Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Analogue Signal Conditioning
Power Supplies
Electronics Housings
Lightning and Surge Protection
Photovoltaics
e-mobility
Fieldbus Distributors
SPDs for energy systems
SPDs for instrumentation and control (I&C)
SPDs for data interfaces
Accessories
pluggable VSPC series
non-pluggable VSSC series in terminal design
non-pluggable MCZovp series with tension-clamp connection
Cable Gland VCG series
Pluggable arresters for VSPC
Base elements for VSPC
Supply and alert unit for VSPC R arresters
Accessories for the VSPC series
2-level protection for analogue and binary signals
Combi-module protects 24V supply voltage and a current loop
Surge protection for Uk0 /S0 interfaces (telecomm.)
Surge protection for data signals
Surge protection with components such as varistors, gas arresters or suppressor diodes
Surge protection for binary signals and EX ia signals
Surge protection for current loops and EX ia signals
Three-wire and four-wire measuring bridges
Binary signals with signal contact
Binary signals without alert contact, also for EX ia applications
General ordering data
Version
Surge protection for instrumentation and control, with warning function / function indicator, UP (L/N-PE) <200 V
Order No.
8951630000
Type
VSPC 2SL 24VDC R
GTIN (EAN)
4032248742875
Qty.
1 pc(s).
Dimensions and weights
Depth
69 mm
Depth (inches)
2.717 inch
Height
98 mm
Height (inches)
3.858 inch
Width
17.8 mm
Width (inches)
0.701 inch
Net weight
45 g
Temperatures
Storage temperature
-40 °C...80 °C
Operating temperature
-40 °C...70 °C
Humidity
5...96 %
Probability of failure
SIL in compliance with IEC 61508
2
MTTF
2,665 a
SFF
86.02 %
λges
43
PFH in 1*10-9 per hour
10.7
Environmental Product Compliance
REACH SVHC
Lead 7439-92-1
SCIP
71e97bb7-979f-4330-94c0-20c629bb05e3
RoHS Compliance Status
Compliant with exemption
RoHS Exemption (if applicable/known)
7a, 7cI
CSA protection data
Gas group C
IIB
Gas group D
IIA
Gas groups A, B
IIC
Input voltage, max. Ui
28 V
Internal capacity, max. CI
2 nF
Internal inductance, max. LI
0 µH
General data
Colour
orange
Design
Terminal, miscellaneous
Optical function display
green = OK; red = arrester is defective - replace
Protection degree
IP20
Segment
Measurement - Monitoring - Setting
UL 94 flammability rating
V-0
Version
with warning function / function indicator
protected binary signals
2
Insulation coordination acc. to EN 50178
Pollution severity
2
Surge voltage category
III
Rated data IEC / EN
Discharge current Imax (8/20µs) GND-PE
10 kA
Discharge current Imax (8/20µs) wire-PE
10 kA
Discharge current Imax (8/20µs) wire-wire
10 kA
Discharge current In (8/20µs) GND-PE
2.5 kA
Discharge current In (8/20µs) wire-PE
2.5 kA
Discharge current In (8/20µs) wire-wire
2.5 kA
Fuse
0.5 A
Lightning test current, Iimp (10/350 µs) GND-PE
2.5 kA
Lightning test current, Iimp (10/350 µs) Wire-PE
2.5 kA
Lightning test current, Iimp (10/350 µs) wire-wire
2.5 kA
Max. continuous voltage, Uc (DC)
28 V
Number of poles
1
Overload - failure mode
Modus 2
Protection level UP (typ.)
<200 V
Protection level on output side Wire-PE 1kV/µs, typically
40 V
Protection level on output side Wire-wire 1 kV/µs, typically
80 V
Protection level on output side Wire-wire 8/20 µs, typically
80 V
Protection level, UP GND - PE
450 V
Protection level, UP wire - PE
40 V
Pulse-reset capacity
≤ 30 ms
Rated current IN
300 mA
Rated voltage (DC)
24 V
Requirements category acc. to IEC 61643-21
C1, C2, C3, D1
Signal transmission properties (-3 dB)
2.7 MHz
Signalling contact
UN 250 V AC 0.1 A 1CO at VSPC R with VSPC control unit
Standards
IEC 61643-21
Surge current-carrying capacity C1
<1 kA 8/20 μs
Surge current-carrying capacity C2
5 kA 8/20 μs
Surge current-carrying capacity C3
100 A 10/1000 μs
Surge current-carrying capacity D1
2.5 kA 10/350 μs
Voltage type
DC
Volume resistance
4.7 Ω
Connection data
Type of connection
Pluggable in VSPC BASE
Guarantee
Time interval
5 years
Important note
Product information
Mode 2: State where the voltage-limiting part of the SPD was short-circuited due to a very low impedance within the SPD. The line is inoperable, but the measuring equipment is still protected by means of a short-circuit.
