Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Analogue Signal Conditioning
Power Supplies
Electronics Housings
Lightning and Surge Protection
Photovoltaics
e-mobility
Fieldbus Distributors
Network-compatible current measuring transducers ACT20C
intrinsically safe signal converter - ACT20X
signal converter and process monitoring - ACT20P
Space-saving signal converter - ACT20M
Signal converter in terminal block format - MCZ
Compact standard signal isolators - PicoPak
Signal - & serial interface converter– WAVESERIES
Process monitoring displays
Analogue-digital / digital-analogue converter
Configuration software
Accessories
HART® transparent repeater
HART® transparent driver
Temperature & mA converter
Pulse isolator with relay output
Pulse isolator with transistor output
Solenoid valve switch & alarm transmitter
Universal converter
General ordering data
Version
EX signal isolating converter, Ex-input: NAMUR sensor/switch, Safe-output: relay, NO contact, 1-channel
Order No.
8965340000
Type
ACT20X-HDI-SDO-RNO-S
GTIN (EAN)
4032248784851
Qty.
1 pc(s).
Dimensions and weights
Depth
113.6 mm
Depth (inches)
4.472 inch
Height
119.2 mm
Height (inches)
4.693 inch
Width
22.5 mm
Width (inches)
0.886 inch
Net weight
177 g
Temperatures
Storage temperature
-20 °C...85 °C
Operating temperature
-20 °C...60 °C
Humidity
0...95 % (no condensation)
Probability of failure
SIL PAPER
SIL certificate
SIL in compliance with IEC 61508
2
MTBF
207 a
Environmental Product Compliance
REACH SVHC
Lead 7439-92-1
SCIP
2f6dd957-421a-46db-a0c2-cf1609156924
Assembling
Mounting position
horizontal or vertical
Rail
TS 35
Type of mounting
Snap mounting support rail
Input EX
Input frequency
<20 Hz
Input resistance
1 kΩ
Output signal in case of wire break
<0.1 mA, > 6.5 mA (in case of wire break)
Pulse duration
> 0.1 ms
Resistance
RP = 750 Ω / RS = 15kΩ
Sensor
NAMUR sensor, according to EN60947-5-6, switch with or without RS, RP
Sensor supply
8 V DC / 8 mA
Trigger level high
> 2.1 mA
Trigger level low
<1.2 mA
Type
intrinsically safe circuit
Digital output
Continuous current
≤ 2 A AC/DC (safe area, Zone 2 area)
Function
Output = input, direct or inverse (configurable)
Max. switching frequency
20 Hz
Nominal switching voltage
≤ 250 V AC / 30 V DC (safe area) ≤ 32 V AC / 32 V DC (zone 2)
Switching capacity
500 VA / 60 W (safe area), 16 VA / 60 W (zone 2)
Type
Relay, 1 NO, Switching frequency 20 Hz
Alarm output
Alarm function
Line interruption at the input, Short circuit at input, No supply voltage, Device error
Continuous current
≤ 0.5 A AC / 0.3 A DC (safe zone), ≤ 0,5 A AC / 1 A DC (zone 2)
Nominal switching voltage
≤ 125 V AC / 110 V DC (safe area) ≤ 32 V AC / 32 V DC (zone 2)
Power rating
≤ 62.5 VA / 32 W (safe area) ≤ 16 VA / 32 W (Zone 2)
Type
Status relay, 1 NC (voltage-free)
General specifications
Configuration
With FDT/DTM software, Requires configuration adapter 8978580000 CBX200 USB
Humidity
0...95 % (no condensation)
NAMUR supply
8 V DC / 8 mA
Power consumption
≤ 1.3 W
Protection degree
IP20
Type of connection
Screw connection
Voltage supply
19.2…31.2 V DC
Insulation coordination
EMC standards
EN 61326-1
Insulation voltage
2.6 kV (input / output)
Rated voltage
300 V
Standards
EN 61010-1
Data for Ex applications (ATEX)
Current I0
12 mA DC
Installation location
Device installed in safe area, zone 2
Marking
II (1) G [Ex ia Ga] IIC/IIB/IIA, II (1) D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I
Power P0
32 mW
Voltage U0
10.6 V DC
Safety-related basic specifications
Description of the "safe state"
de-energized (relay output)
Device type
B
Diagnostic test interval
10 s
Tproof
4 a
Total failure rate for safe detected failures (λSD )
0 FIT
Hardware fault tolerance (HFT)
0
Safety category
SIL 2
Relay lifetime
100000 times
Safe Failure Fraction (SFF)
90 %
Mean Time To Repair (MTTR)
8 h
Total failure rate for safe undetected failures (λSU )
289 FIT
Total failure rate for dangerous detected failures (λDD )
130 FIT
Total failure rate for dangerous undetected failures (λDU )
46 FIT
Probability of outage PFH
4.66 x 10-8 h-1
Demand mode
High
Demand rate
1,000 s
Demand response time
<10 ms (relay output)
Safety-related specifications Low demand mode
Safe Failure Fraction (SFF)
90 %
Average Probability of Failure on Demand (PFDavg )
2.04 x 10-4 (Tproof = 1 year), 4.08 x 10-4 (Tproof = 2 years), 1.02 x 10-4 (Tproof = 5 years)
Connection data
Type of connection
Screw connection
Tightening torque, min.
