Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Analogue Signal Conditioning
Power Supplies
Electronics Housings
Lightning and Surge Protection
Photovoltaics
e-mobility
Fieldbus Distributors
Network-compatible current measuring transducers ACT20C
intrinsically safe signal converter - ACT20X
signal converter and process monitoring - ACT20P
Space-saving signal converter - ACT20M
Signal converter in terminal block format - MCZ
Compact standard signal isolators - PicoPak
Process monitoring displays
Analogue-digital / digital-analogue converter
Signal - & serial interface converter– WAVESERIES
Configuration software
Accessories
Universal signal converter
Current measuring transducer
Frequency signal converter
Limit- & current monitoring
Serial interface converter
Temperature transducer
Signal converter
Rectifier modules
WAZ4 VVC DC 0-10/0-10V
Do not use product for new developmentsOnly remaining stock available
General ordering data
Version
Signal converter/insulator, Input : 0-10 V, Output : 0-10 V
Order No.
8447140000
Type
WAZ4 VVC DC 0-10/0-10V
GTIN (EAN)
4032248108084
Qty.
1 pc(s).
Delivery status
This article will no longer be available in the future.
Available until
2022-04-30
Dimensions and weights
Depth
112.4 mm
Depth (inches)
4.425 inch
Width
12.5 mm
Width (inches)
0.492 inch
Length
92.4 mm
Length (inches)
3.638 inch
Net weight
114 g
Temperatures
Storage temperature
-20 °C...85 °C
Operating temperature
0 °C...70 °C
Humidity at operating temperature
0...95 % (no condensation)
Humidity
40 °C / 93 % rel. humidity, no condensation
Probability of failure
SIL in compliance with IEC 61508
None
MTTF
597 a
Environmental Product Compliance
REACH SVHC
Lead 7439-92-1
SCIP
94561991-a963-4084-a5f3-dfa3a5c2a27e
RoHS Compliance Status
Compliant with exemption
RoHS Exemption (if applicable/known)
7a, 7cI
Input
Input resistance, voltage
500 kΩ
Input voltage
0...10 V
Number of inputs
1
Output
Cut-off frequency (-3 dB)
≥ 13 Hz (typ. 17 Hz)
Load impedance current
≤ 600 Ω
Number of outputs
1
Output voltage, note
0...10 V
load impedance voltage
≥ 1 kΩ
Output (digital)
Max. switching voltage, AC
0 V
Rated switching current
0.1 A
Output (analogue)
Load resistance voltage
≥ 1 kΩ
Output voltage
0...10 V
General data
Accuracy
± 0.2 % of final value
Current consumption
<11 mA @ UUT = 10 V
Galvanic isolation
2-way isolator
Protection degree
IP20
Rail
TS 35
Step response time
≤ 30 ms (typ. 25 ms)
Temperature coefficient
≤ 250 ppm/K of final value
Voltage supply
24 V DC ± 20 %
Insulation coordination
EMC standards
EN 55011, EN 61000-6
Galvanic isolation
2-way isolator
Impulse withstand voltage
4 kV
Insulation voltage
1.2 kVeff / 5 s
Insulation voltage input or output/rail
4 kVeff / 1 min.
Insulation voltage input or output/supply
4 kVeff / 1 min.
Pollution severity
2
Rated voltage
300 V
Surge voltage category
III
Connection data
Type of connection
Tension-clamp connection
Stripping length, rated connection
7 mm
Clamping range, rated connection
1.5 mm²
Clamping range, min.
0.5 mm²
Clamping range, max.
2.5 mm²
Important note
Product information
This product will soon be replaced by a new product. Please do not use with new systems. Please contact our technical support.
Classifications
ETIM 6.0
EC002653
ETIM 7.0
EC002653
ETIM 8.0
EC002653
ETIM 9.0
EC002653
ECLASS 9.0
27-21-01-20
ECLASS 9.1
27-21-01-20
ECLASS 10.0
27-21-01-20
ECLASS 11.0
27-21-01-20
ECLASS 12.0
27-21-01-20
ECLASS 13.0
27-21-01-20
ECLASS 14.0
27-21-01-20
Order No.:
8445050000
Type of connection:
Tension-clamp connection
Type:
WAZ4 CVC DC 4-20/0-10V
Version:
Signal converter/insulator, Input : 4-20 mA, Output : 0-10 V
Delivery status:
This article will no longer be available in the future.
