Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Analogue Signal Conditioning
Power Supplies
Electronics Housings
Lightning and Surge Protection
Photovoltaics
e-mobility
Fieldbus Distributors
Network-compatible current measuring transducers ACT20C
intrinsically safe signal converter - ACT20X
signal converter and process monitoring - ACT20P
Space-saving signal converter - ACT20M
Signal converter in terminal block format - MCZ
Compact standard signal isolators - PicoPak
Process monitoring displays
Analogue-digital / digital-analogue converter
Signal - & serial interface converter– WAVESERIES
Configuration software
Accessories
Signal converters
Passive isolator
Signal splitter
Temperature transducer
Measuring and monitoring relay
Current measuring transducer
Bridge measuring transducer
Frequency converters
Universal
General ordering data
Version
Analogue signal converter, Input : 2 x 0(4) - 20 mA, (loop powered), Output : 2 x 0(4) - 20 mA, Signal converter/isolator, dual channel, Input current loop feed
Order No.
7760054358
Type
ACT20P-2CI-2CO-ILP-P
GTIN (EAN)
4050118559729
Qty.
1 pc(s).
Dimensions and weights
Depth
114 mm
Depth (inches)
4.488 inch
Height
127.1 mm
Height (inches)
5.004 inch
Width
12.5 mm
Width (inches)
0.492 inch
Net weight
140 g
Temperatures
Operating temperature
-20 °C...60 °C
Humidity at operating temperature
0...95 % (no condensation)
Humidity
5...95 %, no condensation
Probability of failure
SIL in compliance with IEC 61508
None
Environmental Product Compliance
REACH SVHC
Lead 7439-92-1
SCIP
2f6dd957-421a-46db-a0c2-cf1609156924
RoHS Compliance Status
Compliant with exemption
RoHS Exemption (if applicable/known)
7a, 7cI
Input
Number of inputs
2
Sensor
4- wire sensor (with own power supply), Current source
Voltage drop, current input
≤ 3.5 V @ I input = 20 mA
Output
Load impedance current
≤ 600 Ω
Number of outputs
2
Output current
0…20 mA (if input: 0…20 mA), 4…20 mA (if input: 4…20 mA)
Type
active, connected control must be passive
General data
Accuracy
<0.1 % of end value
Configuration
none
Protection degree
IP20
Rail
TS 35
Step response time
≤ 1 ms
Voltage supply
Loop powered, via 4…20 mA input
Insulation coordination
EMC standards
EN 61326-1, EN 61000-6-2, EN 61000-6-4
Impulse withstand voltage
4 kV (1.2/50 µs)
Insulation voltage
2 kV inputs / outputs
Rated voltage
300 V
Data for Ex applications (ATEX)
Marking
II 3 G Ex ec IIC T6 Gc
Connection data
Type of connection
PUSH IN
Tightening torque, min.
0.4 Nm
Tightening torque, max.
0.6 Nm
Clamping range, rated connection
2.5 mm²
Clamping range, min.
0.5 mm²
Clamping range, max.
2.5 mm²
Wire connection cross section AWG, min.
AWG 26
Wire connection cross section AWG, max.
AWG 14
Wire cross-section, solid, min.
0.2 mm²
Wire cross-section, solid, max.
2.5 mm²
Wire connection cross section, finely stranded, min.
0.5 mm²
Wire connection cross section, finely stranded, max.
2.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.
0.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.
2.5 mm²
Important note
Product information
The ACT20P-2CI-2CO-ILP-S (dual channel) fixed passive isolators isolate analogue standard current source signals.
An analogue input current signal is converted linear and galvanic isolated into an analogue output current signal.
The device is powered via the input current loop.
Features
Galvanic 4-way isolation (dual-channel device) between all inputs and outputs.
