Product wizard 
 Website 
English
Deutsch
Français
Italiano
Japanese
Español
Svenska
Россия
繁體中文
简体中文
Polska
한국어
Čeština
Magyar
  
0
0
Quick access
PVN DC 2IN/1OUTX2 2MPPT SPD1R WM4C 1.1KV
         

Icon
Icon
Icon
Icon
Icon
Icon
Icon
Icon
Icon
 

General ordering data

Version Photovoltaics, Combiner Box, 1100 V, 2 MPP's, 2 Inputs / 1 Output per MPP, Surge protection I / II, WM4C
Order No. 2866340000
Type PVN DC 2IN/1OUTX2 2MPPT SPD1R WM4C 1.1KV
GTIN (EAN) 4064675604020
Qty. 1 pc(s).

Dimensions and weights

Depth 132 mm
Depth (inches) 5.197 inch
Height 234 mm
Height (inches) 9.213 inch
Width 200 mm
Width (inches) 7.874 inch
Net weight 2,000 g

Temperatures

Ambient temperature -40 °C...+50 °C
Humidity 5...95 %, no condensation

Guarantee

Time interval 5 years

Electrical characteristics

Current per Maximum Power Point, max. 30 A
Rated DC current per connection
Current per string, max. 30 A
Rated short-term current resistance
Rated current 37.5 A
Rated DC voltage 1,100 V DC

Enclosure

Connection type String Plug WM4C
Enclosure attachment Via mounting foots
Impact resistance IK08 in accordance with IEC 62208, IK10 in accordance with IEC 62262
Insulating material Polyester glass-fibre reinforced, Polycarbonate
Switch disconnector execution no switch
Type of mounting 4 screws, Wall mounting

General data

Installation location Protected outdoor area (>1 km from sea)
Protection degree IP65
Standards EN 61439-2, IEC 61439-2

Inputs

Amount of Maximum Power Points 2 MPP
DC Input + & -
Wire connection
Type of connection WM4C plug-in connector
Compatible cable crossection EN 50618:2015, TÜV 2 Pfg1169/08.07
Wire cross-section, min. 4 mm²
Wire cross-section, max. 6 mm²
Cable entry
Number of cable entries 4
Functional earth connector
Cable entry
Number of cable entries 1
Wire connection
Type of connection Screw connection
Flexible, max. H05(07) V-K 25 mm²
w. wire end ferrule, DIN 46228 pt 1, max. 16 mm²
Fuse type Neither fuse cartridge nor holder
Max. number of DC inputs per Maximum Power Point 2 inputs connected in parallel
Surge protection auxiliary contact
Wire connection
Type of connection Tension clamp connection with actuator
Flexible, max. H05(07) V-K 1.5 mm²
w. wire end ferrule, DIN 46228 pt 1, max. 1.5 mm²
Cable entry
Number of cable entries 1

Outputs

DC Output + & -
Wire connection
Type of connection WM4C plug-in connector
Compatible cable crossection TÜV 2 Pfg1169/08.07, EN 50618:2015
Wire cross-section, min. 4 mm²
Wire cross-section, max. 6 mm²
Max. number of DC outputs per Maximum Power Point 1 output

Surge protection DC side

Discharge current In (8/20 µs) 20 kA
Discharge current, max. (8/20 µs) 40 kA
Lightning test current Iimp (10/350 µs) 6.25 kA
Maximum continuous operating voltage UCPV mode +/-, -/PE, +/PE 1,100 V DC
PV system voltage, max. Ucpv 1,100 V
Protection level Up (+/- , -/PE , +/PE) ≤ 3.8 kV
Protection level Up (+/-) ≤ 3.8 kV
Protection level Up (+/PE) ≤ 3.8 kV
Protection level Up (-/PE) ≤ 3.8 kV
Requirements class Type I/II
Short-circuit curent ISCPV 11,000 A
Standards EN 61439-2, IEC 61439-2
Standby power consumption PC < 0.2 W
Total discharge current Itotal ( 8/20µs) 50 kA
Total discharge current Itotal (10/350µs) 12.5 kA

Downloads

Classifications

ETIM 6.0 EC002928
ETIM 7.0 EC002928
ETIM 8.0 EC003857
ECLASS 9.0 22-57-92-03
ECLASS 9.1 22-57-02-90
ECLASS 10.0 22-57-02-90
ECLASS 11.0 22-57-02-92
ECLASS 12.0 22-57-02-92

Approvals

Approvals CE

Related products

Amount of Maximum Power Points:
Connection type String:
Requirements class:
Order No.: 2791920000
Amount of Maximum Power Points: 1 MPP
Connection type String: Plug WM4C
Type: PVN1M1I2SXFXV1O1TXPX11
Requirements class: Type I/II
Version:
Photovoltaics, Combiner Box, 1100 V, 1 MPP, 2 Inputs / 1 Output per MPP, Surge protection I / II, WM4C
Additional text:
PVN DC 2IN/1OUTx1 1MPPT SPD1R WM4 1.1kV
 
