Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Analogue Signal Conditioning
Power Supplies
Electronics Housings
Lightning and Surge Protection
e-mobility
Photovoltaics
Fieldbus Distributors
Network-compatible current measuring transducers ACT20C
intrinsically safe signal converter - ACT20X
signal converter and process monitoring - ACT20P
Space-saving signal converter - ACT20M
Signal converter in terminal block format - MCZ
Compact standard signal isolators - PicoPak
Process monitoring displays
Analogue-digital / digital-analogue converter
Signal - & serial interface converter– WAVESERIES
Configuration software
Accessories
Signal converters
Passive isolator
Signal splitter
Temperature transducer
Measuring and monitoring relay
Current measuring transducer
Bridge measuring transducer
Frequency converters
Universal
General ordering data
Version
Signal converter/insulator, Input : AC/DC voltage, 0...600 V DC, 0…440 V AC, Output : 0-10 V, 0(4)-20 mA, Signal converter/isolator
Order No.
7760054360
Type
ACT20P-VM-AO-P
GTIN (EAN)
4050118559743
Qty.
1 pc(s).
Dimensions and weights
Depth
114.3 mm
Depth (inches)
4.5 inch
Height
119.2 mm
Height (inches)
4.693 inch
Width
22.5 mm
Width (inches)
0.886 inch
Net weight
140 g
Temperatures
Storage temperature
-40 °C...85 °C
Operating temperature
-20 °C...60 °C
Humidity at operating temperature
0...95 % (no condensation)
Humidity
5...95 %, no condensation
Probability of failure
SIL in compliance with IEC 61508
None
MTTF
140 a
Environmental Product Compliance
REACH SVHC
Lead 7439-92-1
SCIP
2f6dd957-421a-46db-a0c2-cf1609156924
Input
Input resistance
1 MΩ±5%
Input voltage
0…30 V DC, 0…60 V DC, 0…300 V DC, 0…440 V DC, 0…660 V DC, 0…60 V AC, 0…144 V AC, 0…300 V AC, 0…440 V AC
Number of inputs
1
Output
Load impedance current
≤ 500 Ω
Number of outputs
1
Output current
0...20 mA, 4...20 mA
Output voltage, note
0...10 V
Type
active, connected control must be passive
load impedance voltage
≥ 10 kΩ
General data
Accuracy
0.5 % FSR
Configuration
With FDT/DTM software, Requires configuration adapter 8978580000 CBX200 USB
Galvanic isolation
between input ⁄ output ⁄ supply
Power consumption
≤ 100 mA @ 24 VDC, ≤ 120mA @ 24V AC
Protection degree
IP20
Rail
TS 35
Step response time
<300 ms
Temperature coefficient
≤ 200 ppm/K
Voltage supply
24…240 VUC (±10%)
Insulation coordination
EMC standards
EN 61326-1, EN 61000-6-2, EN 61000-6-4
Galvanic isolation
between input ⁄ output ⁄ supply
Impulse withstand voltage
4 kV (1.2/50 μs) input - output, 4 kV (1.2/50 μs) input / supply, 2.5 kV (1.2/50 μs) output / supply
Insulation voltage
1.5 kV AC output / supply, 2 kV AC input / output, 2 kV AC input / supply
Pollution severity
2
Rated voltage
600 V input / output, 600 V input / supply, 300 V output / supply
Surge voltage category
III
Connection data
Type of connection
PUSH IN
Tightening torque, min.
0.4 Nm
Tightening torque, max.
0.6 Nm
Clamping range, rated connection
2.5 mm²
Clamping range, min.
0.5 mm²
Clamping range, max.
2.5 mm²
Wire connection cross section AWG, min.
AWG 26
Wire connection cross section AWG, max.
AWG 14
Important note
Product information
The analogue voltage converter ACT20P-VM-AO-S measures DC or AC voltages. The analogue input signal is linearly converted into an analogue output signal (current or voltage) and galvanically isolated.
Features
Configuration and monitoring are performed via FDT/DTM-Software „WI-Manager“.