0.4 Nm
Tightening torque, max.
0.6 Nm
Clamping range, rated connection
2.5 mm²
Clamping range, min.
0.25 mm²
Clamping range, max.
2.5 mm²
Wire connection cross section AWG, min.
AWG 26
Wire connection cross section AWG, max.
AWG 12
Guarantee
Time interval
3 years
Classifications
ETIM 6.0
EC002653
ETIM 7.0
EC002653
ETIM 8.0
EC002653
ETIM 9.0
EC002653
ECLASS 9.0
27-21-01-20
ECLASS 9.1
27-21-01-20
ECLASS 10.0
27-21-01-20
ECLASS 11.0
27-21-01-20
ECLASS 12.0
27-21-01-20
ECLASS 13.0
27-21-01-20
Tender specification sheets
Long specification
Ex isolating switch amplifiers for Namur sensors 1-channel isolating switch amplifiers in 22.5 mm width with an external power supply, to transmit and isolate Namur sensor signals from Ex zones 0,1,2 into the safe zone. On the output side there is a potential-free relay contact with closing function and an alarm contact for status/error messages. The component can be configured using standard FDT/DTM software.
Add-on housing for TS35 DIN rail installation Dimensions: L/W/H 119.2/ 22.5/ 113.6 Screw connection/ nominal cross-section 2.5 mm2 Protection degree: IP20 Input NAMUR sensor according to EN 60947 8 VDC / 8 mA sensor power supply 0 to 5 kHz input frequency wire-break detection Output Relay 1 NO contact 250 VAC / 30 VDC @ 2A safe zone 32 VAC @ 0.5 A/ 32 VDC @ 1 A zone 2 Alarm output relay 1 NO contact 250 VAC / 30 VDC @ 2A safe zone 32 VAC @ 0.5 A/ 32 VDC @ 1 A zone 2Auxiliary power 19 to 31.2 VDC Power loss approx. 1.8 W Ambient temperature range -20 °C to +60 °C
Secure isolation EN 61010, 3-way isolation up to 2.6 kV AC/DC of all circuits against each other Working voltage 300 V AC/DC at overvoltage category II and pollution degree 2 Approvals cULus, ATEX IECEX, FM ATEX marking II 3 G ExnA nC IIC T4 ATEX characteristic data U0 = 10, 6 V DC I0 = 12 mA DC P0 = 32 W Type ACT20X-HDI-SDO-RNO-S
Short specification
Ex isolating switch amplifiers for Namur sensors 1-channel isolating switch amplifiers in 22.5 mm width with an external power supply, to transmit and isolate Namur sensor signals from Ex zones 0,1,2 into the safe zone. On the output side there is a potential-free relay contact with closing function and an alarm contact for status/error messages. The component can be configured using standard FDT/DTM software.
Type of connection:
Screw connection
Order No.:
8965350000
Type:
ACT20X-HDI-SDO-RNC-S
Version:
EX signal isolating converter, Ex-input: NAMUR sensor/switch, Safe-output: relay, NC contact, 1-channel
Type of connection:
PUSH IN
Order No.:
2456060000
Type:
ACT20X-HDI-SDO-RNC-P
Version:
EX signal isolating converter, Ex-input: NAMUR sensor/switch, Safe-output: relay, NC contact, 1-channel
Type of connection:
PUSH IN
Order No.:
2456050000
Type:
ACT20X-HDI-SDO-RNO-P
Version:
EX signal isolating converter, Ex-input: NAMUR sensor/switch, Safe-output: relay, NO contact, 1-channel
Type of connection:
Screw connection
Order No.:
8965380000
Type:
ACT20X-2HDI-2SDO-RNC-S
Version:
EX signal isolating converter, Ex-input: NAMUR sensor/switch, Safe-output: relay, NC contact, 2-channel
Type of connection:
PUSH IN
Order No.:
2456090000
Type:
ACT20X-2HDI-2SDO-RNC-P
Version:
EX signal isolating converter, Ex-input: NAMUR sensor/switch, Safe-output: relay, NC contact, 2-channel
Type of connection:
Screw connection
Order No.:
8965370000
Type:
ACT20X-2HDI-2SDO-RNO-S
Version:
EX signal isolating converter, Ex-input: NAMUR sensor/switch, Safe-output: relay, NO contact, 2-channel
Type of connection:
PUSH IN
Order No.:
2456080000
Type:
ACT20X-2HDI-2SDO-RNO-P
Version:
EX signal isolating converter, Ex-input: NAMUR sensor/switch, Safe-output: relay, NO contact, 2-channel
Version
EX signal isolating converter, Ex-input: NAMUR sensor/switch, Safe-output: relay, NO contact, 1-channel
Order No.
