Product wizard 
 Website 
English
Deutsch
Français
Italiano
Japanese
Español
Svenska
Россия
繁體中文
简体中文
Polska
한국어
Čeština
Magyar
  
0
0
Quick access
MCZ PT100/3 CLP 0...200C
         

Icon
Icon
Icon
Icon
Icon
 

General ordering data

Version Temperature converter, 2-/3-wire connection technology, Output current loop powered, Tension-clamp connection, Output : 4-20 mA
Order No. 8473010000
Type MCZ PT100/3 CLP 0...200C
GTIN (EAN) 4032248058280
Qty. 10 pc(s).

Dimensions and weights

Depth 63.2 mm
Depth (inches) 2.488 inch
Width 6 mm
Width (inches) 0.236 inch
Length 91 mm
Length (inches) 3.583 inch
Net weight 26.4 g

Temperatures

Storage temperature -25 °C...85 °C
Operating temperature -25 °C...50 °C

Probability of failure

SIL in compliance with IEC 61508 None
MTTF 1,068 a

Environmental Product Compliance

RoHS Compliance Status Compliant with exemption
RoHS Exemption (if applicable/known) 6c, 7a, 7cI
REACH SVHC Lead 7439-92-1
SCIP c2a21576-d875-4548-ae68-5e7f85ddf0c7

Input

Number of inputs 1
Sensor PT100 (3 wire)
Sensor supply 0.8 mA / 9…30 V DC
Temperature input range 0...200 °C

Output

Load impedance current ≤ 600 Ω
Number of outputs 1
Output current 4...20 mA (current loop) at 9...30V DC

General data

Accuracy Typ.: 0.2 %, máx. 0.5 % v. FSR
Configuration none
Galvanic isolation Without isolation
Linearity Yes
Long-term drift 0
Protection degree IP20
Rail TS 35
Step response time 10 ms
Temperature coefficient max. ± 250 ppm/K
Voltage supply Output loop powered, max. 30 V/ min. 9 V + (20 mA x RL)

Insulation coordination

EMC standards EN 61000-6
Galvanic isolation Without isolation
Pollution severity 2
Rated voltage 50 V
Surge voltage category I

Connection data

Type of connection Tension-clamp connection
Clamping range, rated connection 1.5 mm²
Clamping range, min. 0.5 mm²
Clamping range, max. 1.5 mm²
Wire connection cross section AWG, min. AWG 26
Wire connection cross section AWG, max. AWG 16
Wire cross-section, solid, min. 0.5 mm²
Wire cross-section, solid, max. 1.5 mm²
Wire cross-section, solid, min. (AWG) AWG 26
Wire cross-section, solid, max. (AWG) AWG 16
Wire connection cross section, finely stranded, min. 0.5 mm²
Wire connection cross section, finely stranded, max. 1.5 mm²
Wire cross-section, finely stranded, min. (AWG) AWG 26
Wire cross-section, finely stranded, max. (AWG) AWG 16
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min. 0.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max. 1.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min. 0.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max. 1.5 mm²

Downloads

Approval/Certificate/Document of Conformity
Engineering Data
Eplan Data Portal Eplan data
CADENAS eCATALOG CAX data
User Documentation
Catalogues Catalogues in PDF-format
Brochures

Classifications

ETIM 6.0 EC002919
ETIM 7.0 EC002919
ETIM 8.0 EC002919
ETIM 9.0 EC002919
ECLASS 9.0 27-21-01-29
ECLASS 9.1 27-21-01-29
ECLASS 10.0 27-21-01-29
ECLASS 11.0 27-21-01-29
ECLASS 12.0 27-21-01-29
ECLASS 13.0 27-21-01-29
ECLASS 14.0 27-21-01-29

Tender specification sheets

Long specification

PT100 temperature measuring transformer, output-loop powered,
3-wire connection technology
RTD measuring transformer in 6 mm width, 4...20 mA output-loop powered
without electrical isolation, for transmitting PT100 2-/3-wire signals.
Input temperature range 0...+200 °C.

Add-on housing for TS35 rail mounting
Dimensions: L/W/H 91/ 6/ 63.2 mm
Tension-clamp connection / Nominal cross-section 1.5 mm2
Protection degree: IP 20
Input PT100, 2-/3-wireOutput 4...20 mALoad resistance Transmission error Auxiliary power via 4...20 mA current loopAmbient temperature range 0°C...+50 °C< 0,2 % v. E.
Isolation no electrical isolationApprovals cURus, CSA





TypeMCZ PT100/3 CLP 0...200C

Short specification

PT100 temperature measuring transformer, output-loop powered,
3-wire connection technology
RTD measuring transformer in 6 mm width, 4...20 mA output-loop powered
without electrical isolation, for transmitting PT100 2-/3-wire signals.
Input temperature range 0...+200 °C.

Approvals

Approvals CE CSA CURUS
ROHS Conform
UL File Number Search UL Website
Certificate No. (cURus) E141197

Related products

Type of connection: Tension-clamp connection
Order No.: 8425720000
Type: MCZ PT100/3 CLP 0...100C
Version:
Temperature converter, 2-/3-wire connection technology, Output current loop powered, Tension-clamp connection, Output : 4-20 mA
 
Type of connection: Tension-clamp connection
Order No.: 8483680000
Type: MCZ PT100/3 CLP 0...120C
Version:
Temperature converter, 2-/3-wire connection technology, Output current loop powered, Tension-clamp connection, Output : 4-20 mA
 
Type of connection: Tension-clamp connection
Order No.: 8604420000
Type: MCZ PT100/3 CLP 0...150C
Version:
Temperature converter, 2-/3-wire connection technology, Output current loop powered, Tension-clamp connection, Output : 4-20 mA
 
Type of connection: Tension-clamp connection
Order No.: 8705990000
Type: C030-03 MCZ RTD CLP
Version:
Temperature converter, 2-/3-wire connection technology, Output current loop powered, Tension-clamp connection, Output : 4-20 mA
 
Type of connection: Tension-clamp connection
Order No.: 8473020000
Type: MCZ PT100/3 CLP 0...300C
Version:
Temperature converter, 2-/3-wire connection technology, Output current loop powered, Tension-clamp connection, Output : 4-20 mA
 
Type of connection: Tension-clamp connection
Order No.: 8604430000
Type: MCZ PT100/3 CLP -40C...100C
Version:
Temperature converter, 2-/3-wire connection technology, Output current loop powered, Tension-clamp connection, Output : 4-20 mA
 
Type of connection: Tension-clamp connection
Order No.: 8473000000
Type: MCZ PT100/3 CLP -50C...+150C
Version:
Temperature converter, 2-/3-wire connection technology, Output current loop powered, Tension-clamp connection, Output : 4-20 mA
 
Contact
Weidmüller Interface GmbH & Co. KG
 
+49 5231 14-0
+49 5231 14-292083
More information
Decentralised automation solutions
Energy Management Solutions
Industrial Analytics
Industrial IoT Solutions
More information
Mobility Concepts
Photovoltaics
Wind Solutions
Workplace Solutions
More information
Single Pair Ethernet
Weidmüller Configurator
Support & Service
Contact
Disposal Instructions
Engineering data
Repairs and replacement parts