Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Isolating amplifier and measuring transducer
Power Supplies
Electronics Housings
Lightning and Surge Protection
e-mobility
Photovoltaics
Fieldbus Distributors
Network-compatible measuring transducer - ACT20C
intrinsically safe signal converter - ACT20X
signal converter and process monitoring - ACT20P
Space-saving signal converter - ACT20M
Signal converter in terminal block format - MCZ
Compact standard signal isolators - PicoPak
Process monitoring displays
Analogue-digital / digital-analogue converter
Signal - & serial interface converter– WAVESERIES
Configuration software
Accessories
Isolating amplifiers
Passive isolator
Isolating amplifiers with splitter function
Temperature transducer
Trip amplifier
Current measuring transducer
Strain gauge transducer
Frequency transducer
Universal transducer
Universal transducer, loop powered
Serial interface converter
General ordering data
Version
Passive isolator, Input : 0(4)-20 mA, (loop powered), Output : 0(4)-20 mA, Input current loop feed
Order No.
7760054123
Type
ACT20P-CI-CO-ILP-S
GTIN (EAN)
6944169656637
Qty.
1 pc(s).
Dimensions and weights
Depth
114 mm
Depth (inches)
4.488 inch
Height
117.2 mm
Height (inches)
4.614 inch
Width
12.5 mm
Width (inches)
0.492 inch
Net weight
100 g
Temperatures
Storage temperature
-40 °C...85 °C
Operating temperature
-20 °C...60 °C
Humidity at operating temperature
0...95 % (no condensation)
Humidity
5...95 %, no condensation
Probability of failure
SIL in compliance with IEC 61508
None
Environmental Product Compliance
RoHS Compliance Status
Compliant with exemption
RoHS Exemption (if applicable/known)
7a, 7cI
REACH SVHC
Lead 7439-92-1
SCIP
2f6dd957-421a-46db-a0c2-cf1609156924
Input
Input current
0(4)...20 mA current loop
Number of inputs
1
Sensor
4- wire sensor (with own power supply), Current source
Voltage drop, current input
3.8 V
Output
Load impedance current
≤ 600 Ω
Number of outputs
1
Output current
0…20 mA (if input: 0…20 mA), 4…20 mA (if input: 4…20 mA)
Type
active, connected control must be passive
Output (digital)
Max. switching voltage, AC
0 V
Max. switching voltage, DC
0 V
Rated switching current
0.1 A
General data
Accuracy
<0.1 % of end value
Configuration
none
Galvanic isolation
2-way isolator
Nominal power consumption
2 VA
Operating altitude
≤ 2000 m
Protection degree
IP20
Rail
TS 35
Step response time
≤ 1 ms
Temperature coefficient
≤ 100 ppm/K
Voltage supply
Loop powered, via 4…20 mA input
Insulation coordination
EMC standards
EN 61326-1, EN 61000-6-2, EN 61000-6-4
Galvanic isolation
2-way isolator
Impulse withstand voltage
3 kV (1.2/50µs)
Insulation voltage
2.5 kV (input / output)
Pollution severity
2
Rated voltage
300 V
Surge voltage category
III
Data for Ex applications (ATEX)
Marking
II 3 G Ex ec IIC T6 Gc
Connection data
Type of connection
Screw connection
Tightening torque, min.
0.4 Nm
Tightening torque, max.
0.6 Nm
Clamping range, rated connection
2.5 mm²
Clamping range, min.
0.5 mm²
Clamping range, max.
2.5 mm²
Wire connection cross section AWG, min.
AWG 26
Wire connection cross section AWG, max.
AWG 12
Important note
Product information
The ACT20P-CI-CO-ILP-S fixed passive isolators isolate analogue standard current source signals. An analogue input current signal is converted linear and galvanic isolated into an analogue output current signal. The device is powered via the input current loop.
Features
Galvanic 2-way isolation (single-channel device) between input and output.
