Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Analogue Signal Conditioning
Power Supplies
Electronics Housings
Lightning and Surge Protection
e-mobility
Photovoltaics
Fieldbus Distributors
SPDs for energy systems
SPDs for instrumentation and control (I&C)
SPDs for data interfaces
Accessories
AC voltage
Photovoltaics
DIN rail TS 35
40mm busbars
Type I
Type II
Type III
VPU Type I Series
VPU Type II Series
VPU AC II
VPU AC II+III S
VPU AC II US series
VPU AC II F with integrated fuse
230/400V IoT
275 V / 20 kA
440 V / 20 kA
Optical status indicator
Optical status indicator & remote alert
Spare arrester
VPU AC II+III 2 R 440/20 S
General ordering data
Version
Surge voltage arrester, Low voltage, with remote contact, TN-S, TN-C, IT with N, IT without N
Order No.
2908450000
Type
VPU AC II+III 2 R 440/20 S
GTIN (EAN)
4099986190658
Qty.
1 pc(s).
Dimensions and weights
Depth
70 mm
Depth (inches)
2.756 inch
Height
105 mm
Height (inches)
4.134 inch
Width
18 mm
Width (inches)
0.709 inch
Net weight
165 g
Temperatures
Operating temperature
-40 °C...85 °C
Environmental Product Compliance
REACH SVHC
/
Connection data, remote alert
Connection type
Screw connection
Cross-section for connected wire, solid core, max.
1.5 mm²
Cross-section for connected wire, solid core, min.
0.2 mm²
Max. torque
0.4 Nm
Stripping length
5 mm
General data
Colour
grey
Design
Installation housing; 1TE, Insta IP 20
Operating altitude
≤ 2000 m
Optical function display
green = OK; red = arrester is defective - replace
Protection degree
IP20 in installed state
Rail
TS 35
Segment
Power distribution
UL 94 flammability rating
V-0
Version
with remote contact
Insulation coordination acc. to EN 50178
Pollution severity
2
Surge voltage category
III
Rated data IEC / EN
Combined pulse UOC
6 kV
Discharge current (type III)
3 kA
Discharge current Imax (8/20µs) wire-PE
20 kA
Discharge current In (8/20µs) wire-PE
10 kA
Frequency range, max.
60 Hz
Frequency range, min.
50 Hz
Fuse
No Fuse neccessary ≤100 A gG
Low voltage network
TN-S, TN-C, IT with N, IT without N
Max. continuous voltage, Uc (AC)
440 V
Number of poles
2
Protection level Up at IN (L-PE) (type III)
≤1 kV
Protection level Up at IN (L/N-PE)
≤ 1.7 kV, ≤ 1.4 kV
Rated voltage (AC)
230 V
Requirements category acc. to IEC 61643-11
Type II, Type III
Requirements class, acc. to EN 61643-11
T2, T3
Response time
≤ 25 ns
Short-circuit current rating ISCCR
25 kA
Signalling contact
250 V / 0,5 A
Standards
IEC 61643-11, EN 61643-11
Temporary surge voltage (over-voltage) - TOV
440 V
Voltage type
AC
Connection data
Conductor connection cross-section PE, solid, max.
35 mm²
Conductor connection cross-section PE, stranded, max.
35 mm²
Wire connection method
Screw connection
Type of connection
Screw connection
Stripping length, rated connection
15 mm
Tightening torque, max.
1.2 Nm
Wire cross-section, solid, min.
2.5 mm²
Wire cross-section, solid, max.
10 mm²
Wire connection cross section, finely stranded, min.
2.5 mm²
Wire connection cross section, finely stranded, max.
6 mm²
Connection cross-section, stranded, min.
2.5 mm²
Connection cross-section, stranded, max.
10 mm²
Guarantee
Time interval
5 years
Important note
Product information
For use in DC applications, please use the fuse of SIBA Type NH2XL aR/aSF DC 1500 V
Downloads
Approval/Certificate/Document of Conformity
Engineering Data
Tender specification
User Documentation
Catalogues
Catalogues in PDF-format
Classifications
ETIM 6.0
EC000941
ETIM 7.0
EC000941
ETIM 8.0
EC000941
ETIM 9.0
EC000941
ECLASS 9.0
27-13-08-05
ECLASS 9.1
27-13-08-05
ECLASS 10.0
27-13-08-05
ECLASS 11.0
27-13-08-05
ECLASS 12.0
27-17-90-90
ECLASS 13.0
27-17-90-90
Approvals
Approvals
ROHS
Conform
Order No.:
2908510000
Type of connection:
Screw connection
Type:
VPU AC II+III 1+1 R 440/20 S
Version:
Surge voltage arrester, Low voltage, with remote contact, TN-S, TT
Order No.:
2908470000
Type of connection:
Screw connection
Type:
VPU AC II+III 3 R 440/20 S
Version:
Surge voltage arrester, Low voltage, with remote contact, TN-S, TN-C, IT with N, IT without N
Order No.:
2908530000
Type of connection:
Screw connection
Type:
VPU AC II+III 3+1 R 440/20 S
Version:
Surge voltage arrester, Low voltage, with remote contact, TN-S, TT
Order No.:
2908490000
Type of connection:
Screw connection
Type:
VPU AC II+III 4 R 440/20 S
Version:
Surge voltage arrester, Low voltage, with remote contact, TN-S, TN-C, IT with N, IT without N
Version
Surge voltage arrester, Low voltage, with remote contact, TN-S, TN-C, IT with N, IT without N
Order No.
