Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Analogue Signal Conditioning
Power Supplies
Electronics Housings
Lightning and Surge Protection
Photovoltaics
e-mobility
Fieldbus Distributors
SPDs for energy systems
SPDs for instrumentation and control (I&C)
SPDs for data interfaces
Accessories
AC voltage
Photovoltaics
DIN rail TS 35
40mm busbars
Type I
Type II
Type III
VPU Type I Series
VPU Type II Series
VPU AC II
VPU AC II+III S
VPU AC II US series
VPU AC II F with integrated fuse
230/400V IoT
General ordering data
Version
Surge voltage arrester, Low voltage, Surge protection, TN-S, TN-C-S, TT, UP (L/N-PE) ≤ 1.5 kV
Order No.
2735900000
Type
VPU IOT AC II 3+1 300/50
GTIN (EAN)
4064675257585
Qty.
1 pc(s).
Dimensions and weights
Depth
68 mm
Depth (inches)
2.677 inch
Depth including DIN rail
76 mm
Height
90 mm
Height (inches)
3.543 inch
Width
108 mm
Width (inches)
4.252 inch
Net weight
600 g
Temperatures
Storage temperature
-40 °C...85 °C
Operating temperature
-40 °C...85 °C
Humidity
5 - 95% rel. humidity
Environmental Product Compliance
REACH SVHC
/
RoHS Compliance Status
Compliant without exemption
General data
Colour
black, orange
Design
Installation housing; 6 TE, Insta IP 20
Operating altitude
≤ 4000 m
Optical function display
green = OK; red = arrester is defective - replace
Protection degree
IP20 in installed state
Rail
TS 35
Segment
Power distribution
UL 94 flammability rating
V-0
Version
Surge protection
auxiliary contact
No
Insulation coordination acc. to EN 50178
Pollution severity
2
Surge voltage category
III
Rated data IEC / EN
Discharge current Imax (8/20µs) N-PE
65 kA
Discharge current Imax (8/20µs) wire-PE
50 kA
Discharge current In (8/20µs) N-PE
40 kA
Discharge current In (8/20µs) wire-PE
20 kA
Energy coordination (≤10 m)
Type II, Type III
Follow-on current extinguishing capability Ifi
Follow current need not be taken into account
Frequency range, max.
60 Hz
Frequency range, min.
50 Hz
Fuse
No Fuse neccessary ≤315 A gG, 250 A gG @50 kA Isccr, 315 A gG @25 kA Isccr
Leakage current at Un
1 µA
Low voltage network
TN-S, TN-C-S, TT
Mains voltage
230 V / 400 V
Max. continuous voltage, Uc (AC)
300 V
Max. continuous voltage, Uc (N-PE)
305 V
Number of poles
6
Protection level UP (typ.)
≤ 1.5 kV
Protection level Up at IN (N-PE)
≤ 1.5 kV
Rated voltage (AC)
230 V
Requirements category acc. to IEC 61643-11
Type II
Requirements class, acc. to EN 61643-11
T2
Response time
≤ 25 ns
SPD type
T2
Short-circuit current rating ISCCR
50 kA
Signalling contact
No
Standards
IEC 61643-11, EN 61643-11
Temporary surge voltage (over-voltage) - TOV
337 V
Voltage type
AC
Connection data
Stripping length
18 mm
Wire connection method
Screw connection
Type of connection
Screw connection
Stripping length, rated connection
18 mm
Tightening torque, min.
2 Nm
Tightening torque, max.
3 Nm
Clamping range, rated connection
16 mm²
Clamping range, min.
4 mm²
Clamping range, max.
35 mm²
Wire cross-section, solid, min.
2.5 mm²
Wire cross-section, solid, max.
35 mm²
Wire connection cross section, finely stranded, min.
35 mm²
Wire connection cross section, finely stranded, max.
4 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.
2.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.
25 mm²
Connection cross-section, stranded, min.
2.5 mm²
Connection cross-section, stranded, max.
