Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Analogue Signal Conditioning
Power Supplies
Electronics Housings
Lightning and Surge Protection
Photovoltaics
e-mobility
Fieldbus Distributors
Network-compatible current measuring transducers ACT20C
intrinsically safe signal converter - ACT20X
signal converter and process monitoring - ACT20P
Space-saving signal converter - ACT20M
Signal converter in terminal block format - MCZ
Compact standard signal isolators - PicoPak
Process monitoring displays
Analogue-digital / digital-analogue converter
Signal - & serial interface converter– WAVESERIES
Configuration software
Accessories
EPAK
General ordering data
Order No.
7760054179
Type
EPAK-CI-CO-ILP
GTIN (EAN)
6944169701504
Qty.
1 pc(s).
Dimensions and weights
Depth
89 mm
Depth (inches)
3.504 inch
Height
100 mm
Height (inches)
3.937 inch
Width
17.5 mm
Width (inches)
0.689 inch
Length
100 mm
Length (inches)
3.937 inch
Net weight
80 g
Temperatures
Storage temperature
-40 °C...85 °C
Operating temperature
-20 °C...60 °C
Humidity at operating temperature
5...95 %, no condensation
Probability of failure
SIL in compliance with IEC 61508
None
Environmental Product Compliance
REACH SVHC
Lead 7439-92-1
SCIP
6a722fc5-2d22-41b4-9544-5b95e45a4b77
RoHS Compliance Status
Compliant with exemption
RoHS Exemption (if applicable/known)
7a, 7cI
Input
Input current
4...20 mA (current loop)
Number of inputs
1
Sensor
Sensor with own supply
Voltage drop, current input
<3 V
Output
Load impedance current
≤450 Ω
Number of outputs
1
Output current
4...20 mA
Output (digital)
Max. switching voltage, AC
0 V
Max. switching voltage, DC
0 V
Number of digital outputs
0
Rated switching current
0.1 A
Output (analogue)
Number of analogue outputs
1
General data
Accuracy
0.15 % v. FSR
Configuration
none
Galvanic isolation
between input/output
Protection degree
IP20
Step response time
≤ 100 ms
Temperature coefficient
≤ 150 ppm/K
Voltage supply
Loop powered, via 4…20 mA input
Insulation coordination
EMC standards
EN 61326
Galvanic isolation
between input/output
Impulse withstand voltage
4 kV (1.2/50 µs)
Insulation voltage
2 kVeff
Pollution severity
2
Rated voltage
300 V ACrms
Surge voltage category
III
Connection data
Type of connection
Screw connection
Tightening torque, min.
0.4 Nm
Tightening torque, max.
0.6 Nm
Clamping range, rated connection
2 mm²
Clamping range, min.
0.5 mm²
Clamping range, max.
2 mm²
Wire connection cross section AWG, min.
AWG 30
Wire connection cross section AWG, max.
AWG 14
Classifications
ETIM 6.0
EC002653
ETIM 7.0
EC002653
ETIM 8.0
EC002653
ETIM 9.0
EC002653
ECLASS 9.0
27-21-01-20
ECLASS 9.1
27-21-01-20
ECLASS 10.0
27-21-01-20
ECLASS 11.0
27-21-01-20
ECLASS 12.0
27-21-01-20
ECLASS 13.0
27-21-01-20
ECLASS 14.0
27-21-01-20
Approvals
Approvals
ROHS
Conform
Order No.
7760054179
Type
EPAK-CI-CO-ILP
GTIN (EAN)
6944169701504
Qty.
1 pc(s).
Depth
89 mm
Depth (inches)
3.504 inch
Height
100 mm
Height (inches)
3.937 inch
Width
17.5 mm
Width (inches)
0.689 inch
Length
100 mm
Length (inches)
3.937 inch
Net weight
80 g
Storage temperature
-40 °C...85 °C
Operating temperature
-20 °C...60 °C
Humidity at operating temperature
5...95 %, no condensation
SIL in compliance with IEC 61508
None
REACH SVHC
Lead 7439-92-1
SCIP
6a722fc5-2d22-41b4-9544-5b95e45a4b77
RoHS Compliance Status
Compliant with exemption
RoHS Exemption (if applicable/known)
7a, 7cI
Input current
4...20 mA (current loop)
Number of inputs
1
Sensor
Sensor with own supply
Voltage drop, current input
<3 V
Load impedance current
≤450 Ω
Number of outputs
1
Output current
4...20 mA
Max. switching voltage, AC
0 V
Max. switching voltage, DC
0 V
Number of digital outputs
0
Rated switching current
0.1 A
Number of analogue outputs
1
Accuracy
0.15 % v. FSR
Configuration
none
Galvanic isolation
between input/output
Protection degree
IP20
Step response time
≤ 100 ms
Temperature coefficient
≤ 150 ppm/K
Voltage supply
Loop powered, via 4…20 mA input
EMC standards
EN 61326
Galvanic isolation
between input/output
Impulse withstand voltage
4 kV (1.2/50 µs)
Insulation voltage
2 kVeff
Pollution severity
2
Rated voltage
300 V ACrms
Surge voltage category
III
Type of connection
Screw connection
Tightening torque, min.
0.4 Nm
Tightening torque, max.
0.6 Nm
Clamping range, rated connection
2 mm²
Clamping range, min.
0.5 mm²
Clamping range, max.
2 mm²
Wire connection cross section AWG, min.
AWG 30
Wire connection cross section AWG, max.
AWG 14
ETIM 6.0
EC002653
ETIM 7.0
EC002653
ETIM 8.0
EC002653
ETIM 9.0
EC002653
ECLASS 9.0
27-21-01-20
ECLASS 9.1
27-21-01-20
ECLASS 10.0
27-21-01-20
ECLASS 11.0
27-21-01-20
ECLASS 12.0
27-21-01-20
ECLASS 13.0
27-21-01-20
ECLASS 14.0
27-21-01-20
Approvals
ROHS
Conform
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.