Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Analogue Signal Conditioning
Power Supplies
Electronics Housings
Lightning and Surge Protection
e-mobility
Photovoltaics
Fieldbus Distributors
Network-compatible current measuring transducers ACT20C
intrinsically safe signal converter - ACT20X
signal converter and process monitoring - ACT20P
Space-saving signal converter - ACT20M
Signal converter in terminal block format - MCZ
Compact standard signal isolators - PicoPak
Process monitoring displays
Analogue-digital / digital-analogue converter
Signal - & serial interface converter– WAVESERIES
Configuration software
Accessories
Frequency signal converter
Limit-value monitoring
Passive isolator
Temperature transducer
Limit- & current monitoring
Logic modules
General ordering data
Version
Temperature converter, 2-/3-wire connection technology, Output current loop powered, Tension-clamp connection, Output : 4-20 mA
Order No.
8483680000
Type
MCZ PT100/3 CLP 0...120C
GTIN (EAN)
4032248157853
Qty.
10 pc(s).
Dimensions and weights
Depth
63.2 mm
Depth (inches)
2.488 inch
Width
6 mm
Width (inches)
0.236 inch
Length
91 mm
Length (inches)
3.583 inch
Net weight
29 g
Temperatures
Storage temperature
-25 °C...85 °C
Operating temperature
-25 °C...50 °C
Probability of failure
SIL in compliance with IEC 61508
None
MTTF
1,060 a
Environmental Product Compliance
RoHS Compliance Status
Compliant with exemption
RoHS Exemption (if applicable/known)
6c, 7a, 7cI
REACH SVHC
Lead 7439-92-1
SCIP
c2a21576-d875-4548-ae68-5e7f85ddf0c7
Input
Number of inputs
1
Sensor
PT100 (3 wire)
Sensor supply
0.8 mA / 9…30 V DC
Temperature input range
0...120 °C
Output
Load impedance current
≤ 600 Ω
Number of outputs
1
Output current
4...20 mA (current loop) at 9...30V DC
General data
Accuracy
Typ.: 0.2 %, máx. 0.5 % v. FSR
Configuration
none
Galvanic isolation
Without isolation
Linearity
Yes
Long-term drift
0
Protection degree
IP20
Rail
TS 35
Step response time
10 ms
Temperature coefficient
max. ± 250 ppm/K
Voltage supply
Output loop powered, max. 30 V/ min. 9 V + (20 mA x RL)
Insulation coordination
EMC standards
EN 61000-6
Galvanic isolation
Without isolation
Pollution severity
2
Rated voltage
50 V
Surge voltage category
I
Connection data
Type of connection
Tension-clamp connection
Clamping range, rated connection
1.5 mm²
Clamping range, min.
0.5 mm²
Clamping range, max.
1.5 mm²
Wire connection cross section AWG, min.
AWG 26
Wire connection cross section AWG, max.
AWG 16
Wire cross-section, solid, min.
0.5 mm²
Wire cross-section, solid, max.
1.5 mm²
Wire cross-section, solid, min. (AWG)
AWG 26
Wire cross-section, solid, max. (AWG)
AWG 16
Wire connection cross section, finely stranded, min.
0.5 mm²
Wire connection cross section, finely stranded, max.
1.5 mm²
Wire cross-section, finely stranded, min. (AWG)
AWG 26
Wire cross-section, finely stranded, max. (AWG)
AWG 16
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.
0.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.
1.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.
0.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.
1.5 mm²
Classifications
ETIM 6.0
EC002919
ETIM 7.0
EC002919
ETIM 8.0
EC002919
ETIM 9.0
EC002919
ECLASS 9.0
27-21-01-29
ECLASS 9.1
27-21-01-29
ECLASS 10.0
27-21-01-29
ECLASS 11.0
27-21-01-29
ECLASS 12.0
27-21-01-29
ECLASS 13.0
27-21-01-29
ECLASS 14.0
27-21-01-29
Tender specification sheets
Long specification
PT100 temperature measuring transformer, output-loop powered, 3-wire connection technology RTD measuring transformer in 6 mm width, 4...20 mA output-loop powered without electrical isolation, for transmitting PT100 2-/3-wire signals. Input temperature range 0...+120 °C.
