Input: 3-phase voltage, Relay output
Type of connection:
Screw connection
Order No.:
7760054305
Type:
ACT20P-TMR-RTI-S
Version:
Limit value monitoring, Input : Temperature, PT100, Output : 2 x relays, Signal converter/isolator
Type of connection:
PUSH IN
Order No.:
7760054352
Type:
ACT20P-TMR-RTI-P
Version:
Limit value monitoring, Input : Temperature, PT100, Output : 2 x relays, Signal converter/isolator
Type of connection:
Screw connection
Order No.:
7940045760
Type:
ACT20P-UI-2RCO-DC-S
Version:
Limit value monitoring, Input : universal U, I, R,ϑ, Output : 2 x relays, Input: temperature, R, U, I, Relay output, 24 V DC power supply
Type of connection:
PUSH IN
Order No.:
2456840000
Type:
ACT20P-UI-2RCO-DC-P
Version:
Limit value monitoring, Input : universal U, I, R,ϑ, Output : 2 x relays, Input: temperature, R, U, I, Relay output, 24 V DC power supply
Type of connection:
Screw connection
Order No.:
1238910000
Type:
ACT20P-UI-2RCO-AC-S
Version:
Limit value monitoring, Input : universal U, I, R,ϑ, Output : 2 x relays, Input: temperature, R, U, I, Relay output, 90…264 V AC power supply
Type of connection:
PUSH IN
Order No.:
2495690000
Type:
ACT20P-UI-2RCO-AC-P
Version:
Limit value monitoring, Input : universal U, I, R,ϑ, Output : 2 x relays, Input: temperature, R, U, I, Relay output, 90…264 V AC power supply
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.