25 mm²
Guarantee
Time interval
5 years
Important note
Product information
For use in DC applications, please use the fuse of SIBA Type NH2XL aR/aSF DC 1500 V
Classifications
ETIM 6.0
EC000941
ETIM 7.0
EC000941
ETIM 8.0
EC000941
ETIM 9.0
EC000941
ECLASS 9.0
27-13-08-05
ECLASS 9.1
27-13-08-05
ECLASS 10.0
27-13-08-05
ECLASS 11.0
27-13-08-05
ECLASS 12.0
27-17-90-90
ECLASS 13.0
27-17-90-90
ECLASS 14.0
27-17-90-90
Approvals
Approvals
ROHS
Conform
Order No.:
2810460000
Type of connection:
Plug-in connection
Type:
VPU AC IOT II 0 300/50
Version:
Spare arrester, Surge protection, Single-phase
Version
Surge voltage arrester, Low voltage, Surge protection, TN-S, TN-C-S, TT, UP (L/N-PE) ≤ 1.5 kV
Order No.
2735900000
Type
VPU IOT AC II 3+1 300/50
GTIN (EAN)
4064675257585
Qty.
1 pc(s).
Depth
68 mm
Depth (inches)
2.677 inch
Depth including DIN rail
76 mm
Height
90 mm
Height (inches)
3.543 inch
Width
108 mm
Width (inches)
4.252 inch
Net weight
600 g
Storage temperature
-40 °C...85 °C
Operating temperature
-40 °C...85 °C
Humidity
5 - 95% rel. humidity
REACH SVHC
/
RoHS Compliance Status
Compliant without exemption
Colour
black, orange
Design
Installation housing; 6 TE, Insta IP 20
Operating altitude
≤ 4000 m
Optical function display
green = OK; red = arrester is defective - replace
Protection degree
IP20 in installed state
Rail
TS 35
Segment
Power distribution
UL 94 flammability rating
V-0
Version
Surge protection
auxiliary contact
No
Pollution severity
2
Surge voltage category
III
Discharge current Imax (8/20µs) N-PE
65 kA
Discharge current Imax (8/20µs) wire-PE
50 kA
Discharge current In (8/20µs) N-PE
40 kA
Discharge current In (8/20µs) wire-PE
20 kA
Energy coordination (≤10 m)
Type II, Type III
Follow-on current extinguishing capability Ifi
Follow current need not be taken into account
Frequency range, max.
60 Hz
Frequency range, min.
50 Hz
Fuse
No Fuse neccessary ≤315 A gG, 250 A gG @50 kA Isccr, 315 A gG @25 kA Isccr
Leakage current at Un
1 µA
Low voltage network
TN-S, TN-C-S, TT
Mains voltage
230 V / 400 V
Max. continuous voltage, Uc (AC)
300 V
Max. continuous voltage, Uc (N-PE)
305 V
Number of poles
6
Protection level UP (typ.)
≤ 1.5 kV
Protection level Up at IN (N-PE)
≤ 1.5 kV
Rated voltage (AC)
230 V
Requirements category acc. to IEC 61643-11
Type II
Requirements class, acc. to EN 61643-11
T2
Response time
≤ 25 ns
SPD type
T2
Short-circuit current rating ISCCR
50 kA
Signalling contact
No
Standards
IEC 61643-11, EN 61643-11
Temporary surge voltage (over-voltage) - TOV
337 V
Voltage type
AC
Stripping length
18 mm
Wire connection method
Screw connection
Type of connection
Screw connection
Stripping length, rated connection
18 mm
Tightening torque, min.
2 Nm
Tightening torque, max.
3 Nm
Clamping range, rated connection
16 mm²
Clamping range, min.
4 mm²
Clamping range, max.
35 mm²
Wire cross-section, solid, min.
2.5 mm²
Wire cross-section, solid, max.
35 mm²
Wire connection cross section, finely stranded, min.
35 mm²
Wire connection cross section, finely stranded, max.
4 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.
2.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.
25 mm²
Connection cross-section, stranded, min.
2.5 mm²
Connection cross-section, stranded, max.
25 mm²
Product information
For use in DC applications, please use the fuse of SIBA Type NH2XL aR/aSF DC 1500 V
ETIM 6.0
EC000941
ETIM 7.0
EC000941
ETIM 8.0
EC000941
ETIM 9.0
EC000941
ECLASS 9.0
27-13-08-05
ECLASS 9.1
27-13-08-05
ECLASS 10.0
27-13-08-05
ECLASS 11.0
27-13-08-05
ECLASS 12.0
27-17-90-90
ECLASS 13.0
27-17-90-90
ECLASS 14.0
27-17-90-90
Approvals
ROHS
Conform
Order No.:
2810460000
Type of connection:
Plug-in connection
Type:
VPU AC IOT II 0 300/50
Version:
Spare arrester, Surge protection, Single-phase
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.