Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Analogue Signal Conditioning
Power Supplies
Electronics Housings
Lightning and Surge Protection
e-mobility
Photovoltaics
Fieldbus Distributors
Network-compatible current measuring transducers ACT20C
intrinsically safe signal converter - ACT20X
signal converter and process monitoring - ACT20P
Space-saving signal converter - ACT20M
Signal converter in terminal block format - MCZ
Compact standard signal isolators - PicoPak
Signal - & serial interface converter– WAVESERIES
Process monitoring displays
Analogue-digital / digital-analogue converter
Configuration software
Accessories
Signal converters
Passive isolator
Signal splitter
Temperature transducer
Measuring and monitoring relay
Current measuring transducer
Bridge measuring transducer
Frequency converters
Universal
General ordering data
Version
Signal converter/insulator, 24…230 V AC/DC power supply, Input : I/U universal, Output : I/U universal
Order No.
1481960000
Type
ACT20P-PRO DCDC II-P
GTIN (EAN)
4050118291025
Qty.
1 pc(s).
Dimensions and weights
Depth
113.7 mm
Depth (inches)
4.476 inch
Height
127.1 mm
Height (inches)
5.004 inch
Width
12.5 mm
Width (inches)
0.492 inch
Net weight
130 g
Temperatures
Operating temperature
-20 °C...60 °C
Humidity at operating temperature
0...95 % (no condensation)
Probability of failure
SIL in compliance with IEC 61508
None
MTBF
76 a
Environmental Product Compliance
REACH SVHC
Lead 7439-92-1
SCIP
2f6dd957-421a-46db-a0c2-cf1609156924
Input
Input current
configurable, ± 0.1mA...± 100 mA, Measuring range min. 200 µA
Input resistance, current
<5 mA: approx. 100 Ω; >5 mA: approx. 5 Ω
Input resistance, voltage
approx. 1 MΩ
Input voltage
configurable, ±40 mV…±300 V, Measuring range. min 40 mV
Number of inputs
1
Sensor
4- wire sensor (with own power supply)
Output
Cut-off frequency (-3 dB)
> 10 kHz/ <10 Hz
Load impedance current
≤ 600 Ω
Offset current
20 µA
Offset voltage
<10 mV
Output current
configurable, 0...±20 mA
Output voltage, note
Adjustable, 0...±10 V
Type
active (as current source) or passive (as current sink), connected control can be active / passive
load impedance voltage
≥ 1 kΩ
Display
Display value
current measured value, Configuration data
Type
Dot-matrix display with ticker text, green
General data
Accuracy
<0.05 % of measuring range
Configuration
DIP switch, or via display and push-buttons
Galvanic isolation
3-way isolator, between input ⁄ output ⁄ supply
Power consumption
≤2.3 W
Rail
TS 35
Step response time
≤50 µs
Temperature coefficient
≤0.01% of the output measurement range ⁄ °C
Voltage supply
24…230 V DC ±20 %, 24…230 V AC ±10 % @ 48…62 Hz
Insulation coordination
EMC standards
EN 61326-1
Galvanic isolation
3-way isolator, between input ⁄ output ⁄ supply
Impulse withstand voltage
5 kV (1.2/50 µs)
Insulation voltage
4 kVeff , input / output / power supply
Pollution severity
2
Rated voltage
600 V
Surge voltage category
II
Data for Ex applications (ATEX)
Marking
II 3 G Ex nA IIC T4 Gc
Connection data
Type of connection
PUSH IN
Tightening torque, min.
0.4 Nm
Tightening torque, max.
0.6 Nm
Clamping range, rated connection
2.5 mm²
Clamping range, min.
0.5 mm²
Clamping range, max.
2.5 mm²
Wire connection cross section AWG, min.
AWG 26
Wire connection cross section AWG, max.
AWG 14
Wire cross-section, solid, min.
0.5 mm²
Wire cross-section, solid, max.
2.5 mm²
Wire connection cross section, finely stranded, min.
0.5 mm²
Wire connection cross section, finely stranded, max.
2.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.
0.2 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.
2.5 mm²
Important note
Product information
The universally configurable DC isolating amplifier ACT20P-PRO DCDC II isolates and converts analogue signals. An analogue input signal (current or voltage) is linearly converted into an analogue output signal (current or voltage) and galvanically isolated. The power supply is galvanically isolated from the input and output (3-way isolation).
Properties
universal wide-range voltage supply
universally configurable via DIP switch or via the LED display using control buttons
Active or passive signal output
Operating status display on a front panel LED
Galvanic 3-way isolation between input, output and supply.
