ACT20X-HUI-SAO-LP-S   Do not use product for new developments
         

Icon
Icon
Icon
Icon
Icon
Icon
Icon
Icon
Icon
 

General ordering data

Version ACT20X, EX signal isolating converter, 1-channel version, Output-loop powered
Order No. 1318220000
Type ACT20X-HUI-SAO-LP-S
GTIN (EAN) 4050118323955
Qty. 1 pc(s).
Delivery status This article will no longer be available in the future.
Available until 2021-12-15

Dimensions and weights

Depth 113.6 mm
Depth (inches) 4.472 inch
Height 117.2 mm
Height (inches) 4.614 inch
Width 12.5 mm
Width (inches) 0.492 inch
Net weight 171 g

Temperatures

Storage temperature -20 °C...70 °C
Operating temperature 0 °C...60 °C
Humidity at operating temperature 0...95 % (no condensation)
Humidity 10…90 %, no condensation

Probability of failure

SIL in compliance with IEC 61508 2

Environmental Product Compliance

REACH SVHC Lead 7439-92-1
SCIP 2f6dd957-421a-46db-a0c2-cf1609156924

Assembling

Mounting position horizontal or vertical
Rail TS 35
Type of mounting DIN rail

Input EX

Input current configurable, ± 25 mA, 0...20 mA, 4…20mA
Input resistance 0…12 kΩ
Input resistance, current 70 Ω
Input resistance, voltage > 10 MΩ @ 600 mV, 2 MΩ @ 28 V
Input voltage configurable, ± 12 V DC (min. measurement range 1 V), ± 28 V DC (min. measurement range 2 V), ± 600 mV DC (min. measurement range 50 mV), ± 150 mV DC (min. measurement range 15 mV)
Line resistance in measuring circuit ≤ 50 Ω
Potentiometer 1.2…500 kΩ
Sensor 2-/3-/4-wire, RTD: PT10, PT20, PT50, PT100, PT250, PT300, PT400, PT500, PT1000, Ni50, Ni100, Ni120, Ni1000, Thermocouples: B, E, J, K, N, R, S, T ; in compliance with IEC 60584-1 and L, U in compliance with DIN43710, Potentiometer, Resistance: 0 - 12 kΩ
Sensor supply 28…16.5 V DC / 0…20 mA
Temperature input range Adjustable from -200...+800°C
Type intrinsically safe circuit

Output

Cut-off frequency (-3 dB) 100 Hz
Load impedance current ≤ 700 Ω
Output current 4…20 mA (max. 23 mA)
Output signal limit 3.8…20.5 mA / 0…20.5 mA (dependent on range)
Type Output-loop powered

General specifications

Accuracy <0.1 % of end value
Configuration With FDT/DTM software, Requires configuration adapter 8978580000 CBX200 USB
Humidity 10…90 %, no condensation
Power consumption ≤ 3.5 W
Protection degree IP20
Step response time 250 ms (10…90%)
Temperature coefficient <0.02 °C of measuring range / °C
Type of connection Screw connection
Voltage supply via output current loop, 11…28 V DC (loop powered)

Insulation coordination

Impulse withstand voltage 4 kV (1.2/50 µs)
Insulation voltage 3.51 kV between input and output
Pollution severity 2
Rated voltage 300 Veff
Standards DIN EN 61326-1, IEC 61010-1, IEC 61010-2-030, IEC 60079-0, IEC 60079-11, IEC 60079-15, IEC 60079-26
Surge voltage category III

Data for Ex applications (ATEX)

Current I0 88.2 mA
Installation location Device installed in safe area, zone 2
Marking II 3 G Ex nA IIC T4 Gc, I (M1) [Ex ia Ma] I, II (1) D [Ex ia Da] IIIC
Power P0 129 mW
Voltage U0 5.88 V DC