Signal and alarm triggering upon exceeding limit values or reverse polarity DC input voltage
Front LED indicates operation status
3-way galvanic isolation between input, output and power supply.
Downloads
Approval/Certificate/Document of Conformity
Engineering Data
CADENAS eCATALOG
CAX data
Software
User Documentation
Catalogues
Catalogues in PDF-format
Classifications
ETIM 6.0
EC002653
ETIM 7.0
EC002653
ETIM 8.0
EC002653
ETIM 9.0
EC002653
ECLASS 9.0
27-21-01-20
ECLASS 9.1
27-21-01-20
ECLASS 10.0
27-21-01-20
ECLASS 11.0
27-21-01-20
ECLASS 12.0
27-21-01-20
ECLASS 13.0
27-21-01-20
Approvals
Approvals
ROHS
Conform
UL File Number Search
UL Website
Certificate No. (cURus)
E469563
Order No.:
7760054114
Type of connection:
Screw connection
Type:
ACT20P-CI-CO-S
Version:
Signal converter/insulator, Input : 0(4)-20 mA, Output : 0(4)-20 mA, Signal converter/isolator, HART®
Order No.:
2489680000
Type of connection:
PUSH IN
Type:
ACT20P-CI-CO-P
Version:
Signal converter/insulator, Input : 0(4)-20 mA, Output : 0(4)-20 mA, Signal converter/isolator, HART®
Order No.:
1506200000
Type of connection:
Screw connection
Type:
ACT20P-CI-CO-P-S
Version:
Signal converter/insulator, Input : 0(4)-20 mA, Output : 0(4)-20 mA, Voltage supply also via CH20M rail bus, Signal converter/isolator, HART®
Order No.:
2514620000
Type of connection:
PUSH IN
Type:
ACT20P-CI-CO-P-P
Version:
Signal converter/insulator, Input : 0(4)-20 mA, Output : 0(4)-20 mA, Voltage supply also via CH20M rail bus, Signal converter/isolator, HART®
Order No.:
7760054117
Type of connection:
Screw connection
Type:
ACT20P-2CI-2CO-12-S
Version:
Signal converter/insulator, Input : 2 x 0(4) - 20 mA, Output : 2 x 4-20 mA, Signal converter/isolator, HART®
Order No.:
2489730000
Type of connection:
PUSH IN
Type:
ACT20P-2CI-2CO-12-P
Version:
Signal converter/insulator, Input : 2 x 0(4) - 20 mA, Output : 2 x 4-20 mA, Signal converter/isolator, HART®
Order No.:
2514650000
Type of connection:
PUSH IN
Type:
ACT20P-2CI-2CO-12-P-P
Version:
Signal converter/insulator, Input : 2 x 0(4) - 20 mA, Output : 0(4)-20 mA, Voltage supply also via CH20M rail bus, Signal converter/isolator, HART®
Order No.:
1506210000
Type of connection:
Screw connection
Type:
ACT20P-2CI-2CO-12P-S
Version:
Signal converter/insulator, Input : 2 x 0(4) - 20 mA, Output : 0(4)-20 mA, Voltage supply also via CH20M rail bus, Signal converter/isolator, HART®
Order No.:
1540010000
Type of connection:
Screw connection
Type:
ACT20P-CI-VO-S
Version:
Signal converter/insulator, Input : 0(4)-20 mA, Output : 0-10 V, Signal converter/isolator
Order No.:
2489740000
Type of connection:
PUSH IN
Type:
ACT20P-CI-VO-P
Version:
Signal converter/insulator, Input : 0(4)-20 mA, Output : 0-10 V, Signal converter/isolator
Order No.:
1537750000
Type of connection:
Screw connection
Type:
ACT20P-CI-VO-P-S
Version:
Signal converter/insulator, Input : 0(4)-20 mA, Output : 0-10 V, Voltage supply also via CH20M rail bus, Signal converter/isolator
Order No.:
2514640000
Type of connection:
PUSH IN
Type:
ACT20P-CI-VO-P-P
Version:
Signal converter/insulator, Input : 0(4)-20 mA, Output : 0-10 V, Voltage supply also via CH20M rail bus, Signal converter/isolator
Order No.:
7760054131
Type of connection:
Screw connection
Type:
ACT20P-VI3-VO3-S
Version:
Signal converter/insulator, Input : -10…0…+10 V, Output : -10…0…+10 V, Signal converter/isolator
Order No.:
7760054306
Type of connection:
Screw connection
Type:
ACT20P-VM-AO-S
Version:
Signal converter/insulator, Input : AC/DC voltage, 0...600 V DC, 0…440 V AC, Output : 0-10 V, 0(4)-20 mA, Signal converter/isolator
Version
Signal converter/insulator, Input : AC/DC voltage, 0...600 V DC, 0…440 V AC, Output : 0-10 V, 0(4)-20 mA, Signal converter/isolator
Order No.