Add-on housing for TS35 rail mounting Dimensions: L/W/H 91/ 6/ 63.2 mm Tension-clamp connection / Nominal cross-section 1.5 mm2 Protection degree: IP 20 Input PT100, 2-/3-wireOutput 4...20 mALoad resistance Transmission error Auxiliary power via 4...20 mA current loopAmbient temperature range 0°C...+50 °C< 0,2 % v. E. Isolation no electrical isolationApprovals cURus, CSA
TypeMCZ PT100/3 CLP 0...120C
Short specification
PT100 temperature measuring transformer, output-loop powered, 3-wire connection technology RTD measuring transformer in 6 mm width, 4...20 mA output-loop powered without electrical isolation, for transmitting PT100 2-/3-wire signals. Input temperature range 0...+120 °C.
Approvals
Approvals
ROHS
Conform
Type of connection:
Tension-clamp connection
Order No.:
8425720000
Type:
MCZ PT100/3 CLP 0...100C
Version:
Temperature converter, 2-/3-wire connection technology, Output current loop powered, Tension-clamp connection, Output : 4-20 mA
Type of connection:
Tension-clamp connection
Order No.:
8604420000
Type:
MCZ PT100/3 CLP 0...150C
Version:
Temperature converter, 2-/3-wire connection technology, Output current loop powered, Tension-clamp connection, Output : 4-20 mA
Type of connection:
Tension-clamp connection
Order No.:
8705990000
Type:
C030-03 MCZ RTD CLP
Version:
Temperature converter, 2-/3-wire connection technology, Output current loop powered, Tension-clamp connection, Output : 4-20 mA
Type of connection:
Tension-clamp connection
Order No.:
8473010000
Type:
MCZ PT100/3 CLP 0...200C
Version:
Temperature converter, 2-/3-wire connection technology, Output current loop powered, Tension-clamp connection, Output : 4-20 mA
Type of connection:
Tension-clamp connection
Order No.:
8473020000
Type:
MCZ PT100/3 CLP 0...300C
Version:
Temperature converter, 2-/3-wire connection technology, Output current loop powered, Tension-clamp connection, Output : 4-20 mA
Type of connection:
Tension-clamp connection
Order No.:
8604430000
Type:
MCZ PT100/3 CLP -40C...100C
Version:
Temperature converter, 2-/3-wire connection technology, Output current loop powered, Tension-clamp connection, Output : 4-20 mA
Type of connection:
Tension-clamp connection
Order No.:
8473000000
Type:
MCZ PT100/3 CLP -50C...+150C
Version:
Temperature converter, 2-/3-wire connection technology, Output current loop powered, Tension-clamp connection, Output : 4-20 mA
Version
Temperature converter, 2-/3-wire connection technology, Output current loop powered, Tension-clamp connection, Output : 4-20 mA
Order No.
8483680000
Type
MCZ PT100/3 CLP 0...120C
GTIN (EAN)
4032248157853
Qty.
10 pc(s).
Depth
63.2 mm
Depth (inches)
2.488 inch
Width
6 mm
Width (inches)
0.236 inch
Length
91 mm
Length (inches)
3.583 inch
Net weight
29 g
Storage temperature
-25 °C...85 °C
Operating temperature
-25 °C...50 °C
SIL in compliance with IEC 61508
None
MTTF
1,060 a
RoHS Compliance Status
Compliant with exemption
RoHS Exemption (if applicable/known)
6c, 7a, 7cI
REACH SVHC
Lead 7439-92-1
SCIP
c2a21576-d875-4548-ae68-5e7f85ddf0c7
Number of inputs
1
Sensor
PT100 (3 wire)
Sensor supply
0.8 mA / 9…30 V DC
Temperature input range
0...120 °C
Load impedance current
≤ 600 Ω
Number of outputs
1
Output current
4...20 mA (current loop) at 9...30V DC
Accuracy
Typ.: 0.2 %, máx. 0.5 % v. FSR
Configuration
none
Galvanic isolation
Without isolation
Linearity
Yes
Long-term drift
0
Protection degree
IP20
Rail
TS 35
Step response time
10 ms
Temperature coefficient
max. ± 250 ppm/K
Voltage supply
Output loop powered, max. 30 V/ min. 9 V + (20 mA x RL)
EMC standards
EN 61000-6
Galvanic isolation
Without isolation
Pollution severity
2
Rated voltage
50 V
Surge voltage category
I
Type of connection
Tension-clamp connection
Clamping range, rated connection
1.5 mm²
Clamping range, min.