Safety-related basic specifications

Safety category SIL 2

Connection data

Type of connection Screw connection
Tightening torque, min. 0.4 Nm
Tightening torque, max. 0.6 Nm
Clamping range, rated connection 2.5 mm²
Clamping range, min. 0.25 mm²
Clamping range, max. 2.5 mm²
Wire connection cross section AWG, min. AWG 26
Wire connection cross section AWG, max. AWG 12

Guarantee

Time interval 3 years

Downloads

Classifications

ETIM 6.0 EC002653
ETIM 7.0 EC002653
ETIM 8.0 EC002653
ETIM 9.0 EC002653
ECLASS 9.0 27-21-01-20
ECLASS 9.1 27-21-01-20
ECLASS 10.0 27-21-01-20
ECLASS 11.0 27-21-01-20
ECLASS 12.0 27-21-01-20
ECLASS 13.0 27-21-01-20

Tender specification sheets

Long specification

Ex universal measurement isolating transformer for RTD-/ TC temperature and DC-current-/ voltage signals,
output-loop powered
1-channel 4...20 mA output-loop powered measurement isolating transformer in 12.5 mm width for recording,
isolating and transmitting RTD- / TC sensors, resistors, potentiometers and DC current signals
and voltages from Ex zones 0,1,2 to the safe zone.
The component can be configured using standard FDT/DTM software.

Add-on housing for TS35 rail mounting
Dimensions: L/W/H 119.2/ 12.5/ 113.6
Screw connection/ Nominal cross-section 2.5 mm2
Protection degree: IP 20  


Input                          RTD: PT200, PT1000, Ni120, Cu100
                                       Resistance 0...15 kOhm / Potentiometer 1.2...500 kOhm
                                       TC- Type: B, E, J, K, L, N, R, S, T,U
                                       +/- 25 mA configurable
                                       +/- 28 V configurable                                    
Output                          4...20 mA current loop
Load                              < 700 Ohm
Accuracy                    < 0,1 % v.E
Auxiliary power                                       11...28 VDC / current loop
Power loss approx. 1.5 W
Ambient
temperature range 0 °C...+60 °C

Secure isolation                     EN 50178, 2-way isolation up to 4kV
Working voltage                     300 V AC/DC at overvoltage category II and pollution degree 2
Approvals cULus, ATEX IECEX, Class1, Div1

IECEx marking (Exia)I IIC / I T4
Ex characteristic data U0 = 5.88 V DC
                                      I0  = 82.3 mA DC
                                      P0 = 121 mW

Type
                                                             ACT20X-HUI-SAO-LP-S


Short specification

Ex universal measurement isolating transformer for RTD-/ TC temperature and DC-current-/ voltage signals,
output-loop powered
1-channel 4...20 mA- loop-powered measurement isolating transformer in 12.5 mm width for recording,
isolating and transmitting RTD- / TC sensors, resistors, potentiometers and DC current signals
and voltages from Ex zones 0,1,2 to the safe zone.
The component can be configured using standard FDT/DTM software.

Approvals

Approvals CE TUEVSATEX
Approvals CULUS; EAC; IECEXKEM; ATEX
ROHS Conform

Related products

Type of connection: Screw connection
Order No.: 8965490000
Type: ACT20X-HUI-SAO-S
Version:
EX signal isolating converter, Ex-output: U, I, R,ϑ, Safe-output: 4-20mA/ relay, 1-channel
 
Type of connection: PUSH IN
Order No.: 2456200000
Type: ACT20X-HUI-SAO-P
Version:
EX signal isolating converter, Ex-output: U, I, R,ϑ, Safe-output: 4-20mA/ relay, 1-channel
 
Contact
Weidmüller Interface GmbH & Co. KG
 
+49 5231 14-0
+49 5231 14-292083
More information
Decentralised automation solutions
Energy Management Solutions
Industrial Analytics
Industrial IoT Solutions
More information
Mobility Concepts
Photovoltaics
Wind Solutions
Workplace Solutions
More information
Single Pair Ethernet
Weidmüller Configurator
Support & Service
Contact
Disposal Instructions
Engineering data
Repairs and replacement parts