Classifications
ETIM 6.0
EC000943
ETIM 7.0
EC000943
ETIM 8.0
EC000943
ETIM 9.0
EC000943
ECLASS 9.0
27-13-08-07
ECLASS 9.1
27-13-08-07
ECLASS 10.0
27-13-08-07
ECLASS 11.0
27-13-08-07
ECLASS 12.0
27-17-90-90
ECLASS 13.0
27-17-90-90
ECLASS 14.0
27-17-90-90
Tender specification sheets
Long specification
Surge protection plug for use in connection with the base element VSPC BASE 2SL R for two wires with a common ground and with integrated status display and remote monitoring option. Two-stage protection circuit in the plug consisting of coarse protection, decoupling resistors and fine protection between the signal wires and the signal ground/ground/earth. Mechanical identification of the plug to the base element according to the switching type and rated voltage. Protected plug with coding pin and counter-profile for the base element. Optical identification of the protected plug based on the type of protected switching and the voltage level. It is possible to mark the plug.
Short specification
Surge protection plug for base element VSPC BASE 2SL R, with integrated status display and remote monitoring option. Coarse and fine common mode voltage protection for two wires with a common ground. Version: 24 V DC
Type of connection:
Pluggable in VSPC BASE
Order No.:
8951620000
Type:
VSPC 2SL 12VDC R
Version:
Surge protection for instrumentation and control, with warning function / function indicator, UP (L/N-PE) <200 V
Type of connection:
Pluggable in VSPC BASE
Order No.:
8951640000
Type:
VSPC 2SL 24VAC R
Version:
Surge protection for instrumentation and control, with warning function / function indicator, UP (L/N-PE) 250 V
Type of connection:
Pluggable in VSPC BASE
Order No.:
8951610000
Type:
VSPC 2SL 5VDC R
Version:
Surge protection for instrumentation and control, with warning function / function indicator, UP (L/N-PE) <200 V
Type of connection:
Pluggable in VSPC BASE
Order No.:
8951580000
Type:
VSPC 4SL 12VDC R
Version:
Surge protection for instrumentation and control, with warning function / function indicator, UP (L/N-PE) <200 V
Type of connection:
Pluggable in VSPC BASE
Order No.:
8951600000
Type:
VSPC 4SL 24VAC R
Version:
Surge protection for instrumentation and control, with warning function / function indicator, UP (L/N-PE) 250 V
Type of connection:
Pluggable in VSPC BASE
Order No.:
8951590000
Type:
VSPC 4SL 24VDC R
Version:
Surge protection for instrumentation and control, with warning function / function indicator, UP (L/N-PE) <200 V
Type of connection:
Pluggable in VSPC BASE
Order No.:
8951570000
Type:
VSPC 4SL 5VDC R
Version:
Surge protection for instrumentation and control, with warning function / function indicator, UP (L/N-PE) <200 V
Version
Surge protection for instrumentation and control, with warning function / function indicator, UP (L/N-PE) <200 V
Order No.
8951630000
Type
VSPC 2SL 24VDC R
GTIN (EAN)
4032248742875
Qty.
1 pc(s).
Depth
69 mm
Depth (inches)
2.717 inch
Height
98 mm
Height (inches)
3.858 inch
Width
17.8 mm
Width (inches)
0.701 inch
Net weight
45 g
Storage temperature
-40 °C...80 °C
Operating temperature
-40 °C...70 °C
Humidity
5...96 %
SIL in compliance with IEC 61508
2
MTTF
2,665 a
SFF
86.02 %
λges
43
PFH in 1*10-9 per hour
10.7
REACH SVHC
Lead 7439-92-1
SCIP
71e97bb7-979f-4330-94c0-20c629bb05e3
RoHS Compliance Status
Compliant with exemption
RoHS Exemption (if applicable/known)
7a, 7cI
Gas group C
IIB
Gas group D
IIA
Gas groups A, B
IIC
Input voltage, max. Ui
28 V
Internal capacity, max. CI
2 nF
Internal inductance, max. LI
0 µH
Colour
orange
Design
Terminal, miscellaneous
Optical function display
green = OK; red = arrester is defective - replace
Protection degree
IP20
Segment
Measurement - Monitoring - Setting
UL 94 flammability rating
V-0
Version
with warning function / function indicator
protected binary signals
2
Pollution severity
2
Surge voltage category
III
Discharge current Imax (8/20µs) GND-PE
10 kA
Discharge current Imax (8/20µs) wire-PE
10 kA
Discharge current Imax (8/20µs) wire-wire
10 kA
Discharge current In (8/20µs) GND-PE
2.5 kA
Discharge current In (8/20µs) wire-PE
2.5 kA
Discharge current In (8/20µs) wire-wire
2.5 kA
Fuse
0.5 A
Lightning test current, Iimp (10/350 µs) GND-PE
2.5 kA
Lightning test current, Iimp (10/350 µs) Wire-PE
2.5 kA
Lightning test current, Iimp (10/350 µs) wire-wire
2.5 kA
Max. continuous voltage, Uc (DC)
28 V
Number of poles
1
Overload - failure mode
Modus 2
Protection level UP (typ.)