0.5 mm²
Clamping range, max.
1.5 mm²
Wire connection cross section AWG, min.
AWG 26
Wire connection cross section AWG, max.
AWG 16
Wire cross-section, solid, min.
0.5 mm²
Wire cross-section, solid, max.
1.5 mm²
Wire cross-section, solid, min. (AWG)
AWG 26
Wire cross-section, solid, max. (AWG)
AWG 16
Wire connection cross section, finely stranded, min.
0.5 mm²
Wire connection cross section, finely stranded, max.
1.5 mm²
Wire cross-section, finely stranded, min. (AWG)
AWG 26
Wire cross-section, finely stranded, max. (AWG)
AWG 16
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.
0.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.
1.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.
0.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.
1.5 mm²
ETIM 6.0
EC002919
ETIM 7.0
EC002919
ETIM 8.0
EC002919
ETIM 9.0
EC002919
ECLASS 9.0
27-21-01-29
ECLASS 9.1
27-21-01-29
ECLASS 10.0
27-21-01-29
ECLASS 11.0
27-21-01-29
ECLASS 12.0
27-21-01-29
ECLASS 13.0
27-21-01-29
ECLASS 14.0
27-21-01-29
Long specification
PT100 temperature measuring transformer, output-loop powered, 3-wire connection technology RTD measuring transformer in 6 mm width, 4...20 mA output-loop powered without electrical isolation, for transmitting PT100 2-/3-wire signals. Input temperature range 0...+120 °C.
Add-on housing for TS35 rail mounting Dimensions: L/W/H 91/ 6/ 63.2 mm Tension-clamp connection / Nominal cross-section 1.5 mm2 Protection degree: IP 20 Input PT100, 2-/3-wireOutput 4...20 mALoad resistance Transmission error Auxiliary power via 4...20 mA current loopAmbient temperature range 0°C...+50 °C< 0,2 % v. E. Isolation no electrical isolationApprovals cURus, CSA
TypeMCZ PT100/3 CLP 0...120C
Short specification
PT100 temperature measuring transformer, output-loop powered, 3-wire connection technology RTD measuring transformer in 6 mm width, 4...20 mA output-loop powered without electrical isolation, for transmitting PT100 2-/3-wire signals. Input temperature range 0...+120 °C.
Approvals
ROHS
Conform
Type of connection:
Tension-clamp connection
Order No.:
8425720000
Type:
MCZ PT100/3 CLP 0...100C
Version:
Temperature converter, 2-/3-wire connection technology, Output current loop powered, Tension-clamp connection, Output : 4-20 mA
Type of connection:
Tension-clamp connection
Order No.:
8604420000
Type:
MCZ PT100/3 CLP 0...150C
Version:
Temperature converter, 2-/3-wire connection technology, Output current loop powered, Tension-clamp connection, Output : 4-20 mA
Type of connection:
Tension-clamp connection
Order No.:
8705990000
Type:
C030-03 MCZ RTD CLP
Version:
Temperature converter, 2-/3-wire connection technology, Output current loop powered, Tension-clamp connection, Output : 4-20 mA
Type of connection:
Tension-clamp connection
Order No.:
8473010000
Type:
MCZ PT100/3 CLP 0...200C
Version:
Temperature converter, 2-/3-wire connection technology, Output current loop powered, Tension-clamp connection, Output : 4-20 mA
Type of connection:
Tension-clamp connection
Order No.:
8473020000
Type:
MCZ PT100/3 CLP 0...300C
Version:
Temperature converter, 2-/3-wire connection technology, Output current loop powered, Tension-clamp connection, Output : 4-20 mA
Type of connection:
Tension-clamp connection
Order No.:
8604430000
Type:
MCZ PT100/3 CLP -40C...100C
Version:
Temperature converter, 2-/3-wire connection technology, Output current loop powered, Tension-clamp connection, Output : 4-20 mA
Type of connection:
Tension-clamp connection
Order No.:
8473000000
Type:
MCZ PT100/3 CLP -50C...+150C
Version:
Temperature converter, 2-/3-wire connection technology, Output current loop powered, Tension-clamp connection, Output : 4-20 mA
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.