AAP22 4 LI-FS 30-70V
         

Icon
Icon
Icon
 

General ordering data

Version Distribution terminal with fuse, PUSH IN, 4 mm², 70 V, 6.3 A, dark beige
Order No. 2460140000
Type AAP22 4 LI-FS 30-70V
GTIN (EAN) 4050118475562
Qty. 50 pc(s).

Dimensions and weights

Depth 82 mm
Depth (inches) 3.228 inch
Depth including DIN rail 82.5 mm
Height 129 mm
Height (inches) 5.079 inch
Width 6.1 mm
Width (inches) 0.24 inch
Net weight 25.7 g

Temperatures

Storage temperature -25 °C...55 °C
Continuous operating temp., min. -60 °C
Continuous operating temp., max. 130 °C

Material data

Material Wemid
Colour dark beige
Colour of operational elements red, blue
UL 94 flammability rating V-0

Rating data IECEx/ATEX

Certificate No. (ATEX) TUEV17ATEX8064U
Certificate No. (IECEX) IECEXTUR17.0030U
Current (ATEX) 6.3 A
Wire cross section max. (ATEX) 4 mm²
Current (IECEX) 6.3 A
Wire cross section max. (IECEX) 4 mm²
Marking EN 60079-7 Ex ec II C Gc
Ex 2014/34/EU label II 2 G D

System specifications

Version with LED
End cover plate required Yes
Number of potentials
Rail TS 35

Additional technical data

Installation advice Rail
Open sides right
Snap-on No
Type of fixing Snap-on
Type of mounting TS 35
With snap-in pegs No

CSA rating data

Certificate No. (CSA) 200039-70089609
Current size B (CSA) 10 A
Current size D (CSA) 10 A
Voltage size B (CSA) 300 V
Voltage size D (CSA) 300 V
Wire cross section max. (CSA) 10 AWG
Wire cross section min. (CSA) 26 AWG

Conductors for clamping (rated connection)

Blade size 0.6 x 3.5 mm
Clamping range, max. 4 mm²
Clamping range, min. 0.14 mm²
Connection cross-section, stranded, max. 4 mm²
Connection cross-section, stranded, min. 0.5 mm²
Connection direction top
Gauge to IEC 60947-1 A4
Number of connections
Stripping length 12 mm
Tube length for twin wire-end ferrule
Cross-section for conductor connection
min. 0.5 mm²
max. 1.5 mm²
Tube length
min. 8 mm
max. 12 mm
Tube length for wire-end ferrule with plastic collar DIN 46228/4
Tube length
min. 6 mm
max. 12 mm
Cross-section for conductor connection
min. 0.5 mm²
max. 1 mm²
Tube length
min. 8 mm
max. 12 mm
Cross-section for conductor connection
min. 1.5 mm²
max. 2.5 mm²
Tube length
min. 10 mm
max. 12 mm
Cross-section for conductor connection
nominal 4 mm²
Tube length for wire-end ferrule without plastic collar DIN 46228/1
Cross-section for conductor connection
min. 0.5 mm²
max. 1 mm²
Tube length
min. 6 mm
max. 10 mm
Cross-section for conductor connection
min. 1.5 mm²
max. 2.5 mm²
Tube length
min. 7 mm
max. 12 mm
Cross-section for conductor connection
nominal 4 mm²
Tube length
min. 9 mm
max. 15 mm
Twin wire-end ferrules, max. 1.5 mm²
Twin wire-end ferrules, min. 0.5 mm²
Type of connection PUSH IN
Wire connection cross section AWG, max. AWG 12
Wire connection cross section AWG, min. AWG 26
Wire connection cross section, finely stranded, max. 4 mm²
Wire connection cross section, finely stranded, min. 0.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, max. 4 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, min. 0.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max. 4 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min. 0.5 mm²
Wire connection cross-section, solid core, max. 4 mm²
Wire connection cross-section, solid core, min. 0.5 mm²

General

Installation advice Rail
Rail TS 35
Standards In accordance with IEC 60947-7-1, In accordance with IEC 60947-7-3
Wire connection cross section AWG, max. AWG 12
Wire connection cross section AWG, min. AWG 26

Rating data

Rated cross-section 4 mm²
Rated voltage 70 V
Rated voltage to adjoining terminal 500 V
Rated DC voltage 70 V
Rated current 6.3 A
Current at maximum wires 6.3 A
Standards In accordance with IEC 60947-7-1, In accordance with IEC 60947-7-3
Volume resistance according to IEC 60947-7-x 1 mΩ
Rated impulse withstand voltage 4 kV
Power loss in accordance with IEC 60947-7-x 1.02 W
Pollution severity 2
Surge voltage category III

UL rating data

Certificate No. (cURus) E60693
Conductor size Factory wiring max. (cURus) 10 AWG
Conductor size Factory wiring min. (cURus) 26 AWG
Conductor size Field wiring max. (cURus) 10 AWG
Conductor size Field wiring min. (cURus) 26 AWG
Current size B (cURus) 10 A
Current size D (cURus) 10 A
Voltage size B (cURus) 300 V
Voltage size D (cURus) 300 V

Important note

Product information The voltage depends on the selected fuse element or the selected indicator light

Downloads

Classifications

ETIM 6.0 EC000899
ETIM 7.0 EC000899
ETIM 8.0 EC000899
ETIM 9.0 EC000899
ECLASS 9.0 27-14-11-16
ECLASS 9.1 27-14-11-16
ECLASS 10.0 27-14-11-16
ECLASS 11.0 27-14-11-16
ECLASS 12.0 27-14-11-16
ECLASS 13.0 27-25-01-13

Approvals

Approvals CCCEX CE CSA CURUS DETNORVER IECEXTUR TUEVNATEX UKCA
ROHS Conform
UL File Number Search UL Website
Certificate No. (cURus) E60693

Related products

Order No.: 2429000000
Type: AAP22 10 FE-LO
Version:
Supply terminal, PUSH IN, 10 mm², 250 V, 57 A, dark beige
 
Order No.: 2428990000
Type: AAP22 10 LO-LO
Version:
Supply terminal, PUSH IN, 10 mm², 250 V, 57 A, dark beige
 
Order No.: 2429010000
Type: AAP22 4 LI-FS
Version:
Distribution terminal with fuse, PUSH IN, 4 mm², 500 V, 6.3 A, dark beige
 
Order No.: 2459010000
Type: AAP22 4 LI-FS 10-36V
Version:
Distribution terminal with fuse, PUSH IN, 4 mm², 36 V, 6.3 A, dark beige
 
Order No.: 2460120000
Type: AAP22 4 LI-FS 100-250V
Version:
Distribution terminal with fuse, PUSH IN, 4 mm², 250 V, 6.3 A, dark beige
 
Order No.: 2460130000
Type: AAP22 4 LI-FS 60-150V
Version:
Distribution terminal with fuse, PUSH IN, 4 mm², 150 V, 6.3 A, dark beige
 
Contact
Weidmüller Interface GmbH & Co. KG
 
+49 5231 14-0
+49 5231 14-292083
More information
Decentralised automation solutions
Energy Management Solutions
Industrial Analytics
Industrial IoT Solutions
More information
Mobility Concepts
Photovoltaics
Wind Solutions
Workplace Solutions
More information
Single Pair Ethernet
Weidmüller Configurator
Support & Service
Contact
Disposal Instructions
Engineering data
Repairs and replacement parts