Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Terminal Blocks
Connectors
PCB Terminals and Connectors
Enclosure Systems and Components
Contactless Connectivity
Cable Entry Systems and Components
Cord sets, Patchcords and Cables
PLC Interfaces and Migration Solutions
Service Interfaces
Distribution Boxes
Universal range
Application range
Terminal blocks for the direct lettering
Accessories
Power feed-in
Power distribution
Instrument transformer wiring
Control voltage distribution
Signal wiring
Signal marshalling
Shielding and earthing
Building installation wiring
TTB range
Tension clamp technology
Clamping yoke technology
Stud technology
Accessories
Measuring transducer terminal blocks
6 mm²
General ordering data
Version
Test-disconnect terminal, Tension-clamp connection, 6 mm², 400 V, 41 A, sliding, dark beige
Order No.
1771950000
Type
ZTL 6/STB
GTIN (EAN)
4032248127290
Qty.
20 pc(s).
Dimensions and weights
Depth
46.5 mm
Depth (inches)
1.831 inch
Depth including DIN rail
48 mm
Height
106 mm
Height (inches)
4.173 inch
Width
8 mm
Width (inches)
0.315 inch
Net weight
34.864 g
Temperatures
Storage temperature
-25 °C...55 °C
Continuous operating temp., min.
-50 °C
Continuous operating temp., max.
120 °C
Environmental Product Compliance
REACH SVHC
Lead 7439-92-1
SCIP
a4720f28-c1be-43c4-a115-55415c294bda
RoHS Compliance Status
Compliant with exemption
RoHS Exemption (if applicable/known)
6c
Material data
Material
Wemid
Colour
dark beige
UL 94 flammability rating
V-0
System specifications
Version
Tension-clamp connection, Spacer, With sockets, for plug-in cross-connector, One end without connector
End cover plate required
Yes
Number of potentials
1
Number of levels
1
Number of clamping points per level
2
Number of potentials per tier
1
Levels cross-connected internally
No
PE connection
No
Rail
TS 35, TS 32
N-function
No
PE function
No
PEN function
No
Additional technical data
Explosion-tested version
No
Installation advice
Direct mounting
Open sides
right
Type of mounting
Snap-on
CSA rating data
Certificate No. (CSA)
200039-1152892
Current size B (CSA)
33 A
Current size C (CSA)
33 A
Voltage size B (CSA)
300 V
Voltage size C (CSA)
300 V
Wire cross section max. (CSA)
8 AWG
Wire cross section min. (CSA)
20 AWG
Conductors for clamping (additional connection)
Conductor cross-section, flexible plus plastic collar DIN 46228/1, further connection, max.
6 mm²
Conductors for clamping (rated connection)
Blade size
0.8 x 4.0 mm
Clamping range, max.
10 mm²
Clamping range, min.
0.5 mm²
Connection cross-section, stranded, max.
6 mm²
Connection cross-section, stranded, min.
1.5 mm²
Connection direction
top
Gauge to IEC 60947-1
A5
Number of connections
2
Stripping length
13 mm
Tightening torque, max.
0.6 Nm
Tightening torque, min.
0.5 Nm
Type of connection
Tension-clamp connection
Wire connection cross section, finely stranded, max.
6 mm²
Wire connection cross section, finely stranded, min.
0.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, max.
6 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, min.
0.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.
6 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.
0.5 mm²
Wire connection cross-section, solid core, max.
10 mm²
Wire connection cross-section, solid core, min.
0.5 mm²
Dimensions
TS 32 offset
54.5 mm
General
Installation advice
Direct mounting
Rail
TS 35, TS 32
Standards
IEC 60947-7-1
Rating data
Rated cross-section
6 mm²
Rated voltage
400 V
Rated DC voltage
400 V
Rated current
41 A
Current at maximum wires
52 A
Standards
IEC 60947-7-1
Volume resistance according to IEC 60947-7-x
0.78 mΩ
Rated impulse withstand voltage
8 kV
Power loss in accordance with IEC 60947-7-x
1.31 W
Pollution severity
3
UL rating data
Certificate No. (UR)
E60693
Conductor size Factory wiring max. (UR)
8 AWG
Conductor size Factory wiring min. (UR)
20 AWG
Conductor size Field wiring max. (UR)
8 AWG
Conductor size Field wiring min. (UR)
20 AWG
Current size C (UR)
33 A
Voltage size C (UR)
300 V
Classifications
ETIM 7.0
EC000902
ETIM 8.0
EC000902
ETIM 9.0
EC000902
ECLASS 11.0
27-14-11-26
ECLASS 12.0
27-14-11-26
ECLASS 13.0
27-25-01-09
ECLASS 14.0
27-25-01-09
Version
Test-disconnect terminal, Tension-clamp connection, 6 mm², 400 V, 41 A, sliding, dark beige
Order No.