Classifications
ETIM 6.0
EC002653
ETIM 7.0
EC002653
ETIM 8.0
EC002653
ETIM 9.0
EC002653
ECLASS 9.0
27-21-01-20
ECLASS 9.1
27-21-01-20
ECLASS 10.0
27-21-01-20
ECLASS 11.0
27-21-01-20
ECLASS 12.0
27-21-01-20
ECLASS 13.0
27-21-01-20
ECLASS 14.0
27-21-01-20
Order No.:
7760054123
Type of connection:
Screw connection
Type:
ACT20P-CI-CO-ILP-S
Version:
Signal converter/insulator, Input : 0(4)-20 mA, (loop powered), Output : 0(4)-20 mA, Signal converter/isolator, Input current loop feed
Order No.:
7760054357
Type of connection:
PUSH IN
Type:
ACT20P-CI-CO-ILP-P
Version:
Signal converter/insulator, Input : 0(4)-20 mA, (loop powered), Output : 0(4)-20 mA, Signal converter/isolator, Input current loop feed
Order No.:
7760054124
Type of connection:
Screw connection
Type:
ACT20P-2CI-2CO-ILP-S
Version:
Signal converter/insulator, Input : 2 x 0(4) - 20 mA, (loop powered), Output : 2 x 0(4) - 20 mA, Signal converter/isolator, dual channel, Input current loop feed
Order No.:
7760054118
Type of connection:
Screw connection
Type:
ACT20P-CI1-CO-OLP-S
Version:
Signal converter/insulator, Input : 0-20 mA, Output : 4-20 mA, (loop powered), Signal converter/isolator, Output current loop powered
Order No.:
7760054353
Type of connection:
PUSH IN
Type:
ACT20P-CI1-CO-OLP-P
Version:
Signal converter/insulator, Input : 0-20 mA, Output : 4-20 mA, (loop powered), Signal converter/isolator, Output current loop powered
Order No.:
7760054119
Type of connection:
Screw connection
Type:
ACT20P-CI2-CO-OLP-S
Version:
Signal converter/insulator, Input : 4-20 mA, Output : 4-20 mA, (loop powered), Signal converter/isolator, Output current loop powered
Order No.:
7760054354
Type of connection:
PUSH IN
Type:
ACT20P-CI2-CO-OLP-P
Version:
Signal converter/insulator, Input : 4-20 mA, Output : 4-20 mA, (loop powered), Signal converter/isolator, Output current loop powered
Order No.:
7760054122
Type of connection:
Screw connection
Type:
ACT20P-CI-2CO-OLP-S
Version:
Signal converter/insulator, Input : 4-20 mA, Output : 2 x 4-20 mA, (loop powered), Signal distributor, Output current loop powered
Order No.:
2619390000
Type of connection:
PUSH IN
Type:
ACT20P-CI-2CO-OLP-P
Version:
Signal converter/insulator, Input : 4-20 mA, Output : 2 x 4-20 mA, (loop powered), Signal distributor, Output current loop powered
Order No.:
7760054121
Type of connection:
Screw connection
Type:
ACT20P-VI-CO-OLP-S
Version:
Signal converter/insulator, Input : 0-10 V, Output : 4-20 mA, (loop powered), Capacitive, Output current loop powered
Order No.:
7760054356
Type of connection:
PUSH IN
Type:
ACT20P-VI-CO-OLP-P
Version:
Signal converter/insulator, Input : 0-10 V, Output : 4-20 mA, (loop powered), Signal converter/isolator, Output current loop powered
Order No.:
7760054120
Type of connection:
Screw connection
Type:
ACT20P-VI1-CO-OLP-S
Version:
Signal converter/insulator, Input : 0-5 V, Output : 4-20 mA, (loop powered), Signal converter/isolator, Output current loop powered
Order No.:
7760054355
Type of connection:
PUSH IN
Type:
ACT20P-VI1-CO-OLP-P
Version:
Signal converter/insulator, Input : 0-5 V, Output : 4-20 mA, (loop powered), Signal converter/isolator, Output current loop powered
Version
Analogue signal converter, Input : 2 x 0(4) - 20 mA, (loop powered), Output : 2 x 0(4) - 20 mA, Signal converter/isolator, dual channel, Input current loop feed
Order No.
7760054358
Type
ACT20P-2CI-2CO-ILP-P
GTIN (EAN)
4050118559729
Qty.
1 pc(s).
Depth
114 mm
Depth (inches)
4.488 inch
Height
127.1 mm
Height (inches)
5.004 inch
Width
12.5 mm
Width (inches)
0.492 inch
Net weight
140 g
Operating temperature
-20 °C...60 °C
Humidity at operating temperature
0...95 % (no condensation)
Humidity
5...95 %, no condensation
SIL in compliance with IEC 61508
None
REACH SVHC
Lead 7439-92-1
SCIP
2f6dd957-421a-46db-a0c2-cf1609156924
RoHS Compliance Status
Compliant with exemption
RoHS Exemption (if applicable/known)
7a, 7cI
Number of inputs
2
Sensor
4- wire sensor (with own power supply), Current source
Voltage drop, current input
≤ 3.5 V @ I input = 20 mA
Load impedance current
≤ 600 Ω
Number of outputs
2
Output current
0…20 mA (if input: 0…20 mA), 4…20 mA (if input: 4…20 mA)
Type
active, connected control must be passive
Accuracy
<0.1 % of end value
Configuration
none
Protection degree
IP20
Rail
TS 35
Step response time
≤ 1 ms
Voltage supply
Loop powered, via 4…20 mA input
EMC standards
EN 61326-1, EN 61000-6-2, EN 61000-6-4
Impulse withstand voltage
4 kV (1.2/50 µs)
Insulation voltage
2 kV inputs / outputs
Rated voltage
300 V
Marking
II 3 G Ex ec IIC T6 Gc
Type of connection
PUSH IN
Tightening torque, min.
0.4 Nm
Tightening torque, max.
0.6 Nm
Clamping range, rated connection
2.5 mm²
Clamping range, min.
0.5 mm²
Clamping range, max.