Downloads
Approval/Certificate/Document of Conformity
Engineering Data
CADENAS eCATALOG
CAX data
Software
User Documentation
Catalogues
Catalogues in PDF-format
Classifications
ETIM 6.0
EC002653
ETIM 7.0
EC002653
ETIM 8.0
EC002653
ETIM 9.0
EC002653
ECLASS 9.0
27-21-01-20
ECLASS 9.1
27-21-01-20
ECLASS 10.0
27-21-01-20
ECLASS 11.0
27-21-01-20
ECLASS 12.0
27-21-01-20
ECLASS 13.0
27-21-01-20
Type of connection:
Screw connection
Order No.:
1481970000
Type:
ACT20P-PRO DCDC II-S
Version:
Signal converter/insulator, 24…230 V AC/DC power supply, Input : I/U universal, Output : I/U universal
Type of connection:
Screw connection
Order No.:
2816690000
Type:
ACT20P-PRO DCDC II-24-S
Version:
Analogue signal converter, 24 V DC power supply, Input : I/U universal, Output : I/U universal
Type of connection:
PUSH IN
Order No.:
2816700000
Type:
ACT20P-PRO DCDC II-24-P
Version:
Analogue signal converter, 24 V DC power supply, Input : I/U universal, Output : I/U universal
Type of connection:
Screw connection
Order No.:
1453210000
Type:
ACT20P-UI-AO-DO-LP
Version:
Limit value monitoring, Input : universal U, I, R,ϑ, Output : 4-20 mA, (loop powered), Transistor (Alarm)
Type of connection:
PUSH IN
Order No.:
2456850000
Type:
ACT20P-UI-AO-DO-LP-P
Version:
Signal converter/insulator, Limit value monitoring, Input : universal U, I, R,ϑ, Output : 4-20 mA, (loop powered), Transistor (Alarm)
Type of connection:
Screw connection
Order No.:
1477420000
Type:
ACT20P-AI-AO-DC-S
Version:
Signal converter/insulator, Input : I/U universal, Output : I/U universal, Signal converter/isolator, 24 V DC power supply
Type of connection:
PUSH IN
Order No.:
2456860000
Type:
ACT20P-AI-AO-DC-P
Version:
Signal converter/insulator, Input : I/U universal, Output : I/U universal, Signal converter/isolator, 24 V DC power supply
Type of connection:
Screw connection
Order No.:
1545720000
Type:
ACT20P-AI-AO-AC-S
Version:
Signal converter/insulator, Input : I/U universal, Output : I/U universal, Signal converter/isolator, 90…264 V AC power supply
Type of connection:
PUSH IN
Order No.:
2495700000
Type:
ACT20P-AI-AO-AC-P
Version:
Signal converter/insulator, Input : I/U universal, Output : I/U universal, Signal converter/isolator, 90…264 V AC power supply
Version
Signal converter/insulator, 24…230 V AC/DC power supply, Input : I/U universal, Output : I/U universal
Order No.
1481960000
Type
ACT20P-PRO DCDC II-P
GTIN (EAN)
4050118291025
Qty.
1 pc(s).
Depth
113.7 mm
Depth (inches)
4.476 inch
Height
127.1 mm
Height (inches)
5.004 inch
Width
12.5 mm
Width (inches)
0.492 inch
Net weight
130 g
Operating temperature
-20 °C...60 °C
Humidity at operating temperature
0...95 % (no condensation)
SIL in compliance with IEC 61508
None
MTBF
76 a
REACH SVHC
Lead 7439-92-1
SCIP
2f6dd957-421a-46db-a0c2-cf1609156924
Input current
configurable, ± 0.1mA...± 100 mA, Measuring range min. 200 µA
Input resistance, current
<5 mA: approx. 100 Ω; >5 mA: approx. 5 Ω
Input resistance, voltage
approx. 1 MΩ
Input voltage
configurable, ±40 mV…±300 V, Measuring range. min 40 mV
Number of inputs
1
Sensor
4- wire sensor (with own power supply)
Cut-off frequency (-3 dB)
> 10 kHz/ <10 Hz
Load impedance current
≤ 600 Ω
Offset current
20 µA
Offset voltage
<10 mV
Output current
configurable, 0...±20 mA
Output voltage, note
Adjustable, 0...±10 V
Type
active (as current source) or passive (as current sink), connected control can be active / passive
load impedance voltage
≥ 1 kΩ
Display value
current measured value, Configuration data
Type
Dot-matrix display with ticker text, green
Accuracy
<0.05 % of measuring range
Configuration
DIP switch, or via display and push-buttons
Galvanic isolation
3-way isolator, between input ⁄ output ⁄ supply
Power consumption
≤2.3 W
Rail
TS 35
Step response time
≤50 µs
Temperature coefficient
≤0.01% of the output measurement range ⁄ °C
Voltage supply
24…230 V DC ±20 %, 24…230 V AC ±10 % @ 48…62 Hz
EMC standards
EN 61326-1
Galvanic isolation
3-way isolator, between input ⁄ output ⁄ supply
Impulse withstand voltage
5 kV (1.2/50 µs)
Insulation voltage
4 kVeff , input / output / power supply
Pollution severity
2
Rated voltage
600 V
Surge voltage category
II
Marking
II 3 G Ex nA IIC T4 Gc
Type of connection
PUSH IN
Tightening torque, min.