8965340000
Type
ACT20X-HDI-SDO-RNO-S
GTIN (EAN)
4032248784851
Qty.
1 pc(s).
Depth
113.6 mm
Depth (inches)
4.472 inch
Height
119.2 mm
Height (inches)
4.693 inch
Width
22.5 mm
Width (inches)
0.886 inch
Net weight
177 g
Storage temperature
-20 °C...85 °C
Operating temperature
-20 °C...60 °C
Humidity
0...95 % (no condensation)
REACH SVHC
Lead 7439-92-1
SCIP
2f6dd957-421a-46db-a0c2-cf1609156924
Mounting position
horizontal or vertical
Rail
TS 35
Type of mounting
Snap mounting support rail
Input frequency
<20 Hz
Input resistance
1 kΩ
Output signal in case of wire break
<0.1 mA, > 6.5 mA (in case of wire break)
Pulse duration
> 0.1 ms
Resistance
RP = 750 Ω / RS = 15kΩ
Sensor
NAMUR sensor, according to EN60947-5-6, switch with or without RS, RP
Sensor supply
8 V DC / 8 mA
Trigger level high
> 2.1 mA
Trigger level low
<1.2 mA
Type
intrinsically safe circuit
Continuous current
≤ 2 A AC/DC (safe area, Zone 2 area)
Function
Output = input, direct or inverse (configurable)
Max. switching frequency
20 Hz
Nominal switching voltage
≤ 250 V AC / 30 V DC (safe area) ≤ 32 V AC / 32 V DC (zone 2)
Switching capacity
500 VA / 60 W (safe area), 16 VA / 60 W (zone 2)
Type
Relay, 1 NO, Switching frequency 20 Hz
Alarm function
Line interruption at the input, Short circuit at input, No supply voltage, Device error
Continuous current
≤ 0.5 A AC / 0.3 A DC (safe zone), ≤ 0,5 A AC / 1 A DC (zone 2)
Nominal switching voltage
≤ 125 V AC / 110 V DC (safe area) ≤ 32 V AC / 32 V DC (zone 2)
Power rating
≤ 62.5 VA / 32 W (safe area) ≤ 16 VA / 32 W (Zone 2)
Type
Status relay, 1 NC (voltage-free)
Configuration
With FDT/DTM software, Requires configuration adapter 8978580000 CBX200 USB
Humidity
0...95 % (no condensation)
NAMUR supply
8 V DC / 8 mA
Power consumption
≤ 1.3 W
Protection degree
IP20
Type of connection
Screw connection
Voltage supply
19.2…31.2 V DC
EMC standards
EN 61326-1
Insulation voltage
2.6 kV (input / output)
Rated voltage
300 V
Standards
EN 61010-1
Current I0
12 mA DC
Installation location
Device installed in safe area, zone 2
Marking
II (1) G [Ex ia Ga] IIC/IIB/IIA, II (1) D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I
Power P0
32 mW
Voltage U0
10.6 V DC
Description of the "safe state"
de-energized (relay output)
Device type
B
Diagnostic test interval
10 s
Tproof
4 a
Total failure rate for safe detected failures (λSD )
0 FIT
Hardware fault tolerance (HFT)
0
Safety category
SIL 2
Relay lifetime
100000 times
Safe Failure Fraction (SFF)
90 %
Mean Time To Repair (MTTR)
8 h
Total failure rate for safe undetected failures (λSU )
289 FIT
Total failure rate for dangerous detected failures (λDD )
130 FIT
Total failure rate for dangerous undetected failures (λDU )
46 FIT
Probability of outage PFH
4.66 x 10-8 h-1
Demand mode
High
Demand rate
1,000 s
Demand response time
<10 ms (relay output)
Safe Failure Fraction (SFF)
90 %
Average Probability of Failure on Demand (PFDavg )
2.04 x 10-4 (Tproof = 1 year), 4.08 x 10-4 (Tproof = 2 years), 1.02 x 10-4 (Tproof = 5 years)
Type of connection
Screw connection
Tightening torque, min.