2.5 mm²
Wire connection cross section AWG, min.
AWG 26
Wire connection cross section AWG, max.
AWG 14
Wire cross-section, solid, min.
0.2 mm²
Wire cross-section, solid, max.
2.5 mm²
Wire connection cross section, finely stranded, min.
0.5 mm²
Wire connection cross section, finely stranded, max.
2.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.
0.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.
2.5 mm²
Product information
The ACT20P-2CI-2CO-ILP-S (dual channel) fixed passive isolators isolate analogue standard current source signals.
An analogue input current signal is converted linear and galvanic isolated into an analogue output current signal.
The device is powered via the input current loop.
Features
Galvanic 4-way isolation (dual-channel device) between all inputs and outputs.
ETIM 6.0
EC002653
ETIM 7.0
EC002653
ETIM 8.0
EC002653
ETIM 9.0
EC002653
ECLASS 9.0
27-21-01-20
ECLASS 9.1
27-21-01-20
ECLASS 10.0
27-21-01-20
ECLASS 11.0
27-21-01-20
ECLASS 12.0
27-21-01-20
ECLASS 13.0
27-21-01-20
ECLASS 14.0
27-21-01-20
Approvals
ROHS
Conform
UL File Number Search
UL Website
Certificate No. (cURusEX)
E338066
Certificate no. (cULus)
E469563
Order No.:
7760054123
Type of connection:
Screw connection
Type:
ACT20P-CI-CO-ILP-S
Version:
Signal converter/insulator, Input : 0(4)-20 mA, (loop powered), Output : 0(4)-20 mA, Signal converter/isolator, Input current loop feed
Order No.:
7760054357
Type of connection:
PUSH IN
Type:
ACT20P-CI-CO-ILP-P
Version:
Signal converter/insulator, Input : 0(4)-20 mA, (loop powered), Output : 0(4)-20 mA, Signal converter/isolator, Input current loop feed
Order No.:
7760054124
Type of connection:
Screw connection
Type:
ACT20P-2CI-2CO-ILP-S
Version:
Signal converter/insulator, Input : 2 x 0(4) - 20 mA, (loop powered), Output : 2 x 0(4) - 20 mA, Signal converter/isolator, dual channel, Input current loop feed
Order No.:
7760054118
Type of connection:
Screw connection
Type:
ACT20P-CI1-CO-OLP-S
Version:
Signal converter/insulator, Input : 0-20 mA, Output : 4-20 mA, (loop powered), Signal converter/isolator, Output current loop powered
Order No.:
7760054353
Type of connection:
PUSH IN
Type:
ACT20P-CI1-CO-OLP-P
Version:
Signal converter/insulator, Input : 0-20 mA, Output : 4-20 mA, (loop powered), Signal converter/isolator, Output current loop powered
Order No.:
7760054119
Type of connection:
Screw connection
Type:
ACT20P-CI2-CO-OLP-S
Version:
Signal converter/insulator, Input : 4-20 mA, Output : 4-20 mA, (loop powered), Signal converter/isolator, Output current loop powered
Order No.:
7760054354
Type of connection:
PUSH IN
Type:
ACT20P-CI2-CO-OLP-P
Version:
Signal converter/insulator, Input : 4-20 mA, Output : 4-20 mA, (loop powered), Signal converter/isolator, Output current loop powered
Order No.:
7760054122
Type of connection:
Screw connection
Type:
ACT20P-CI-2CO-OLP-S
Version:
Signal converter/insulator, Input : 4-20 mA, Output : 2 x 4-20 mA, (loop powered), Signal distributor, Output current loop powered
Order No.:
2619390000
Type of connection:
PUSH IN
Type:
ACT20P-CI-2CO-OLP-P
Version:
Signal converter/insulator, Input : 4-20 mA, Output : 2 x 4-20 mA, (loop powered), Signal distributor, Output current loop powered
Order No.:
7760054121
Type of connection:
Screw connection
Type:
ACT20P-VI-CO-OLP-S
Version:
Signal converter/insulator, Input : 0-10 V, Output : 4-20 mA, (loop powered), Capacitive, Output current loop powered
Order No.:
7760054356
Type of connection:
PUSH IN
Type:
ACT20P-VI-CO-OLP-P
Version:
Signal converter/insulator, Input : 0-10 V, Output : 4-20 mA, (loop powered), Signal converter/isolator, Output current loop powered
Order No.:
7760054120
Type of connection:
Screw connection
Type:
ACT20P-VI1-CO-OLP-S
Version:
Signal converter/insulator, Input : 0-5 V, Output : 4-20 mA, (loop powered), Signal converter/isolator, Output current loop powered
Order No.:
7760054355
Type of connection:
PUSH IN
Type:
ACT20P-VI1-CO-OLP-P
Version:
Signal converter/insulator, Input : 0-5 V, Output : 4-20 mA, (loop powered), Signal converter/isolator, Output current loop powered
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.