0.4 Nm
Tightening torque, max.
0.6 Nm
Clamping range, rated connection
2.5 mm²
Clamping range, min.
0.5 mm²
Clamping range, max.
2.5 mm²
Wire connection cross section AWG, min.
AWG 26
Wire connection cross section AWG, max.
AWG 14
Wire cross-section, solid, min.
0.5 mm²
Wire cross-section, solid, max.
2.5 mm²
Wire connection cross section, finely stranded, min.
0.5 mm²
Wire connection cross section, finely stranded, max.
2.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.
0.2 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.
2.5 mm²
Product information
The universally configurable DC isolating amplifier ACT20P-PRO DCDC II isolates and converts analogue signals. An analogue input signal (current or voltage) is linearly converted into an analogue output signal (current or voltage) and galvanically isolated. The power supply is galvanically isolated from the input and output (3-way isolation).
Properties
universal wide-range voltage supply
universally configurable via DIP switch or via the LED display using control buttons
Active or passive signal output
Operating status display on a front panel LED
Galvanic 3-way isolation between input, output and supply.
ETIM 6.0
EC002653
ETIM 7.0
EC002653
ETIM 8.0
EC002653
ETIM 9.0
EC002653
ECLASS 9.0
27-21-01-20
ECLASS 9.1
27-21-01-20
ECLASS 10.0
27-21-01-20
ECLASS 11.0
27-21-01-20
ECLASS 12.0
27-21-01-20
ECLASS 13.0
27-21-01-20
Approvals
Approvals
CULUS;GERMLLOYD;
ROHS
Conform
UL File Number Search
UL Website
Certificate no. (cULus)
E314307
Certificate no. (cULusEX)
E345958
Type of connection:
Screw connection
Order No.:
1481970000
Type:
ACT20P-PRO DCDC II-S
Version:
Signal converter/insulator, 24…230 V AC/DC power supply, Input : I/U universal, Output : I/U universal
Type of connection:
Screw connection
Order No.:
2816690000
Type:
ACT20P-PRO DCDC II-24-S
Version:
Analogue signal converter, 24 V DC power supply, Input : I/U universal, Output : I/U universal
Type of connection:
PUSH IN
Order No.:
2816700000
Type:
ACT20P-PRO DCDC II-24-P
Version:
Analogue signal converter, 24 V DC power supply, Input : I/U universal, Output : I/U universal
Type of connection:
Screw connection
Order No.:
1453210000
Type:
ACT20P-UI-AO-DO-LP
Version:
Limit value monitoring, Input : universal U, I, R,ϑ, Output : 4-20 mA, (loop powered), Transistor (Alarm)
Type of connection:
PUSH IN
Order No.:
2456850000
Type:
ACT20P-UI-AO-DO-LP-P
Version:
Signal converter/insulator, Limit value monitoring, Input : universal U, I, R,ϑ, Output : 4-20 mA, (loop powered), Transistor (Alarm)
Type of connection:
Screw connection
Order No.:
1477420000
Type:
ACT20P-AI-AO-DC-S
Version:
Signal converter/insulator, Input : I/U universal, Output : I/U universal, Signal converter/isolator, 24 V DC power supply
Type of connection:
PUSH IN
Order No.:
2456860000
Type:
ACT20P-AI-AO-DC-P
Version:
Signal converter/insulator, Input : I/U universal, Output : I/U universal, Signal converter/isolator, 24 V DC power supply
Type of connection:
Screw connection
Order No.:
1545720000
Type:
ACT20P-AI-AO-AC-S
Version:
Signal converter/insulator, Input : I/U universal, Output : I/U universal, Signal converter/isolator, 90…264 V AC power supply
Type of connection:
PUSH IN
Order No.:
2495700000
Type:
ACT20P-AI-AO-AC-P
Version:
Signal converter/insulator, Input : I/U universal, Output : I/U universal, Signal converter/isolator, 90…264 V AC power supply
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.