7760054360
Type
ACT20P-VM-AO-P
GTIN (EAN)
4050118559743
Qty.
1 pc(s).
Depth
114.3 mm
Depth (inches)
4.5 inch
Height
119.2 mm
Height (inches)
4.693 inch
Width
22.5 mm
Width (inches)
0.886 inch
Net weight
140 g
Storage temperature
-40 °C...85 °C
Operating temperature
-20 °C...60 °C
Humidity at operating temperature
0...95 % (no condensation)
Humidity
5...95 %, no condensation
SIL in compliance with IEC 61508
None
MTTF
140 a
REACH SVHC
Lead 7439-92-1
SCIP
2f6dd957-421a-46db-a0c2-cf1609156924
Input resistance
1 MΩ±5%
Input voltage
0…30 V DC, 0…60 V DC, 0…300 V DC, 0…440 V DC, 0…660 V DC, 0…60 V AC, 0…144 V AC, 0…300 V AC, 0…440 V AC
Number of inputs
1
Load impedance current
≤ 500 Ω
Number of outputs
1
Output current
0...20 mA, 4...20 mA
Output voltage, note
0...10 V
Type
active, connected control must be passive
load impedance voltage
≥ 10 kΩ
Accuracy
0.5 % FSR
Configuration
With FDT/DTM software, Requires configuration adapter 8978580000 CBX200 USB
Galvanic isolation
between input ⁄ output ⁄ supply
Power consumption
≤ 100 mA @ 24 VDC, ≤ 120mA @ 24V AC
Protection degree
IP20
Rail
TS 35
Step response time
<300 ms
Temperature coefficient
≤ 200 ppm/K
Voltage supply
24…240 VUC (±10%)
EMC standards
EN 61326-1, EN 61000-6-2, EN 61000-6-4
Galvanic isolation
between input ⁄ output ⁄ supply
Impulse withstand voltage
4 kV (1.2/50 μs) input - output, 4 kV (1.2/50 μs) input / supply, 2.5 kV (1.2/50 μs) output / supply
Insulation voltage
1.5 kV AC output / supply, 2 kV AC input / output, 2 kV AC input / supply
Pollution severity
2
Rated voltage
600 V input / output, 600 V input / supply, 300 V output / supply
Surge voltage category
III
Type of connection
PUSH IN
Tightening torque, min.
0.4 Nm
Tightening torque, max.
0.6 Nm
Clamping range, rated connection
2.5 mm²
Clamping range, min.
0.5 mm²
Clamping range, max.
2.5 mm²
Wire connection cross section AWG, min.
AWG 26
Wire connection cross section AWG, max.
AWG 14
Product information
The analogue voltage converter ACT20P-VM-AO-S measures DC or AC voltages. The analogue input signal is linearly converted into an analogue output signal (current or voltage) and galvanically isolated.
Features
Configuration and monitoring are performed via FDT/DTM-Software „WI-Manager“.
Signal and alarm triggering upon exceeding limit values or reverse polarity DC input voltage
Front LED indicates operation status
3-way galvanic isolation between input, output and power supply.