1771950000
Type
ZTL 6/STB
GTIN (EAN)
4032248127290
Qty.
20 pc(s).
Depth
46.5 mm
Depth (inches)
1.831 inch
Depth including DIN rail
48 mm
Height
106 mm
Height (inches)
4.173 inch
Width
8 mm
Width (inches)
0.315 inch
Net weight
34.864 g
Storage temperature
-25 °C...55 °C
Continuous operating temp., min.
-50 °C
Continuous operating temp., max.
120 °C
REACH SVHC
Lead 7439-92-1
SCIP
a4720f28-c1be-43c4-a115-55415c294bda
RoHS Compliance Status
Compliant with exemption
RoHS Exemption (if applicable/known)
6c
Material
Wemid
Colour
dark beige
UL 94 flammability rating
V-0
Version
Tension-clamp connection, Spacer, With sockets, for plug-in cross-connector, One end without connector
End cover plate required
Yes
Number of potentials
1
Number of levels
1
Number of clamping points per level
2
Number of potentials per tier
1
Levels cross-connected internally
No
PE connection
No
Rail
TS 35, TS 32
N-function
No
PE function
No
PEN function
No
Explosion-tested version
No
Installation advice
Direct mounting
Open sides
right
Type of mounting
Snap-on
Certificate No. (CSA)
200039-1152892
Current size B (CSA)
33 A
Current size C (CSA)
33 A
Voltage size B (CSA)
300 V
Voltage size C (CSA)
300 V
Wire cross section max. (CSA)
8 AWG
Wire cross section min. (CSA)
20 AWG
Conductor cross-section, flexible plus plastic collar DIN 46228/1, further connection, max.
6 mm²
Blade size
0.8 x 4.0 mm
Clamping range, max.
10 mm²
Clamping range, min.
0.5 mm²
Connection cross-section, stranded, max.
6 mm²
Connection cross-section, stranded, min.
1.5 mm²
Connection direction
top
Gauge to IEC 60947-1
A5
Number of connections
2
Stripping length
13 mm
Tightening torque, max.
0.6 Nm
Tightening torque, min.
0.5 Nm
Type of connection
Tension-clamp connection
Wire connection cross section, finely stranded, max.
6 mm²
Wire connection cross section, finely stranded, min.
0.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, max.
6 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, min.
0.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.
6 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.
0.5 mm²
Wire connection cross-section, solid core, max.
10 mm²
Wire connection cross-section, solid core, min.
0.5 mm²
Installation advice
Direct mounting
Rail
TS 35, TS 32
Standards
IEC 60947-7-1
Rated cross-section
6 mm²
Rated voltage
400 V
Rated DC voltage
400 V
Rated current
41 A
Current at maximum wires
52 A
Standards
IEC 60947-7-1
Volume resistance according to IEC 60947-7-x
0.78 mΩ
Rated impulse withstand voltage
8 kV
Power loss in accordance with IEC 60947-7-x
1.31 W
Pollution severity
3
Certificate No. (UR)
E60693
Conductor size Factory wiring max. (UR)
8 AWG
Conductor size Factory wiring min. (UR)
20 AWG
Conductor size Field wiring max. (UR)
8 AWG
Conductor size Field wiring min. (UR)
20 AWG
Current size C (UR)
33 A
Voltage size C (UR)
300 V
ETIM 7.0
EC000902
ETIM 8.0
EC000902
ETIM 9.0
EC000902
ECLASS 11.0
27-14-11-26
ECLASS 12.0
27-14-11-26
ECLASS 13.0
27-25-01-09
ECLASS 14.0
27-25-01-09
Approvals
ROHS
Conform
UL File Number Search
UL Website
Certificate No. (UR)
E60693
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.