General ordering data

Version Signal converter/insulator, Input : I/U universal, Output : I/U universal, Signal converter/isolator, universal
Order No. 7760054130
Type ACT20P-AI-AO-S
GTIN (EAN) 6944169684524
Qty. 1 pc(s).

Dimensions and weights

Depth 114 mm
Depth (inches) 4.488 inch
Height 119.2 mm
Height (inches) 4.693 inch
Width 12.5 mm
Width (inches) 0.492 inch
Net weight 50 g

Temperatures

Storage temperature -40 °C...85 °C
Operating temperature -20 °C...60 °C
Humidity at operating temperature 0...95 % (no condensation)
Humidity 5...95 %, no condensation

Probability of failure

SIL in compliance with IEC 61508 None

Environmental Product Compliance

REACH SVHC Lead 7439-92-1

Input

Input current 0...20 mA, 4…20mA
Input resistance, current ≤ 100 Ω
Input resistance, voltage 100 kΩ
Input voltage 0(2)…10 V, 0(1)…5 V
Number of inputs 1

Output

Load impedance current ≤ 550 Ω
Number of outputs 1
Output current Adjustable, 0...20 mA, 4...20 mA
Output voltage, note 0(1)...5 V, 0(2)...10 V
Type active, connected control must be passive
load impedance voltage ≥ 600 Ω

Output (digital)

Max. switching voltage, AC 0 V
Max. switching voltage, DC 0 V
Rated switching current 0.1 A

General data

Accuracy <0.1 % of end value
Configuration DIP switch
Current consumption 50 mA @ IOUT = 20 mA
Galvanic isolation 3-way isolator, between input ⁄ output ⁄ supply
Protection degree IP20
Rail TS 35
Step response time ≤ 100 ms
Temperature coefficient ≤ 100 ppm/K
Voltage supply 24 V DC ± 20 %

Insulation coordination

EMC standards EN 61326-1
Galvanic isolation 3-way isolator, between input ⁄ output ⁄ supply
Impulse withstand voltage 4 kV (1.2/50 µs)
Insulation voltage 2 kV inputs / outputs / power supply
Pollution severity 2
Surge voltage category III
Test voltage 0.3 kV

Connection data

Type of connection Screw connection
Tightening torque, min. 0.4 Nm
Tightening torque, max. 0.6 Nm
Clamping range, rated connection 2.5 mm²
Clamping range, min. 0.5 mm²
Clamping range, max. 2.5 mm²
Wire connection cross section AWG, min. AWG 26
Wire connection cross section AWG, max. AWG 12

Downloads

Classifications

ETIM 6.0 EC002653
ETIM 7.0 EC002653
ETIM 8.0 EC002653
ETIM 9.0 EC002653
ECLASS 9.0 27-21-01-20
ECLASS 9.1 27-21-01-20
ECLASS 10.0 27-21-01-20
ECLASS 11.0 27-21-01-20
ECLASS 12.0 27-21-01-20
ECLASS 13.0 27-21-01-20
ECLASS 14.0 27-21-01-20

Approvals

Approvals CE
ROHS Conform

Related products

Type of connection: Screw connection
Order No.: 1481970000
Type: ACT20P-PRO DCDC II-S
Version:
Signal converter/insulator, 24…230 V AC/DC power supply, Input : I/U universal, Output : I/U universal
 
Type of connection: PUSH IN
Order No.: 1481960000
Type: ACT20P-PRO DCDC II-P
Version:
Signal converter/insulator, 24…230 V AC/DC power supply, Input : I/U universal, Output : I/U universal
 
Type of connection: Screw connection
Order No.: 2816690000
Type: ACT20P-PRO DCDC II-24-S
Version:
Analogue signal converter, 24 V DC power supply, Input : I/U universal, Output : I/U universal
 
Type of connection: PUSH IN
Order No.: 2816700000
Type: ACT20P-PRO DCDC II-24-P
Version:
Analogue signal converter, 24 V DC power supply, Input : I/U universal, Output : I/U universal
 
Type of connection: Screw connection
Order No.: 1477420000
Type: ACT20P-AI-AO-DC-S
Version:
Signal converter/insulator, Input : I/U universal, Output : I/U universal, Signal converter/isolator, 24 V DC power supply
 
Type of connection: PUSH IN
Order No.: 2456860000
Type: ACT20P-AI-AO-DC-P
Version:
Signal converter/insulator, Input : I/U universal, Output : I/U universal, Signal converter/isolator, 24 V DC power supply
 
Type of connection: Screw connection
Order No.: 1545720000
Type: ACT20P-AI-AO-AC-S
Version:
Signal converter/insulator, Input : I/U universal, Output : I/U universal, Signal converter/isolator, 90…264 V AC power supply
 
Type of connection: PUSH IN
Order No.: 2495700000
Type: ACT20P-AI-AO-AC-P
Version:
Signal converter/insulator, Input : I/U universal, Output : I/U universal, Signal converter/isolator, 90…264 V AC power supply
 
Type of connection: Screw connection
Order No.: 1453210000
Type: ACT20P-UI-AO-DO-LP
Version:
Limit value monitoring, Input : universal U, I, R,ϑ, Output : 4-20 mA, (loop powered), Transistor (Alarm)
 
Type of connection: PUSH IN
Order No.: 2456850000
Type: ACT20P-UI-AO-DO-LP-P
Version:
Signal converter/insulator, Limit value monitoring, Input : universal U, I, R,ϑ, Output : 4-20 mA, (loop powered), Transistor (Alarm)
 
Contact
Weidmüller Interface GmbH & Co. KG
 
+49 5231 14-0
+49 5231 14-292083
More information
Decentralised automation solutions
Energy Management Solutions
Industrial Analytics
Industrial IoT Solutions
More information
Mobility Concepts
Photovoltaics
Wind Solutions
Workplace Solutions
More information
Single Pair Ethernet
Weidmüller Configurator
Support & Service
Contact
Disposal Instructions
Engineering data
Repairs and replacement parts