2908450000
Type
VPU AC II+III 2 R 440/20 S
GTIN (EAN)
4099986190658
Qty.
1 pc(s).
Depth
70 mm
Depth (inches)
2.756 inch
Height
105 mm
Height (inches)
4.134 inch
Width
18 mm
Width (inches)
0.709 inch
Net weight
165 g
Operating temperature
-40 °C...85 °C
Connection type
Screw connection
Cross-section for connected wire, solid core, max.
1.5 mm²
Cross-section for connected wire, solid core, min.
0.2 mm²
Max. torque
0.4 Nm
Stripping length
5 mm
Colour
grey
Design
Installation housing; 1TE, Insta IP 20
Operating altitude
≤ 2000 m
Optical function display
green = OK; red = arrester is defective - replace
Protection degree
IP20 in installed state
Rail
TS 35
Segment
Power distribution
UL 94 flammability rating
V-0
Version
with remote contact
Pollution severity
2
Surge voltage category
III
Combined pulse UOC
6 kV
Discharge current (type III)
3 kA
Discharge current Imax (8/20µs) wire-PE
20 kA
Discharge current In (8/20µs) wire-PE
10 kA
Frequency range, max.
60 Hz
Frequency range, min.
50 Hz
Fuse
No Fuse neccessary ≤100 A gG
Low voltage network
TN-S, TN-C, IT with N, IT without N
Max. continuous voltage, Uc (AC)
440 V
Number of poles
2
Protection level Up at IN (L-PE) (type III)
≤1 kV
Protection level Up at IN (L/N-PE)
≤ 1.7 kV, ≤ 1.4 kV
Rated voltage (AC)
230 V
Requirements category acc. to IEC 61643-11
Type II, Type III
Requirements class, acc. to EN 61643-11
T2, T3
Response time
≤ 25 ns
Short-circuit current rating ISCCR
25 kA
Signalling contact
250 V / 0,5 A
Standards
IEC 61643-11, EN 61643-11
Temporary surge voltage (over-voltage) - TOV
440 V
Voltage type
AC
Conductor connection cross-section PE, solid, max.
35 mm²
Conductor connection cross-section PE, stranded, max.
35 mm²
Wire connection method
Screw connection
Type of connection
Screw connection
Stripping length, rated connection
15 mm
Tightening torque, max.
1.2 Nm
Wire cross-section, solid, min.
2.5 mm²
Wire cross-section, solid, max.
10 mm²
Wire connection cross section, finely stranded, min.
2.5 mm²
Wire connection cross section, finely stranded, max.
6 mm²
Connection cross-section, stranded, min.
2.5 mm²
Connection cross-section, stranded, max.
10 mm²
Product information
For use in DC applications, please use the fuse of SIBA Type NH2XL aR/aSF DC 1500 V
Approval/Certificate/Document of Conformity
Engineering Data
Tender specification
User Documentation
Catalogues
Catalogues in PDF-format
ETIM 6.0
EC000941
ETIM 7.0
EC000941
ETIM 8.0
EC000941
ETIM 9.0
EC000941
ECLASS 9.0
27-13-08-05
ECLASS 9.1
27-13-08-05
ECLASS 10.0
27-13-08-05
ECLASS 11.0
27-13-08-05
ECLASS 12.0
27-17-90-90
ECLASS 13.0
27-17-90-90
Approvals
ROHS
Conform
Order No.:
2908510000
Type of connection:
Screw connection
Type:
VPU AC II+III 1+1 R 440/20 S
Version:
Surge voltage arrester, Low voltage, with remote contact, TN-S, TT
Order No.:
2908470000
Type of connection:
Screw connection
Type:
VPU AC II+III 3 R 440/20 S
Version:
Surge voltage arrester, Low voltage, with remote contact, TN-S, TN-C, IT with N, IT without N
Order No.:
2908530000
Type of connection:
Screw connection
Type:
VPU AC II+III 3+1 R 440/20 S
Version:
Surge voltage arrester, Low voltage, with remote contact, TN-S, TT
Order No.:
2908490000
Type of connection:
Screw connection
Type:
VPU AC II+III 4 R 440/20 S
Version:
Surge voltage arrester, Low voltage, with remote contact, TN-S, TN-C, IT with N, IT without N
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.