Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Analogue Signal Conditioning
Power Supplies
Electronics Housings
Lightning and Surge Protection
e-mobility
Photovoltaics
Fieldbus Distributors
Switched-mode power supply units
Electronic load monitoring
Communication modules
Uninterruptible power supply
DC/DC converter
Diode- and redundancy modules
Pre charge unit
Decentralised switched-mode power supply units IP65
Decentralised electronic load monitoring IP65
Accessories
maxGUARD
topGUARD
General ordering data
Version
Electronic load monitoring
Order No.
2624980000
Type
TGD ELM-6
GTIN (EAN)
4050118689426
Qty.
1 pc(s).
Dimensions and weights
Depth
96.5 mm
Depth (inches)
3.799 inch
Height
125 mm
Height (inches)
4.921 inch
Width
6.1 mm
Width (inches)
0.24 inch
Net weight
44 g
Temperatures
Storage temperature
-40 °C...85 °C
Operating temperature
-25 °C...70 °C
Environmental Product Compliance
REACH SVHC
Lead 7439-92-1
SCIP
925510b1-0d14-47d7-86d9-90447b22ecd3
Input
DC input voltage range
18…30 V DC
Input fuse (internal)
Yes
Rated input voltage
24 V DC
max. admissible residual ripple at the input
100 mVpp
Output
Adjustable rated current
Yes
Capacitive load
15,000 µF
Connection system
PUSH IN
Rated current
6 A
Rated current (per channel)
6 A
Triggering characteristic
see characteristic curve
General data
Conformal coating
No
Function key
Activation time < 3s, Reset, ON
MTTF
According to Standard
SN 29500
Operating time (hours), min.
2,505,000 h
Ambient temperature
40 °C
Input voltage
24 V
Output power
144 W
Duty cycle
100 %
Protection degree
IP20
Relay to activate the output
No
Surge voltage category
III
Insulation coordination
Surge voltage category
III
Connection data (output)
Conductor cross-section, AWG/kcmil , max.
12
Conductor cross-section, AWG/kcmil , min.
26
Conductor cross-section, flexible , max.
2.5 mm²
Conductor cross-section, flexible , min.
0.14 mm²
Conductor cross-section, rigid , max.
2.5 mm²
Conductor cross-section, rigid , min.
0.14 mm²
Connection system
PUSH IN
Number of terminals
2 (+ / -)
Screwdriver blade
0.6 x 3.5
Signalling
LED green
Operation (failure-free), Early warning: I Out > 90% I Rated (flashing)
Red LED
Load monitoring has disconnected, Load monitoring has triggered (flashing), Internal error (rapid flashing)
Yellow LED
Address is assigned, Address is being assigned (flashing)
Approbations
Certificate no. (cULus)
E258476
Institute (cULus)
CULUS
Classifications
ETIM 6.0
EC002057
ETIM 7.0
EC002057
ETIM 8.0
EC002057
ETIM 9.0
EC001437
ECLASS 9.0
27-37-10-16
ECLASS 9.1
27-37-10-16
ECLASS 10.0
27-37-10-16
ECLASS 11.0
27-37-10-16
ECLASS 12.0
27-37-10-16
ECLASS 13.0
27-37-10-16
Approvals
Approvals
UL File Number Search
UL Website
Certificate no. (cULus)
E258476
Order No.:
2624990000
Type:
TGD ELM-12
Version:
Electronic load monitoring
Order No.:
2656670000
Type:
TGD ELM-4 CL2
Version:
Electronic load monitoring
Order No.:
2625000000
Type:
TGD FIM-C
Version
Electronic load monitoring
Order No.
2624980000
Type
TGD ELM-6
GTIN (EAN)
4050118689426
Qty.
1 pc(s).
Depth
96.5 mm
Depth (inches)
3.799 inch
Height
125 mm
Height (inches)
4.921 inch
Width
6.1 mm
Width (inches)
0.24 inch
Net weight
44 g
Storage temperature
-40 °C...85 °C
Operating temperature
-25 °C...70 °C
REACH SVHC
Lead 7439-92-1
SCIP
925510b1-0d14-47d7-86d9-90447b22ecd3
DC input voltage range
18…30 V DC
Input fuse (internal)
Yes
Rated input voltage
24 V DC
max. admissible residual ripple at the input
100 mVpp
Adjustable rated current
Yes
Capacitive load
15,000 µF
Connection system
PUSH IN
Rated current
6 A
Rated current (per channel)
6 A
Triggering characteristic
see characteristic curve
Conformal coating
No
Function key
Activation time < 3s, Reset, ON
MTTF
According to Standard
SN 29500
Operating time (hours), min.
2,505,000 h
Ambient temperature
40 °C
Input voltage
24 V
Output power
144 W
Duty cycle
100 %
Protection degree
IP20
Relay to activate the output
No
Surge voltage category
III
Surge voltage category
III
Conductor cross-section, AWG/kcmil , max.
12
Conductor cross-section, AWG/kcmil , min.
26
Conductor cross-section, flexible , max.
2.5 mm²
Conductor cross-section, flexible , min.
0.14 mm²
Conductor cross-section, rigid , max.
2.5 mm²
Conductor cross-section, rigid , min.
0.14 mm²
Connection system
PUSH IN
Number of terminals
2 (+ / -)
Screwdriver blade
0.6 x 3.5
LED green
Operation (failure-free), Early warning: I Out > 90% I Rated (flashing)
Red LED
Load monitoring has disconnected, Load monitoring has triggered (flashing), Internal error (rapid flashing)
Yellow LED
Address is assigned, Address is being assigned (flashing)
Certificate no. (cULus)
E258476
Institute (cULus)
CULUS
ETIM 6.0
EC002057
ETIM 7.0
EC002057
ETIM 8.0
EC002057
ETIM 9.0
EC001437
ECLASS 9.0
27-37-10-16
ECLASS 9.1
27-37-10-16
ECLASS 10.0
27-37-10-16
ECLASS 11.0
27-37-10-16
ECLASS 12.0
27-37-10-16
ECLASS 13.0
27-37-10-16
Approvals
UL File Number Search
UL Website
Certificate no. (cULus)
E258476
Order No.:
2624990000
Type:
TGD ELM-12
Version:
Electronic load monitoring
Order No.:
2656670000
Type:
TGD ELM-4 CL2
Version:
Electronic load monitoring
Order No.:
2625000000
Type:
TGD FIM-C
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.