ETIM 6.0
EC002653
ETIM 7.0
EC002653
ETIM 8.0
EC002653
ETIM 9.0
EC002653
ECLASS 9.0
27-21-01-20
ECLASS 9.1
27-21-01-20
ECLASS 10.0
27-21-01-20
ECLASS 11.0
27-21-01-20
ECLASS 12.0
27-21-01-20
ECLASS 13.0
27-21-01-20
Approvals
ROHS
Conform
UL File Number Search
UL Website
Certificate No. (cURus)
E469563
Order No.:
7760054114
Type of connection:
Screw connection
Type:
ACT20P-CI-CO-S
Version:
Signal converter/insulator, Input : 0(4)-20 mA, Output : 0(4)-20 mA, Signal converter/isolator, HART®
Order No.:
2489680000
Type of connection:
PUSH IN
Type:
ACT20P-CI-CO-P
Version:
Signal converter/insulator, Input : 0(4)-20 mA, Output : 0(4)-20 mA, Signal converter/isolator, HART®
Order No.:
1506200000
Type of connection:
Screw connection
Type:
ACT20P-CI-CO-P-S
Version:
Signal converter/insulator, Input : 0(4)-20 mA, Output : 0(4)-20 mA, Voltage supply also via CH20M rail bus, Signal converter/isolator, HART®
Order No.:
2514620000
Type of connection:
PUSH IN
Type:
ACT20P-CI-CO-P-P
Version:
Signal converter/insulator, Input : 0(4)-20 mA, Output : 0(4)-20 mA, Voltage supply also via CH20M rail bus, Signal converter/isolator, HART®
Order No.:
7760054117
Type of connection:
Screw connection
Type:
ACT20P-2CI-2CO-12-S
Version:
Signal converter/insulator, Input : 2 x 0(4) - 20 mA, Output : 2 x 4-20 mA, Signal converter/isolator, HART®
Order No.:
2489730000
Type of connection:
PUSH IN
Type:
ACT20P-2CI-2CO-12-P
Version:
Signal converter/insulator, Input : 2 x 0(4) - 20 mA, Output : 2 x 4-20 mA, Signal converter/isolator, HART®
Order No.:
2514650000
Type of connection:
PUSH IN
Type:
ACT20P-2CI-2CO-12-P-P
Version:
Signal converter/insulator, Input : 2 x 0(4) - 20 mA, Output : 0(4)-20 mA, Voltage supply also via CH20M rail bus, Signal converter/isolator, HART®
Order No.:
1506210000
Type of connection:
Screw connection
Type:
ACT20P-2CI-2CO-12P-S
Version:
Signal converter/insulator, Input : 2 x 0(4) - 20 mA, Output : 0(4)-20 mA, Voltage supply also via CH20M rail bus, Signal converter/isolator, HART®
Order No.:
1540010000
Type of connection:
Screw connection
Type:
ACT20P-CI-VO-S
Version:
Signal converter/insulator, Input : 0(4)-20 mA, Output : 0-10 V, Signal converter/isolator
Order No.:
2489740000
Type of connection:
PUSH IN
Type:
ACT20P-CI-VO-P
Version:
Signal converter/insulator, Input : 0(4)-20 mA, Output : 0-10 V, Signal converter/isolator
Order No.:
1537750000
Type of connection:
Screw connection
Type:
ACT20P-CI-VO-P-S
Version:
Signal converter/insulator, Input : 0(4)-20 mA, Output : 0-10 V, Voltage supply also via CH20M rail bus, Signal converter/isolator
Order No.:
2514640000
Type of connection:
PUSH IN
Type:
ACT20P-CI-VO-P-P
Version:
Signal converter/insulator, Input : 0(4)-20 mA, Output : 0-10 V, Voltage supply also via CH20M rail bus, Signal converter/isolator
Order No.:
7760054131
Type of connection:
Screw connection
Type:
ACT20P-VI3-VO3-S
Version:
Signal converter/insulator, Input : -10…0…+10 V, Output : -10…0…+10 V, Signal converter/isolator
Order No.:
7760054306
Type of connection:
Screw connection
Type:
ACT20P-VM-AO-S
Version:
Signal converter/insulator, Input : AC/DC voltage, 0...600 V DC, 0…440 V AC, Output : 0-10 V, 0(4)-20 mA, Signal converter/isolator
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.