<200 V
Protection level on output side Wire-PE 1kV/µs, typically
40 V
Protection level on output side Wire-wire 1 kV/µs, typically
80 V
Protection level on output side Wire-wire 8/20 µs, typically
80 V
Protection level, UP GND - PE
450 V
Protection level, UP wire - PE
40 V
Pulse-reset capacity
≤ 30 ms
Rated current IN
300 mA
Rated voltage (DC)
24 V
Requirements category acc. to IEC 61643-21
C1, C2, C3, D1
Signal transmission properties (-3 dB)
2.7 MHz
Signalling contact
UN 250 V AC 0.1 A 1CO at VSPC R with VSPC control unit
Standards
IEC 61643-21
Surge current-carrying capacity C1
<1 kA 8/20 μs
Surge current-carrying capacity C2
5 kA 8/20 μs
Surge current-carrying capacity C3
100 A 10/1000 μs
Surge current-carrying capacity D1
2.5 kA 10/350 μs
Voltage type
DC
Volume resistance
4.7 Ω
Type of connection
Pluggable in VSPC BASE
Product information
Mode 2: State where the voltage-limiting part of the SPD was short-circuited due to a very low impedance within the SPD. The line is inoperable, but the measuring equipment is still protected by means of a short-circuit.
ETIM 6.0
EC000943
ETIM 7.0
EC000943
ETIM 8.0
EC000943
ETIM 9.0
EC000943
ECLASS 9.0
27-13-08-07
ECLASS 9.1
27-13-08-07
ECLASS 10.0
27-13-08-07
ECLASS 11.0
27-13-08-07
ECLASS 12.0
27-17-90-90
ECLASS 13.0
27-17-90-90
ECLASS 14.0
27-17-90-90
Long specification
Surge protection plug for use in connection with the base element VSPC BASE 2SL R for two wires with a common ground and with integrated status display and remote monitoring option. Two-stage protection circuit in the plug consisting of coarse protection, decoupling resistors and fine protection between the signal wires and the signal ground/ground/earth. Mechanical identification of the plug to the base element according to the switching type and rated voltage. Protected plug with coding pin and counter-profile for the base element. Optical identification of the protected plug based on the type of protected switching and the voltage level. It is possible to mark the plug.
Short specification
Surge protection plug for base element VSPC BASE 2SL R, with integrated status display and remote monitoring option. Coarse and fine common mode voltage protection for two wires with a common ground. Version: 24 V DC
Approvals
ROHS
Conform
UL File Number Search
UL Website
Certificate No. (UL)
E311081
Type of connection:
Pluggable in VSPC BASE
Order No.:
8951620000
Type:
VSPC 2SL 12VDC R
Version:
Surge protection for instrumentation and control, with warning function / function indicator, UP (L/N-PE) <200 V
Type of connection:
Pluggable in VSPC BASE
Order No.:
8951640000
Type:
VSPC 2SL 24VAC R
Version:
Surge protection for instrumentation and control, with warning function / function indicator, UP (L/N-PE) 250 V
Type of connection:
Pluggable in VSPC BASE
Order No.:
8951610000
Type:
VSPC 2SL 5VDC R
Version:
Surge protection for instrumentation and control, with warning function / function indicator, UP (L/N-PE) <200 V
Type of connection:
Pluggable in VSPC BASE
Order No.:
8951580000
Type:
VSPC 4SL 12VDC R
Version:
Surge protection for instrumentation and control, with warning function / function indicator, UP (L/N-PE) <200 V
Type of connection:
Pluggable in VSPC BASE
Order No.:
8951600000
Type:
VSPC 4SL 24VAC R
Version:
Surge protection for instrumentation and control, with warning function / function indicator, UP (L/N-PE) 250 V
Type of connection:
Pluggable in VSPC BASE
Order No.:
8951590000
Type:
VSPC 4SL 24VDC R
Version:
Surge protection for instrumentation and control, with warning function / function indicator, UP (L/N-PE) <200 V
Type of connection:
Pluggable in VSPC BASE
Order No.:
8951570000
Type:
VSPC 4SL 5VDC R
Version:
Surge protection for instrumentation and control, with warning function / function indicator, UP (L/N-PE) <200 V
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.