Order No.: 2866300000
Amount of Maximum Power Points: 1 MPP
Connection type String: Plug MC4-Evo 2
Type: PVN1M1I2SXFXV1O2TXPX11
Requirements class: Type I/II
Version:
Photovoltaics, Combiner Box, 1100 V, 1 MPP, 2 Inputs / 1 Output per MPP, Surge protection I / II, MC4-Evo 2
 
Order No.: 2791930000
Amount of Maximum Power Points: 1 MPP
Connection type String: Internal terminal (with cable gland feed-through)
Type: PVN1M1I2SXFXV1O0TXPX11
Requirements class: Type I/II
Version:
Photovoltaics, Combiner Box, 1100 V, 1 MPP, 2 Inputs / 1 Output per MPP, Surge protection I / II, Cable gland
Additional text:
PVN DC 2IN/1OUTx1 1MPPT SPD1R CG 1.1kV
 
Order No.: 2791940000
Amount of Maximum Power Points: 1 MPP
Connection type String: Plug WM4C
Type: PVN1M1I2SXFXV2O1TXPX11
Requirements class: Type II
Version:
Photovoltaics, Combiner Box, 1100 V, 1 MPP, 2 Inputs / 1 Output per MPP, Surge protection II, WM4C
Additional text:
PVN DC 2IN/1OUTx1 1MPPT SPD2R WM4 1.1kV
 
Order No.: 2866310000
Amount of Maximum Power Points: 1 MPP
Connection type String: Plug MC4-Evo 2
Type: PVN1M1I2SXFXV2O2TXPX11
Requirements class: Type II
Version:
Photovoltaics, Combiner Box, 1100 V, 1 MPP, 2 Inputs / 1 Output per MPP, Surge protection II, MC4-Evo 2
 
Order No.: 2791950000
Amount of Maximum Power Points: 1 MPP
Connection type String: Internal terminal (with cable gland feed-through)
Type: PVN1M1I2SXFXV2O0TXPX11
Requirements class: Type II
Version:
Photovoltaics, Combiner Box, 1100 V, 1 MPP, 2 Inputs / 1 Output per MPP, Surge protection II, Cable gland
Additional text:
PVN DC 2IN/1OUTx1 1MPPT SPD2R CG 1.1kV
 
Order No.: 2683170000
Amount of Maximum Power Points: 1 MPP
Connection type String: Plug WM4C
Type: PVN1M1I3SXFXV1O1TXPX10
Requirements class: Type I/II
Version:
Photovoltaics, Combiner Box, 1000 V, 1 MPP, 3 Inputs / 3 Outputs per MPP, Surge protection I / II, WM4C
Delivery status:
This article will no longer be available in the future.
Additional text:
PVN DC 3IN/3OUTx1 1MPPT SPD1R WM4 1kV
 
Order No.: 2683200000
Amount of Maximum Power Points: 1 MPP
Connection type String: Plug WM4C
Type: PVN1M1I3S0FXV1O1TXPX10
Requirements class: Type I/II
Version:
Photovoltaics, Combiner Box, 1 MPP, 3 Inputs / 3 Outputs per MPP, Surge protection I / II, Switch disconnector, WM4C, 1000 V
Delivery status:
This article will no longer be available in the future.
Additional text:
PVN DC 3IN/3OUTx1 1MPPT SW SPD1R WM4 1kV
 
Order No.: 2683110000
Amount of Maximum Power Points: 1 MPP
Connection type String: Internal terminal (with cable gland feed-through)
Type: PVN1M1I3SXFXV1O0TXPX10
Requirements class: Type I/II
Version:
Photovoltaics, Combiner Box, 1000 V, 1 MPP, 3 Inputs / 3 Outputs per MPP, Surge protection I / II, Cable gland
Delivery status:
This article will no longer be available in the future.
Additional text:
PVN DC 3IN/3OUTx1 1MPPT SPD1R CG 1kV
 
Order No.: 2683140000
Amount of Maximum Power Points: 1 MPP
Connection type String: Internal terminal (with cable gland feed-through)
Type: PVN1M1I3S0FXV1O0TXPX10
Requirements class: Type I/II
Version:
Photovoltaics, Combiner Box, 1000 V, 1 MPP, 3 Inputs / 3 Outputs per MPP, Surge protection I / II, Switch disconnector, Cable gland
Delivery status:
This article will no longer be available in the future.
Additional text:
PVN DC 3IN/3OUTx1 1MPPT SW SPD1R CG 1kV
 
