ACT20M-CI-2CO-S
         

Icon
Icon
Icon
Icon
Icon
Icon
 

General ordering data

Version Signal splitter, Signal distributor, Input : 0(4)-20 mA, Output : 2 x 0(4) - 20 mA
Order No. 1175990000
Type ACT20M-CI-2CO-S
GTIN (EAN) 4032248969982
Qty. 1 pc(s).

Dimensions and weights

Depth 114.3 mm
Depth (inches) 4.5 inch
Height 112.5 mm
Height (inches) 4.429 inch
Width 6.1 mm
Width (inches) 0.24 inch
Net weight 83.6 g

Temperatures

Storage temperature -40 °C...85 °C
Operating temperature -25 °C...70 °C
Humidity at operating temperature 0...95 % (no condensation)
Humidity 40 °C / 93 % rel. humidity, no condensation

Probability of failure

SIL in compliance with IEC 61508 None
MTBF 219 a

Environmental Product Compliance

REACH SVHC Lead 7439-92-1
SCIP 2f6dd957-421a-46db-a0c2-cf1609156924

Input

Input current 0...20 mA, 4...20 mA
Input resistance, current 70 Ω
Number of inputs 1
Sensor Current source, Sensor with own supply, 4-wire sensor
Voltage drop, current input <1.5 V

Output

Cut-off frequency (-3 dB) 100 Hz
Load impedance current <300 Ω, per channel, @ max 23mA
Number of outputs 2
Output current 0...20 mA, 4...20 mA
Type active, connected control must be passive

General data

Accuracy <0.05 % of measuring range
Configuration none
Galvanic isolation 3-way isolator
Power consumption, max. 0.8 W
Power consumption, typ. 0.45 W
Rail TS 35
Step response time ≤ 7 ms
Temperature coefficient ≤ 0.01 % / °C
Voltage supply 24 V DC ±30 % at terminal or via CH20M rail bus

Insulation coordination

EMC standards IEC 61326-1, NE 21
Galvanic isolation 3-way isolator
Insulation voltage 2.5 kVeff /1 min.
Pollution severity 2
Rated voltage 300 Veff
Surge voltage category II

Data for Ex applications (ATEX)

Installation location Device installed in safe area, zone 2
Marking II 3 G Ex nA IIC T4 Gc

Connection data

Type of connection Screw connection
Tightening torque, min. 0.4 Nm
Tightening torque, max. 0.6 Nm
Clamping range, rated connection 2.5 mm²
Clamping range, min. 0.5 mm²
Clamping range, max. 2.5 mm²
Wire connection cross section AWG, min. AWG 30
Wire connection cross section AWG, max. AWG 14

EMC conformity and approvals

EMC standards IEC 61326-1, NE 21
Safety standard UL 61010-1
Ship use DNV-GL
Standards ATEX, EN 60079-0, IECEX, IEC 60079-0

Important note

Product information The non-adjustable DC isolating amplifier ACT20M-CI-CO-S isolates analogue standard current signals. An analogue input current signal is linearly converted to an analogue output current signal and is galvanically isolated. The power supply is galvanically isolated from the input and output (3-way isolation) by means of direct wiring or the Weidmüller rail bus.

The non-adjustable DC isolation amplifier ACT20M CI-2CO-S offers the same functionality, but has 2 galvanically isolated outputs (4-way isolation).

Downloads

Approval/Certificate/Document of Conformity
Engineering Data
Engineering Data Zuken E3.S
Eplan Data Portal Eplan data
CADENAS eCATALOG CAX data
WSCAD Universe WSCAD data
User Documentation
Catalogues Catalogues in PDF-format
Brochures

Classifications

ETIM 6.0 EC002653
ETIM 7.0 EC002653
ETIM 8.0 EC002653
ETIM 9.0 EC002653
ECLASS 9.0 27-21-01-20
ECLASS 9.1 27-21-01-20
ECLASS 10.0 27-21-01-20
ECLASS 11.0 27-21-01-20
ECLASS 12.0 27-21-01-20
ECLASS 13.0 27-21-01-20

Tender specification sheets

Long specification

Standard signal splitter
1-channel signal splitter in 6.1 mm width with external power supply,
to transmit, isolate and split analogue DC current signals 0/4...20 mA

Add-on housing for TS35 rail mounting
Dimensions: L/W/H 114.3/ 6.1/ 112.5 mm
Screw connection / Nominal cross-section 2.5 mm2
Protection degree: IP 20  


Input                          0/4...20 mA

Output                                              2 x 0/4...20 mA
Load resistance             < 300 Ohm/ Ausgang
Transmission error             < 0,05 % v. E. 
Limit frequency 100 Hz 
Auxiliary power                                     24 VDC +/- 30 %
Power loss approx. 0.8 W
Ambient
temperature range -25 °C...+70 °C

Isolation                                 EN 61010-1, 3-way isolation up to 2.5 kV AC/DC of all circuits against each other
Test voltage                               2.5 kV input against output against auxiliary power
Rated
voltage                                        
  300 V AC/DC at overvoltage category II and pollution degree 2
Approvals cULus, FM Div2, ATEX Zone2, DNV, GL




Type                                                             ACT20M-CI-2CO-S

Short specification

Standard signal splitter
1-channel signal splitter in 6.1 mm width with external power supply,
to transmit, isolate and split analogue DC current signals 0/4 to 20 mA

Approvals

Approvals CCCEX CE CULUS DETNORVER FMEX IECEXKEM KEMAATEX UKEX
ROHS Conform
UL File Number Search UL Website
Certificate no. (cULus) E337701

Related products

Type of connection: Screw connection
Order No.: 1176020000
Type: ACT20M-AI-2AO-S
Version:
Signal splitter, Configurable, with sensor supply, Input : I / U, Output : 2 x I/U
 
Type of connection: Screw connection
Order No.: 1375470000
Type: ACT20M-BAI-2AO-S
Version:
Signal splitter, Configurable, Input : I/U/bidirectional I, Output : 2 x I/U or 1 x bidirectional
 
Contact
Weidmüller Interface GmbH & Co. KG
 
+49 5231 14-0
+49 5231 14-292083
More information
Decentralised automation solutions
Energy Management Solutions
Industrial Analytics
Industrial IoT Solutions
More information
Mobility Concepts
Photovoltaics
Wind Solutions
Workplace Solutions
More information
Single Pair Ethernet
Weidmüller Configurator
Support & Service
Contact
Disposal Instructions
Engineering data
Repairs and replacement parts