EM220-RTU-4DI2DO
         

Icon
 

General ordering data

Version Power measurement/display for 1-, 3-phase mains, use of CT, pulse output,, digital input/output,, Modbus RTU
Order No. 7760051005
Type EM220-RTU-4DI2DO
GTIN (EAN) 6944169818219
Qty. 1 pc(s).

Dimensions and weights

Depth 74 mm
Depth (inches) 2.913 inch
Height 96 mm
Height (inches) 3.78 inch
Width 96 mm
Width (inches) 3.78 inch
Net weight 360 g

Temperatures

Storage temperature -40 °C...70 °C
Operating temperature -25 °C...55 °C
Humidity 0...90 % (no condensation)

Environmental Product Compliance

REACH SVHC /

Measuring current input

Current-measuring channels 3
Max. current 9999 A
Measuring accuracy for current 0.5 %
Rated current via current transformer 1 A/5 A

Measuring voltage input

Four-wire system Yes
Frequency range, max. 65 Hz
Frequency range, min. 45 Hz
Low voltage network 1 phase 2 wire (L + N), 1 phase 2 wire (L1 + L2), 3 phase 3 wire (L1 + L2 + L3), 3 phase 4 wire (L1 + L2 + L3 + N)
Measurement range, voltage L-L, AC 50…600 V
Measurement range, voltage L-N, AC 50…345 V
Measuring accuracy for voltage 0.5 %
Three-wire system Yes
Voltage type AC

Communication

Parity none, even, odd
Stop bits 1, 2
Interface RS485
Protocol Modbus RTU

Inputs/outputs

Digital output configurable Yes
Input type 3 phase AC (3P, 3P +N), Secondary side of a current transformer 0-1 A or 0-5 A
Number of digital inputs
Number of digital outputs
Temperature input No

Measurement data recording

Update interval register 1 s
Software EM configuration tools

Technical data

Display monitoring (monitor) LCD digital
Display value Voltage, current measured value, Apparent power, Reactive power, Power factor, Frequency, Import / export active power demand, Total import / export active energy, Total import / export reactive energy, Total system power demand
Max. current 9999 A
Pollution severity 2
Power factor input ± 0.01
Protection degree IP20, Front panel: IP51
Rated current via current transformer 1 A/5 A
Type of mounting Frontpanel mounting
Version Power measurement/display for 1-, 3-phase mains, use of CT, pulse output,, digital input/output,, Modbus RTU
Measurement range, voltage L-N, AC 50…345 V
Measurement range, voltage L-L, AC 50…600 V
Surge voltage category III
Voltage supply 75…270 V AC, 100…380 V DC
Three-wire system Yes
Four-wire system Yes
Sampling frequency 50/60 Hz 14.4 kHz
Continuous measurements Yes
Measurement result per second 1 s
Current-measuring channels 3
Measuring accuracy for voltage 0.5 %
Measuring accuracy for current 0.5 %
Measurement accuracy for active energy (kWh, .../5 A) Class 0.5S (IEC 62053-22), Class 0.5 (IEC 61557-12)
Clock Yes

Insulation coordination

Pollution severity 2
Surge voltage category III

Connection data

Stripping length 8 mm
Type of connection Screw connection
Wire cross-section, solid, min. 0.5 mm²
Wire cross-section, solid, max. 2.5 mm²
Wire connection cross section, finely stranded, min. 0.5 mm²
Wire connection cross section, finely stranded, max. 2.5 mm²
Wire connection cross section, finely stranded, two clampable wires, min. 0.5 mm²
Wire cross-section, finely stranded, two clampable wires, max. 2.5 mm²

Downloads

Classifications

ETIM 6.0 EC002301
ETIM 7.0 EC002301
ETIM 8.0 EC002301
ETIM 9.0 EC002301
ECLASS 9.0 27-14-23-30
ECLASS 9.1 27-21-03-01
ECLASS 10.0 27-14-23-30
ECLASS 11.0 27-14-23-30
ECLASS 12.0 27-14-23-30
ECLASS 13.0 27-14-23-30

Approvals

Approvals CE
ROHS Conform

Related products

Type of connection: Screw connection
Order No.: 7760051002
Type: EM110-RTU-2P
Version:
Power measurement/display for 1-phase mains, use of CT, pulse output,, Modbus RTU
 
Type of connection: Screw connection
Order No.: 7760051001
Type: EM111-RTU-2P
Version:
Power measurement/display for 1-phase mains, 45 A, direct measurement, pulse output,, Modbus RTU
 
Type of connection: Screw connection
Order No.: 7760051004
Type: EM120-RTU-2P
Version:
Power measurement/display for 1-, 3-phase mains, use of CT, pulse output,, Modbus RTU
 
Type of connection: Screw connection
Order No.: 7760051003
Type: EM122-RTU-2P
Version:
Power measurement/display for 1-, 3-phase mains, 100 A, direct measurement, pulse output,, Modbus RTU
 
Type of connection: Screw connection
Order No.: 7760051006
Type: EM220-RTU-4DI2DO-GW
Version:
Power measurement/display for 1-, 3-phase mains, use of CT, pulse output,, digital input/output,, Modbus RTU, Modbus TCP/IP, Gateway
 
Contact
Weidmüller Interface GmbH & Co. KG
 
+49 5231 14-0
+49 5231 14-292083
More information
Decentralised automation solutions
Energy Management Solutions
Industrial Analytics
Industrial IoT Solutions
More information
Mobility Concepts
Photovoltaics
Wind Solutions
Workplace Solutions
More information
Single Pair Ethernet
Weidmüller Configurator
Support & Service
Contact
Disposal Instructions
Engineering data
Repairs and replacement parts