Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Isolating amplifier and measuring transducer
Power Supplies
Electronics Housings
Lightning and Surge Protection
e-mobility
Photovoltaics
Fieldbus Distributors
SPDs for energy systems
SPDs for instrumentation and control (I&C)
SPDs for data interfaces
Accessories
AC voltage
Photovoltaics
VPU PV I + II
VPU PV II
600 V
1000 V
1500 V
With remote alert
Without remote alert
Spare Arrester
General ordering data
Order No.
3012980000
Type
VPU PV I+II 5 1500
GTIN (EAN)
4099986922587
Qty.
1 pc(s).
Dimensions and weights
Depth
86 mm
Depth (inches)
3.386 inch
Height
96.5 mm
Height (inches)
3.799 inch
Width
90 mm
Width (inches)
3.543 inch
Net weight
760 g
Temperatures
Storage temperature
-40 °C...85 °C
Operating temperature
-40 °C...85 °C
Humidity
5 - 95% rel. humidity
Environmental Product Compliance
RoHS Compliance Status
Compliant without exemption
REACH SVHC
No SVHC above 0.1 wt%
General data
Number of poles
5
Protection degree
IP20 in installed state
Colour
orange, black
Insulation coordination acc. to EN 50178
Pollution severity
2
Surge voltage category
I, III
Photovoltaic technical data
Discharge current In (8/20 µs)
20 kA
Lightning test current Iimp (10/350 µs)
5 kA
Operating height in the grounded PV system
≤ 2000 m
Operating height in ungrounded PV system
≤ 4000 m
PV system voltage, max. Ucpv
1,500 V
Protection level Up (+/- , -/PE , +/PE)
≤ 5,0 kV
Protection level Up (+/-)
≤ 5,0 kV
Short-circuit curent ISCPV
11,000 A
Standards
EN 61643-31, EN 50539-11
Total discharge current Itotal ( 8/20µs)
50 kA
Total discharge current Itotal (10/350µs)
10 kA
Rated data IEC / EN
Discharge current Imax (8/20µs) wire-PE
30 kA
Leakage current at Un
30 µA
Lightning test current Iimp (10/350 µs)
5 kA
Max. continuous voltage, Uc (DC)
1500 V
Number of poles
5
Rated voltage (DC)
1500 V
Response time
≤ 25 ns
SPD type
T2, T1
Short-circuit current rating ISCCR
50 kA
Signalling contact
No
Standards
EN 61643-31, EN 50539-11
Suitable for
Photovoltaics
Voltage type
DC
Connection data
Stripping length
18 mm
Wire connection method
Screw connection
Stripping length, rated connection
18 mm
Tightening torque, min.
3 Nm
Tightening torque, max.
4.5 Nm
Clamping range, rated connection
6 mm²
Clamping range, min.
1.5 mm²
Clamping range, max.
35 mm²
Wire cross-section, solid, min.
1.5 mm²
Wire cross-section, solid, max.
35 mm²
Wire connection cross section, finely stranded, max.
25 mm²
Connection cross-section, stranded, min.
1.5 mm²
Connection cross-section, stranded, max.
35 mm²
Electrical data
Voltage type
DC
Guarantee
Time interval
5 years
Classifications
ETIM 6.0
EC000941
ETIM 7.0
EC000941
ETIM 8.0
EC000941
ETIM 9.0
EC000941
ECLASS 9.0
27-13-08-05
ECLASS 9.1
27-13-08-05
ECLASS 10.0
27-13-08-05
ECLASS 11.0
27-13-08-05
ECLASS 12.0
27-17-90-90
ECLASS 13.0
27-17-90-90
ECLASS 14.0
27-17-90-90
Approvals
Approvals
ROHS
Conform
Type of connection:
Screw connection
Order No.:
2530580000
Type:
VPU PV I+II 3 1500
Version:
Surge voltage arrester, Low voltage, Surge protection I / II
Type of connection:
Screw connection
Order No.:
2795570000
Type:
VPU PV I+II 3 1500 E
Version:
Surge voltage arrester, Low voltage, Surge protection I / II
Order No.
3012980000
Type
VPU PV I+II 5 1500
GTIN (EAN)
4099986922587
Qty.
1 pc(s).
Depth
86 mm
Depth (inches)
3.386 inch
Height
96.5 mm
Height (inches)
3.799 inch
Width
90 mm
Width (inches)
3.543 inch
Net weight
760 g
Storage temperature
-40 °C...85 °C
Operating temperature
-40 °C...85 °C
Humidity
5 - 95% rel. humidity
RoHS Compliance Status
Compliant without exemption
REACH SVHC
No SVHC above 0.1 wt%
Number of poles
5
Protection degree
IP20 in installed state
Colour
orange, black
Pollution severity
2
Surge voltage category
I, III
Discharge current In (8/20 µs)
20 kA
Lightning test current Iimp (10/350 µs)
5 kA
Operating height in the grounded PV system
≤ 2000 m
Operating height in ungrounded PV system
≤ 4000 m
PV system voltage, max. Ucpv
1,500 V
Protection level Up (+/- , -/PE , +/PE)
≤ 5,0 kV
Protection level Up (+/-)
≤ 5,0 kV
Short-circuit curent ISCPV
11,000 A
Standards
EN 61643-31, EN 50539-11
Total discharge current Itotal ( 8/20µs)
50 kA
Total discharge current Itotal (10/350µs)
10 kA
Discharge current Imax (8/20µs) wire-PE
30 kA
Leakage current at Un
30 µA
Lightning test current Iimp (10/350 µs)
5 kA
Max. continuous voltage, Uc (DC)
1500 V
Number of poles
5
Rated voltage (DC)
1500 V
Response time
≤ 25 ns
SPD type
T2, T1
Short-circuit current rating ISCCR
50 kA
Signalling contact
No
Standards
EN 61643-31, EN 50539-11
Suitable for
Photovoltaics
Voltage type
DC
Stripping length
18 mm
Wire connection method
Screw connection
Stripping length, rated connection
18 mm
Tightening torque, min.
3 Nm
Tightening torque, max.
4.5 Nm
Clamping range, rated connection
6 mm²
Clamping range, min.
1.5 mm²
Clamping range, max.
35 mm²
Wire cross-section, solid, min.
1.5 mm²
Wire cross-section, solid, max.
35 mm²
Wire connection cross section, finely stranded, max.
25 mm²
Connection cross-section, stranded, min.
1.5 mm²
Connection cross-section, stranded, max.
35 mm²
ETIM 6.0
EC000941
ETIM 7.0
EC000941
ETIM 8.0
EC000941
ETIM 9.0
EC000941
ECLASS 9.0
27-13-08-05
ECLASS 9.1
27-13-08-05
ECLASS 10.0
27-13-08-05
ECLASS 11.0
27-13-08-05
ECLASS 12.0
27-17-90-90
ECLASS 13.0
27-17-90-90
ECLASS 14.0
27-17-90-90
Approvals
ROHS
Conform
Type of connection:
Screw connection
Order No.:
2530580000
Type:
VPU PV I+II 3 1500
Version:
Surge voltage arrester, Low voltage, Surge protection I / II
Type of connection:
Screw connection
Order No.:
2795570000
Type:
VPU PV I+II 3 1500 E
Version:
Surge voltage arrester, Low voltage, Surge protection I / II
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.