ACT20P BRIDGE
         

Icon
Icon
Icon
Icon
Icon
Icon
 

General ordering data

Version Measuring bridge converter, Input : Resistance measuring bridge, Output : 0(4)-20 mA, 0-10 V
Order No. 1067250000
Type ACT20P BRIDGE
GTIN (EAN) 4032248820856
Qty. 1 pc(s).

Dimensions and weights

Depth 113.6 mm
Depth (inches) 4.472 inch
Height 119.2 mm
Height (inches) 4.693 inch
Width 22.5 mm
Width (inches) 0.886 inch
Net weight 198 g

Temperatures

Storage temperature -40 °C...85 °C
Operating temperature -40 °C...70 °C
Humidity 10…90 %, no condensation

Probability of failure

SIL in compliance with IEC 61508 None
MTTF 543 a

Environmental Product Compliance

REACH SVHC Lead 7439-92-1
SCIP 2f6dd957-421a-46db-a0c2-cf1609156924

Input

Bridge sensitivity 1.0 mV / V to 5.0 mV / V
Bridge supply voltage 5 V or 10 V
Input signal ±10 mV / ±20 mV / ±30 mV / ±50 mV
Number of inputs 1
Sensor Strain gauge resistance, Resistance measurement, Total resistance of all parallel resistance measuring bridges: min. 87 Ω
Sensor supply 120 mA @ 10 V (= 4 x 350 Ω bridge resistors)

Output

Load impedance current ≤ 600 Ω
Output current 0…22 mA (adjustable)
Output voltage, note 0…11 V (adjustable)
Type active, connected control must be passive
load impedance voltage 600 Ω

Output (digital)

Max. switching voltage, AC 0 V
Rated switching current 0.1 A

Output (analogue)

Output current 0…22 mA (adjustable)

General data

Accuracy <0.05 % of measuring range
Configuration DIP switch and button
Linearity Typically ± 0.05 % of signal range
Long-term drift 0.1 % / 10.000 h
Power consumption 3 W @ 24 V DC
Rail TS 35
Step response time <400 ms (10…90 %)
Temperature coefficient typ. 0.005 % / °C
Voltage supply 10…60 V DC

Insulation coordination

EMC standards EN 61326
Insulation voltage 5.7 kV (input / output, input / supply)
Pollution severity 2
Rated voltage 300 V
Surge voltage category III

Connection data

Type of connection Screw connection
Tightening torque, min. 0.4 Nm
Tightening torque, max. 0.6 Nm
Clamping range, rated connection 2.5 mm²
Clamping range, min. 0.5 mm²
Clamping range, max. 2.5 mm²
Wire connection cross section AWG, min. AWG 26
Wire connection cross section AWG, max. AWG 12

Important note

Product information The ACT20P-BRIDGE-S bridge measuring transducer converts measuring bridge voltages into standard signals. Buttons are used for adjustment to the measuring bridge connected. The bridge measuring transducer can supply up to 4 parallel-connected measuring bridges each with 350 Ω. The device supports simple compensation of the tare weight with a separate input for an external button or an external PLC signal. The power supply is electrogalvanised and isolated from the input and output (3-way isolation).

Properties
  • 4-wire and 6-wire measurement
  • Supply of up to 4 parallel-connected measuring bridges each with 350 Ω
  • Input and output ranges can be adjusted via DIP switches
  • Tara compensation via external button or PLC signal
  • Operating status display on a front panel LED
  • Galvanic 3-way isolation between input, output and supply.

Downloads

Approval/Certificate/Document of Conformity
Engineering Data
Eplan Data Portal Eplan data
CADENAS eCATALOG CAX data
WSCAD Universe WSCAD data
Software
User Documentation
Catalogues Catalogues in PDF-format
Brochures

Classifications

ETIM 6.0 EC002653
ETIM 7.0 EC002653
ETIM 8.0 EC002653
ETIM 9.0 EC002653
ECLASS 9.0 27-21-01-20
ECLASS 9.1 27-21-01-20
ECLASS 10.0 27-21-01-20
ECLASS 11.0 27-21-01-20
ECLASS 12.0 27-21-01-20
ECLASS 13.0 27-21-01-20

Tender specification sheets

Long specification

Bridge measuring transformer with electrical 3-way isolation, configurable
measurement isolating transformer in 22.5 mm width with external power supply, for recording,
transforming and isolating of measurements from industrial strain gauges.
Standard DC current/voltage signals are available on the output side. Measuring bridges of up to
3 x 350 Ohm can be supplied via the input circuit. Automatic tare calibration
via external switch signal, or manually with a press of a button.
6-wire connection compensates for differences in wire resistance. Bridge excitation voltage
can be switched between 5 v and 10 V
. Load cells can be calibrated using a button on the front side.
I/O signals can be configured via DIP switches.


Add-on housing for TS35 rail mounting
Dimensions: L/W/H 119.2/ 22.5/ 113.6 mm
Screw connection / Nominal cross-section 2.5 mm2
Protection degree: IP 20 

Input                          Resistance measuring bridge / 1 mV / V... 5 mV / V
Bridge sensitivity +/- 10 mV / +/- 20 mV / +/- 30 mV / +/- 50 mV (adjustable)
Input resistance > 1 MOhm
Bridge supply 5 V or 10 V  
                                                                                                                                                                                                      
Output                                              0...11 V / 0...22 mA configurable                                       
Load resistance             < 600 Ohm/ Strom/> 1 kOhm/ voltage
Temperature coefficient typ. 50 ppm / K
Transmission error               typ. 0.05 % of input
Step response time         < 400 ms (10...90 %)
Auxiliary
power                                     10...60 VDC 
Ambient
temperature range -40°C...+70 °C


Isolation                                 EN 50178, 3-way isolation up to 5.7 kV of all circuits against each other
Test voltage                               4 kV input against output against auxiliary power
Rated
voltage                                        
  300 V AC/DC at overvoltage category III and pollution degree 2
Approvals cULus




Type                                                             ACT20P-BRIDGE-S

Short specification

Bridge measuring transformer with electrical 3-way isolation, configurable
measurement isolating transformer in 22.5 mm width with external power supply, for recording,
transforming and isolating of measurements from industrial strain gauges.
Standard DC current/voltages signals are available on the output side. Measuring bridges of up to
3 x 350 Ohm can be supplied via the input circuit. Automatic tare calibration
via external switch signal, or manually with a press of a button.
6-wire connection compensates for differences in wire resistance. Bridge excitation voltage
can be switched between 5 v and 10 V
. Load cells can be calibrated using a button on the front side.
I/O signals can be configured via DIP switches.

Approvals

Approvals CE
Approvals CULUS;
ROHS Conform

Related products

Type of connection: PUSH IN
Order No.: 2456820000
Type: ACT20P-BRIDGE-P
Version:
Measuring bridge converter, Input : Resistance measuring bridge, Output : 0(4)-20 mA, 0-10 V
 
Contact
Weidmüller Interface GmbH & Co. KG
 
+49 5231 14-0
+49 5231 14-292083
More information
Decentralised automation solutions
Energy Management Solutions
Industrial Analytics
Industrial IoT Solutions
More information
Mobility Concepts
Photovoltaics
Wind Solutions
Workplace Solutions
More information
Single Pair Ethernet
Weidmüller Configurator
Support & Service
Contact
Disposal Instructions
Engineering data
Repairs and replacement parts