Classifications
ETIM 6.0
EC002653
ETIM 7.0
EC002653
ETIM 8.0
EC002653
ETIM 9.0
EC002653
ECLASS 9.0
27-21-01-20
ECLASS 9.1
27-21-01-20
ECLASS 10.0
27-21-01-20
ECLASS 11.0
27-21-01-20
ECLASS 12.0
27-21-01-20
ECLASS 13.0
27-21-01-20
ECLASS 14.0
27-21-01-20
Order No.:
7760054357
Type of connection:
PUSH IN
Type:
ACT20P-CI-CO-ILP-P
Version:
Passive isolator, Input : 0(4)-20 mA, (loop powered), Output : 0(4)-20 mA, Input current loop feed
Order No.:
7760054124
Type of connection:
Screw connection
Type:
ACT20P-2CI-2CO-ILP-S
Version:
Passive isolator, Input : 2 x 0(4) - 20 mA, (loop powered), Output : 2 x 0(4) - 20 mA, Input current loop feed
Order No.:
7760054358
Type of connection:
PUSH IN
Type:
ACT20P-2CI-2CO-ILP-P
Version:
Passive isolator, Input : 2 x 0(4) - 20 mA, (loop powered), Output : 2 x 0(4) - 20 mA, Input current loop feed
Order No.:
7760054118
Type of connection:
Screw connection
Type:
ACT20P-CI1-CO-OLP-S
Version:
Passive isolator, Input : 0-20 mA, Output : 4-20 mA, (loop powered), Signal converter/isolator, Output current loop powered
Order No.:
7760054353
Type of connection:
PUSH IN
Type:
ACT20P-CI1-CO-OLP-P
Version:
Passive isolator, Input : 0-20 mA, Output : 4-20 mA, (loop powered), Signal converter/isolator, Output current loop powered
Order No.:
7760054119
Type of connection:
Screw connection
Type:
ACT20P-CI2-CO-OLP-S
Version:
Passive isolator, Input : 4-20 mA, Output : 4-20 mA, (loop powered), Signal converter/isolator, Output current loop powered
Order No.:
7760054354
Type of connection:
PUSH IN
Type:
ACT20P-CI2-CO-OLP-P
Version:
Passive isolator, Input : 4-20 mA, Output : 4-20 mA, (loop powered), Signal converter/isolator, Output current loop powered
Order No.:
7760054122
Type of connection:
Screw connection
Type:
ACT20P-CI-2CO-OLP-S
Version:
Passive isolator, Input : 4-20 mA, Output : 2 x 4-20 mA, (loop powered), Signal distributor, Output current loop powered
Order No.:
2619390000
Type of connection:
PUSH IN
Type:
ACT20P-CI-2CO-OLP-P
Version:
Passive isolator, Input : 4-20 mA, Output : 2 x 4-20 mA, (loop powered), Signal distributor, Output current loop powered
Order No.:
7760054121
Type of connection:
Screw connection
Type:
ACT20P-VI-CO-OLP-S
Version:
Passive isolator, Input : 0-10 V, Output : 4-20 mA, (loop powered), Capacitive, Output current loop powered
Order No.:
7760054356
Type of connection:
PUSH IN
Type:
ACT20P-VI-CO-OLP-P
Version:
Passive isolator, Input : 0-10 V, Output : 4-20 mA, (loop powered), Signal converter/isolator, Output current loop powered
Order No.:
7760054120
Type of connection:
Screw connection
Type:
ACT20P-VI1-CO-OLP-S
Version:
Passive isolator, Input : 0-5 V, Output : 4-20 mA, (loop powered), Signal converter/isolator, Output current loop powered
Order No.:
7760054355
Type of connection:
PUSH IN
Type:
ACT20P-VI1-CO-OLP-P
Version:
Passive isolator, Input : 0-5 V, Output : 4-20 mA, (loop powered), Signal converter/isolator, Output current loop powered
Version
Passive isolator, Input : 0(4)-20 mA, (loop powered), Output : 0(4)-20 mA, Input current loop feed
Order No.
7760054123
Type
ACT20P-CI-CO-ILP-S
GTIN (EAN)
6944169656637
Qty.
1 pc(s).
Depth
114 mm
Depth (inches)
4.488 inch
Height
117.2 mm
Height (inches)
4.614 inch
Width
12.5 mm
Width (inches)
0.492 inch
Net weight
100 g
Storage temperature
-40 °C...85 °C
Operating temperature
-20 °C...60 °C
Humidity at operating temperature
0...95 % (no condensation)
Humidity
5...95 %, no condensation
SIL in compliance with IEC 61508
None
RoHS Compliance Status
Compliant with exemption
RoHS Exemption (if applicable/known)
7a, 7cI
REACH SVHC
Lead 7439-92-1
SCIP
2f6dd957-421a-46db-a0c2-cf1609156924
Input current
0(4)...20 mA current loop
Number of inputs
1
Sensor
4- wire sensor (with own power supply), Current source
Voltage drop, current input
3.8 V
Load impedance current
≤ 600 Ω
Number of outputs
1
Output current
0…20 mA (if input: 0…20 mA), 4…20 mA (if input: 4…20 mA)
Type
active, connected control must be passive
Max. switching voltage, AC
0 V
Max. switching voltage, DC
0 V
Rated switching current
0.1 A
Accuracy
<0.1 % of end value
Configuration
none
Galvanic isolation
2-way isolator
Nominal power consumption
2 VA
Operating altitude
≤ 2000 m
Protection degree
IP20
Rail
TS 35
Step response time
≤ 1 ms
Temperature coefficient
≤ 100 ppm/K
Voltage supply
Loop powered, via 4…20 mA input
EMC standards
EN 61326-1, EN 61000-6-2, EN 61000-6-4
Galvanic isolation
2-way isolator
Impulse withstand voltage
3 kV (1.2/50µs)
Insulation voltage
2.5 kV (input / output)
Pollution severity
2
Rated voltage
300 V
Surge voltage category
III
Marking
II 3 G Ex ec IIC T6 Gc
Type of connection
Screw connection
Tightening torque, min.