0.4 Nm
Tightening torque, max.
0.6 Nm
Clamping range, rated connection
2.5 mm²
Clamping range, min.
0.25 mm²
Clamping range, max.
2.5 mm²
Wire connection cross section AWG, min.
AWG 26
Wire connection cross section AWG, max.
AWG 12
ETIM 6.0
EC002653
ETIM 7.0
EC002653
ETIM 8.0
EC002653
ETIM 9.0
EC002653
ECLASS 9.0
27-21-01-20
ECLASS 9.1
27-21-01-20
ECLASS 10.0
27-21-01-20
ECLASS 11.0
27-21-01-20
ECLASS 12.0
27-21-01-20
ECLASS 13.0
27-21-01-20
Long specification
Ex isolating switch amplifiers for Namur sensors 1-channel isolating switch amplifiers in 22.5 mm width with an external power supply, to transmit and isolate Namur sensor signals from Ex zones 0,1,2 into the safe zone. On the output side there is a potential-free relay contact with closing function and an alarm contact for status/error messages. The component can be configured using standard FDT/DTM software.
Add-on housing for TS35 DIN rail installation Dimensions: L/W/H 119.2/ 22.5/ 113.6 Screw connection/ nominal cross-section 2.5 mm2 Protection degree: IP20 Input NAMUR sensor according to EN 60947 8 VDC / 8 mA sensor power supply 0 to 5 kHz input frequency wire-break detection Output Relay 1 NO contact 250 VAC / 30 VDC @ 2A safe zone 32 VAC @ 0.5 A/ 32 VDC @ 1 A zone 2 Alarm output relay 1 NO contact 250 VAC / 30 VDC @ 2A safe zone 32 VAC @ 0.5 A/ 32 VDC @ 1 A zone 2Auxiliary power 19 to 31.2 VDC Power loss approx. 1.8 W Ambient temperature range -20 °C to +60 °C
Secure isolation EN 61010, 3-way isolation up to 2.6 kV AC/DC of all circuits against each other Working voltage 300 V AC/DC at overvoltage category II and pollution degree 2 Approvals cULus, ATEX IECEX, FM ATEX marking II 3 G ExnA nC IIC T4 ATEX characteristic data U0 = 10, 6 V DC I0 = 12 mA DC P0 = 32 W Type ACT20X-HDI-SDO-RNO-S
Short specification
Ex isolating switch amplifiers for Namur sensors 1-channel isolating switch amplifiers in 22.5 mm width with an external power supply, to transmit and isolate Namur sensor signals from Ex zones 0,1,2 into the safe zone. On the output side there is a potential-free relay contact with closing function and an alarm contact for status/error messages. The component can be configured using standard FDT/DTM software.
Approvals
Approvals
DNVGL;
ROHS
Conform
UL File Number Search
UL Website
Certificate no. (cULus)
E337701
Type of connection:
Screw connection
Order No.:
8965350000
Type:
ACT20X-HDI-SDO-RNC-S
Version:
EX signal isolating converter, Ex-input: NAMUR sensor/switch, Safe-output: relay, NC contact, 1-channel
Type of connection:
PUSH IN
Order No.:
2456060000
Type:
ACT20X-HDI-SDO-RNC-P
Version:
EX signal isolating converter, Ex-input: NAMUR sensor/switch, Safe-output: relay, NC contact, 1-channel
Type of connection:
PUSH IN
Order No.:
2456050000
Type:
ACT20X-HDI-SDO-RNO-P
Version:
EX signal isolating converter, Ex-input: NAMUR sensor/switch, Safe-output: relay, NO contact, 1-channel
Type of connection:
Screw connection
Order No.:
8965380000
Type:
ACT20X-2HDI-2SDO-RNC-S
Version:
EX signal isolating converter, Ex-input: NAMUR sensor/switch, Safe-output: relay, NC contact, 2-channel
Type of connection:
PUSH IN
Order No.:
2456090000
Type:
ACT20X-2HDI-2SDO-RNC-P
Version:
EX signal isolating converter, Ex-input: NAMUR sensor/switch, Safe-output: relay, NC contact, 2-channel
Type of connection:
Screw connection
Order No.:
8965370000
Type:
ACT20X-2HDI-2SDO-RNO-S
Version:
EX signal isolating converter, Ex-input: NAMUR sensor/switch, Safe-output: relay, NO contact, 2-channel
Type of connection:
PUSH IN
Order No.:
2456080000
Type:
ACT20X-2HDI-2SDO-RNO-P
Version:
EX signal isolating converter, Ex-input: NAMUR sensor/switch, Safe-output: relay, NO contact, 2-channel
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.