Order No.:
8540300000
Type of connection:
Tension-clamp connection
Type:
WAZ5 VCC 0-10V/4-20MA
Version:
Signal converter/insulator, Input : 0-10 V, Output : 4-20 mA
Delivery status:
This article will no longer be available in the future.
Order No.:
8540340000
Type of connection:
Tension-clamp connection
Type:
WAZ5 VVC 0-10V/0-10V
Version:
Signal converter/insulator, Input : 0-10 V, Output : 0-10 V
Delivery status:
This article will no longer be available in the future.
Version
Signal converter/insulator, Input : 0-10 V, Output : 0-10 V
Order No.
8447140000
Type
WAZ4 VVC DC 0-10/0-10V
GTIN (EAN)
4032248108084
Qty.
1 pc(s).
Delivery status
This article will no longer be available in the future.
Available until
2022-04-30
Depth
112.4 mm
Depth (inches)
4.425 inch
Width
12.5 mm
Width (inches)
0.492 inch
Length
92.4 mm
Length (inches)
3.638 inch
Net weight
114 g
Storage temperature
-20 °C...85 °C
Operating temperature
0 °C...70 °C
Humidity at operating temperature
0...95 % (no condensation)
Humidity
40 °C / 93 % rel. humidity, no condensation
SIL in compliance with IEC 61508
None
MTTF
597 a
REACH SVHC
Lead 7439-92-1
SCIP
94561991-a963-4084-a5f3-dfa3a5c2a27e
RoHS Compliance Status
Compliant with exemption
RoHS Exemption (if applicable/known)
7a, 7cI
Input resistance, voltage
500 kΩ
Input voltage
0...10 V
Number of inputs
1
Cut-off frequency (-3 dB)
≥ 13 Hz (typ. 17 Hz)
Load impedance current
≤ 600 Ω
Number of outputs
1
Output voltage, note
0...10 V
load impedance voltage
≥ 1 kΩ
Max. switching voltage, AC
0 V
Rated switching current
0.1 A
Load resistance voltage
≥ 1 kΩ
Output voltage
0...10 V
Accuracy
± 0.2 % of final value
Current consumption
<11 mA @ UUT = 10 V
Galvanic isolation
2-way isolator
Protection degree
IP20
Rail
TS 35
Step response time
≤ 30 ms (typ. 25 ms)
Temperature coefficient
≤ 250 ppm/K of final value
Voltage supply
24 V DC ± 20 %
EMC standards
EN 55011, EN 61000-6
Galvanic isolation
2-way isolator
Impulse withstand voltage
4 kV
Insulation voltage
1.2 kVeff / 5 s
Insulation voltage input or output/rail
4 kVeff / 1 min.
Insulation voltage input or output/supply
4 kVeff / 1 min.
Pollution severity
2
Rated voltage
300 V
Surge voltage category
III
Type of connection
Tension-clamp connection
Stripping length, rated connection
7 mm
Clamping range, rated connection
1.5 mm²
Clamping range, min.
0.5 mm²
Clamping range, max.
2.5 mm²
Product information
This product will soon be replaced by a new product. Please do not use with new systems. Please contact our technical support.
ETIM 6.0
EC002653
ETIM 7.0
EC002653
ETIM 8.0
EC002653
ETIM 9.0
EC002653
ECLASS 9.0
27-21-01-20
ECLASS 9.1
27-21-01-20
ECLASS 10.0
27-21-01-20
ECLASS 11.0
27-21-01-20
ECLASS 12.0
27-21-01-20
ECLASS 13.0
27-21-01-20
ECLASS 14.0
27-21-01-20
Approvals
ROHS
Conform
UL File Number Search
UL Website
Certificate no. (cULus)
E141197
Order No.:
8445050000
Type of connection:
Tension-clamp connection
Type:
WAZ4 CVC DC 4-20/0-10V
Version:
Signal converter/insulator, Input : 4-20 mA, Output : 0-10 V
Delivery status:
This article will no longer be available in the future.
Order No.:
8540300000
Type of connection:
Tension-clamp connection
Type:
WAZ5 VCC 0-10V/4-20MA
Version:
Signal converter/insulator, Input : 0-10 V, Output : 4-20 mA
Delivery status:
This article will no longer be available in the future.
Order No.:
8540340000
Type of connection:
Tension-clamp connection
Type:
WAZ5 VVC 0-10V/0-10V
Version:
Signal converter/insulator, Input : 0-10 V, Output : 0-10 V
Delivery status:
This article will no longer be available in the future.
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.