Order No.: 2683370000
Amount of Maximum Power Points: 1 MPP
Connection type String: Plug WM4C
Type: PVN1M1I3SXFXV2O1TXPX10
Requirements class: Type II
Version:
Photovoltaics, Combiner Box, 1000 V, 1 MPP, 3 Inputs / 3 Outputs per MPP, Surge protection II, WM4C
Delivery status:
This article will no longer be available in the future.
Additional text:
PVN DC 3IN/3OUTx1 SPD2R WM4 1kV
 
Order No.: 2683400000
Amount of Maximum Power Points: 1 MPP
Connection type String: Plug WM4C
Type: PVN1M1I3S0FXV2O1TXPX10
Requirements class: Type II
Version:
Photovoltaics, Combiner Box, 1000 V, 1 MPP, 3 Inputs / 3 Outputs per MPP, Surge protection II, Switch disconnector, WM4C
Delivery status:
This article will no longer be available in the future.
Additional text:
PVN DC 3IN/3OUTx1 1MPPT SW SPD2R WM4 1kV
 
Order No.: 2683310000
Amount of Maximum Power Points: 1 MPP
Connection type String: Internal terminal (with cable gland feed-through)
Type: PVN1M1I3SXFXV2O0TXPX10
Requirements class: Type II
Version:
Photovoltaics, Combiner Box, 1000 V, 1 MPP, 3 Inputs / 3 Outputs per MPP, Surge protection II, Cable gland
Delivery status:
This article will no longer be available in the future.
Additional text:
PVN DC 3IN/3OUTx1 1MPPT SPD2R CG 1kV
 
Order No.: 2683340000
Amount of Maximum Power Points: 1 MPP
Connection type String: Internal terminal (with cable gland feed-through)
Type: PVN1M1I3S0FXV2O0TXPX10
Requirements class: Type II
Version:
Photovoltaics, Combiner Box, 1000 V, 1 MPP, 3 Inputs / 3 Outputs per MPP, Surge protection II, Switch disconnector, Cable gland
Delivery status:
This article will no longer be available in the future.
Additional text:
PVN DC 3IN/3OUTx1 1MPPT SW SPD2R CG 1kV
 
Order No.: 2866360000
Amount of Maximum Power Points: 2 MPP
Connection type String: Plug MC4-Evo 2
Type: PVN DC 2IN/1OUTX2 2MPPT SPD1R EVO 1.1KV
Requirements class: Type I/II
Version:
Photovoltaics, Combiner Box, 1100 V, 2 MPP's, 2 Inputs / 1 Output per MPP, Surge protection I / II, MC4-Evo 2
 
Order No.: 2866320000
Amount of Maximum Power Points: 2 MPP
Connection type String: Internal terminal (with cable gland feed-through)
Type: PVN DC 2IN/1OUTX2 2MPPT SPD1R CG 1.1KV
Requirements class: Type I/II
Version:
Photovoltaics, Combiner Box, 1100 V, 2 MPP's, 2 Inputs / 1 Output per MPP, Surge protection I / II, Cable gland
 
Order No.: 2866350000
Amount of Maximum Power Points: 2 MPP
Connection type String: Plug WM4C
Type: PVN DC 2IN/1OUTX2 2MPPT SPD2R WM4C 1.1KV
Requirements class: Type II
Version:
Photovoltaics, Combiner Box, 1100 V, 2 MPP's, 2 Inputs / 1 Output per MPP, Surge protection II, WM4C
 
Order No.: 2866370000
Amount of Maximum Power Points: 2 MPP
Connection type String: Plug MC4-Evo 2
Type: PVN DC 2IN/1OUTX2 2MPPT SPD2R EVO 1.1KV
Requirements class: Type II
Version:
Photovoltaics, Combiner Box, 1100 V, 2 MPP's, 2 Inputs / 1 Output per MPP, Surge protection II, MC4-Evo 2
 
Order No.: 2866330000
Amount of Maximum Power Points: 2 MPP
Connection type String: Internal terminal (with cable gland feed-through)
Type: PVN DC 2IN/1OUTX2 2MPPT SPD2R CG 1.1KV
Requirements class: Type II
Version:
Photovoltaics, Combiner Box, 1100 V, 2 MPP's, 2 Inputs / 1 Output per MPP, Surge protection II, Cable gland
 
Order No.: 2737580000
Amount of Maximum Power Points: 2 MPP
Connection type String: Plug WM4C
Type: PVN1M2I4SXFXV1O1TXPX10
Requirements class: Type I/II
Version:
Photovoltaics, Combiner Box, 1000 V, 2 MPP's, 2 Inputs / 1 Output per MPP, Surge protection I / II, WM4C
Delivery status:
This article will no longer be available in the future.
Additional text:
PVN DC 2IN/1OUTx2 2MPPT SPD1R WM4 1kV
 
