3 phase AC (3P, 3P +N), Secondary side of a current transformer 0-1 A or 0-5 A
Number of pulse outputs
2
Temperature input
No
Measurement data recording
Update interval register
100 ms
Software
EM configuration tools
Technical data
Display
LCD
Display monitoring (monitor)
LCD digital
Display value
Voltage, current measured value, Apparent power, Reactive power, Power factor, Frequency, Import / export active power demand, Total import / export active energy, Total import / export reactive energy, Total system power demand
Max. current
5000 A
Pollution severity
2
Power factor input
1 %
Protection degree
IP51
Rated current
via current transformer 1 A/5 A
Type of mounting
DIN rail
Version
Power measurement/display for 1-, 3-phase mains, use of CT, pulse output,, Modbus RTU
Measurement range, voltage L-N, AC
138…276 V
Measurement range, voltage L-L, AC
240…480 V
Surge voltage category
III
Voltage supply
85…275 V AC
Three-wire system
Yes
Quadrants
4
Sampling frequency 50/60 Hz
14.4 kHz
Measurement result per second
100 ms
Current-measuring channels
3
Measuring accuracy for voltage
0.5 %
Measuring accuracy for current
0.5 %
Measurement accuracy for active energy (kWh, .../5 A)
Class 0.5
Insulation coordination
Pollution severity
2
Surge voltage category
III
Connection data
Stripping length
8 mm
Type of connection
Screw connection
Wire connection cross section, finely stranded, min.
Voltage, current measured value, Apparent power, Reactive power, Power factor, Frequency, Import / export active power demand, Total import / export active energy, Total import / export reactive energy, Total system power demand
Max. current
5000 A
Pollution severity
2
Power factor input
1 %
Protection degree
IP51
Rated current
via current transformer 1 A/5 A
Type of mounting
DIN rail
Version
Power measurement/display for 1-, 3-phase mains, use of CT, pulse output,, Modbus RTU
Measurement range, voltage L-N, AC
138…276 V
Measurement range, voltage L-L, AC
240…480 V
Surge voltage category
III
Voltage supply
85…275 V AC
Three-wire system
Yes
Quadrants
4
Sampling frequency 50/60 Hz
14.4 kHz
Measurement result per second
100 ms
Current-measuring channels
3
Measuring accuracy for voltage
0.5 %
Measuring accuracy for current
0.5 %
Measurement accuracy for active energy (kWh, .../5 A)
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.