0.4 Nm
Tightening torque, max.
0.6 Nm
Clamping range, rated connection
2.5 mm²
Clamping range, min.
0.5 mm²
Clamping range, max.
2.5 mm²
Wire connection cross section AWG, min.
AWG 26
Wire connection cross section AWG, max.
AWG 12
Product information
The ACT20P-CI-CO-ILP-S fixed passive isolators isolate analogue standard current source signals. An analogue input current signal is converted linear and galvanic isolated into an analogue output current signal. The device is powered via the input current loop.
Features
Galvanic 2-way isolation (single-channel device) between input and output.
ETIM 6.0
EC002653
ETIM 7.0
EC002653
ETIM 8.0
EC002653
ETIM 9.0
EC002653
ECLASS 9.0
27-21-01-20
ECLASS 9.1
27-21-01-20
ECLASS 10.0
27-21-01-20
ECLASS 11.0
27-21-01-20
ECLASS 12.0
27-21-01-20
ECLASS 13.0
27-21-01-20
ECLASS 14.0
27-21-01-20
Approvals
ROHS
Conform
UL File Number Search
UL Website
Certificate No. (cURusEX)
E338066
Certificate no. (cULus)
E469563
Order No.:
7760054357
Type of connection:
PUSH IN
Type:
ACT20P-CI-CO-ILP-P
Version:
Passive isolator, Input : 0(4)-20 mA, (loop powered), Output : 0(4)-20 mA, Input current loop feed
Order No.:
7760054124
Type of connection:
Screw connection
Type:
ACT20P-2CI-2CO-ILP-S
Version:
Passive isolator, Input : 2 x 0(4) - 20 mA, (loop powered), Output : 2 x 0(4) - 20 mA, Input current loop feed
Order No.:
7760054358
Type of connection:
PUSH IN
Type:
ACT20P-2CI-2CO-ILP-P
Version:
Passive isolator, Input : 2 x 0(4) - 20 mA, (loop powered), Output : 2 x 0(4) - 20 mA, Input current loop feed
Order No.:
7760054118
Type of connection:
Screw connection
Type:
ACT20P-CI1-CO-OLP-S
Version:
Passive isolator, Input : 0-20 mA, Output : 4-20 mA, (loop powered), Signal converter/isolator, Output current loop powered
Order No.:
7760054353
Type of connection:
PUSH IN
Type:
ACT20P-CI1-CO-OLP-P
Version:
Passive isolator, Input : 0-20 mA, Output : 4-20 mA, (loop powered), Signal converter/isolator, Output current loop powered
Order No.:
7760054119
Type of connection:
Screw connection
Type:
ACT20P-CI2-CO-OLP-S
Version:
Passive isolator, Input : 4-20 mA, Output : 4-20 mA, (loop powered), Signal converter/isolator, Output current loop powered
Order No.:
7760054354
Type of connection:
PUSH IN
Type:
ACT20P-CI2-CO-OLP-P
Version:
Passive isolator, Input : 4-20 mA, Output : 4-20 mA, (loop powered), Signal converter/isolator, Output current loop powered
Order No.:
7760054122
Type of connection:
Screw connection
Type:
ACT20P-CI-2CO-OLP-S
Version:
Passive isolator, Input : 4-20 mA, Output : 2 x 4-20 mA, (loop powered), Signal distributor, Output current loop powered
Order No.:
2619390000
Type of connection:
PUSH IN
Type:
ACT20P-CI-2CO-OLP-P
Version:
Passive isolator, Input : 4-20 mA, Output : 2 x 4-20 mA, (loop powered), Signal distributor, Output current loop powered
Order No.:
7760054121
Type of connection:
Screw connection
Type:
ACT20P-VI-CO-OLP-S
Version:
Passive isolator, Input : 0-10 V, Output : 4-20 mA, (loop powered), Capacitive, Output current loop powered
Order No.:
7760054356
Type of connection:
PUSH IN
Type:
ACT20P-VI-CO-OLP-P
Version:
Passive isolator, Input : 0-10 V, Output : 4-20 mA, (loop powered), Signal converter/isolator, Output current loop powered
Order No.:
7760054120
Type of connection:
Screw connection
Type:
ACT20P-VI1-CO-OLP-S
Version:
Passive isolator, Input : 0-5 V, Output : 4-20 mA, (loop powered), Signal converter/isolator, Output current loop powered
Order No.:
7760054355
Type of connection:
PUSH IN
Type:
ACT20P-VI1-CO-OLP-P
Version:
Passive isolator, Input : 0-5 V, Output : 4-20 mA, (loop powered), Signal converter/isolator, Output current loop powered
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.