ITS 24-240VUC 1CO M7C
         

Icon
Icon
Icon
Icon
Icon
Icon
Icon
 

General ordering data

Version IT TIMER, Multifunction timing relay, with separate control input, Number of contacts: 1, CO contact, AgNi, Rated control voltage: 24...48 V DC, 24...230 V AC, Continuous current: 5 A, Screw connection
Order No. 2496190000
Type ITS 24-240VUC 1CO M7C
GTIN (EAN) 4050118506211
Qty. 1 pc(s).

Dimensions and weights

Depth 57.9 mm
Depth (inches) 2.28 inch
Height 98 mm
Height (inches) 3.858 inch
Width 17.5 mm
Width (inches) 0.689 inch
Net weight 57 g

Temperatures

Storage temperature -40 °C...70 °C
Operating temperature -25 °C...50 °C
Humidity 25 - 75%, no condensation

Control side

Rated control voltage 24...48 V DC, 24...230 V AC
Power rating 8 VA @ 230 V AC, 0.4 W at 24 V DC
Status indicator LED green (U/t): flashes when time runs, lights permanently with supply voltage applied, LED yellow (R): relay closed
Time ranges 0.05 s - 1 s, 0.5 s - 10 s, 3 s - 60 s, 0.5 min - 10 min, 3 min - 1 h, 0.5 h - 10 h
Setting tolerance 5 %
Max. reset time after voltage interruption 100 ms
Basic accuracy ±6% (of scale-end value, for time range 0.05 s - 1 s), ±1.5% (of scale-end value, for all other time ranges)
Min. pulse duration 50 ms
Repeat accuracy <0.5 % or ±5 ms

Load side

Rated switching voltage 250 V AC
Continuous current 5 A
Max. switching voltage, AC 250 V
Max. switching voltage, DC 30 V
AC switching capacity (resistive), max. 1250 VA
DC switching capacity (resistive), max. 90 W
Contact type 1 CO contact (AgNi)
Mechanical service life 1 x 106 switching cycles
Min. switching power 10 mA @ 12 V, 100 mA @ 5 V

General data

Design Installation housing; 1TE
Suitable for front mounting No
Version with separate control input
Rail TS 35
Test button available No
Mechanical switch position indicator No
Resistance to vibration EN 61812-1 10 Hz...60 Hz: 0.15 mm, 60 Hz...150 Hz: 2 g

Insulation coordination

Rated voltage 300 V
Pollution severity 2
Surge voltage category II
Clearance and creepage distances for control side - load side ≥ 3 mm
Dielectric strength for control side - load side 1.6 kV
Impulse withstand voltage 2.5 kV
Protection degree IP20

Connection data

Wire connection method Screw connection
Stripping length, rated connection 7 mm
Tightening torque, max. 0.5 Nm
Clamping range, rated connection 2.5 mm²
Clamping range, min. 0.25 mm²
Clamping range, max. 2.5 mm²
Wire connection cross section AWG, min. AWG 23
Wire connection cross section AWG, max. AWG 14
Wire cross-section, solid, min. 0.25 mm²
Wire cross-section, solid, max. 2.5 mm²
Wire connection cross section, finely stranded, min. 0.25 mm²
Wire connection cross section, finely stranded, max. 2.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min. 0.25 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max. 2.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min. 0.25 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max. 2.5 mm²
Blade size size PH1

Downloads

Classifications

ETIM 6.0 EC001439
ETIM 7.0 EC001439
ETIM 8.0 EC001439
ETIM 9.0 EC001439
ECLASS 9.0 27-37-16-05
ECLASS 9.1 27-37-16-05
ECLASS 10.0 27-37-16-05
ECLASS 11.0 27-37-16-05
ECLASS 12.0 27-37-16-05
ECLASS 13.0 27-37-16-05

Approvals

Approvals CE UKCA
ROHS Conform

Related products

Order No.: 2545120000
Type: ITS 24-240VUC M7C PU10
Version:
IT TIMER, Multifunction timing relay, with separate control input, Number of contacts: 1, CO contact, AgNi, Rated control voltage: 24...48 V DC, 24...230 V AC, Continuous current: 5 A, Screw connection
 
Contact
Weidmüller Interface GmbH & Co. KG
 
+49 5231 14-0
+49 5231 14-292083
More information
Decentralised automation solutions
Energy Management Solutions
Industrial Analytics
Industrial IoT Solutions
More information
Mobility Concepts
Photovoltaics
Wind Solutions
Workplace Solutions
More information
Single Pair Ethernet
Weidmüller Configurator
Support & Service
Contact
Disposal Instructions
Engineering data
Repairs and replacement parts