Order No.: 2737590000
Amount of Maximum Power Points: 2 MPP
Connection type String: Internal terminal (with cable gland feed-through)
Type: PVN1M2I4SXFXV1O0TXPX10
Requirements class: Type I/II
Version:
Photovoltaics, Combiner Box, 1000 V, 2 MPP's, 2 Inputs / 1 Output per MPP, Surge protection I / II, Cable gland
Delivery status:
This article will no longer be available in the future.
Additional text:
PVN DC 2IN/1OUTx2 2MPPT SPD1R CG 1kV
 
Order No.: 2791860000
Amount of Maximum Power Points: 2 MPP
Connection type String: Plug WM4C
Type: PVN1M2I4SXFXV2O1TXPX10
Requirements class: Type II
Version:
Photovoltaics, Combiner Box, 1000 V, 2 MPP's, 2 Inputs / 1 Output per MPP, Surge protection II, WM4C
Delivery status:
This article will no longer be available in the future.
Additional text:
PVN DC 2IN/1OUTx2 2MPPT SPD2R WM4 1kV
 
Order No.: 2791870000
Amount of Maximum Power Points: 2 MPP
Connection type String: Internal terminal (with cable gland feed-through)
Type: PVN1M2I4SXFXV2O0TXPX10
Requirements class: Type II
Version:
Photovoltaics, Combiner Box, 1000 V, 2 MPP's, 2 Inputs / 1 Output per MPP, Surge protection II, Cable gland
Delivery status:
This article will no longer be available in the future.
Additional text:
PVN DC 2IN/1OUTx2 2MPPT SPD2R CG 1kV
 
Order No.: 2683180000
Amount of Maximum Power Points: 2 MPP
Connection type String: Plug WM4C
Type: PVN1M2I6SXFXV1O1TXPX10
Requirements class: Type I/II
Version:
Photovoltaics, Combiner Box, 1000 V, 2 MPP's, 3 Inputs / 3 Outputs per MPP, Surge protection I / II, WM4C
Delivery status:
This article will no longer be available in the future.
Additional text:
PVN DC 3IN/3OUTx2 2MPPT SPD1R WM4 1kV
 
Order No.: 2683210000
Amount of Maximum Power Points: 2 MPP
Connection type String: Plug WM4C
Type: PVN1M2I6S0FXV1O1TXPX10
Requirements class: Type I/II
Version:
Photovoltaics, Combiner Box, 1000 V, 2 MPP's, 3 Inputs / 3 Outputs per MPP, Surge protection I / II, Switch disconnector, WM4C
Delivery status:
This article will no longer be available in the future.
Additional text:
PVN DC 3IN/3OUTx2 2MPPT SW SPD1R WM4 1kV
 
Order No.: 2683120000
Amount of Maximum Power Points: 2 MPP
Connection type String: Internal terminal (with cable gland feed-through)
Type: PVN1M2I6SXFXV1O0TXPX10
Requirements class: Type I/II
Version:
Photovoltaics, Combiner Box, 1000 V, 2 MPP's, 3 Inputs / 3 Outputs per MPP, Surge protection I / II, Cable gland
Delivery status:
This article will no longer be available in the future.
Additional text:
PVN DC 3IN/3OUTx2 2MPPT SPD1R CG 1kV
 
Order No.: 2683150000
Amount of Maximum Power Points: 2 MPP
Connection type String: Internal terminal (with cable gland feed-through)
Type: PVN1M2I6S0FXV1O0TXPX10
Requirements class: Type I/II
Version:
Photovoltaics, Combiner Box, 1000 V, 2 MPP's, 3 Inputs / 3 Outputs per MPP, Surge protection I / II, Switch disconnector, Cable gland
Delivery status:
This article will no longer be available in the future.
Additional text:
PVN DC 3IN/3OUTx2 2MPPT SW SPD1R CG 1kV
 
Order No.: 2683380000
Amount of Maximum Power Points: 2 MPP
Connection type String: Plug WM4C
Type: PVN1M2I6SXFXV2O1TXPX10
Requirements class: Type II
Version:
Photovoltaics, Combiner Box, 1000 V, 2 MPP's, 3 Inputs / 3 Outputs per MPP, Surge protection II, WM4C
Delivery status:
This article will no longer be available in the future.
Additional text:
PVN DC 3IN/3OUTx2 2MPPT SPD2R WM4 1kV
 
Order No.: 2683410000
Amount of Maximum Power Points: 2 MPP
Connection type String: Plug WM4C
Type: PVN1M2I6S0FXV2O1TXPX10
Requirements class: Type II
Version:
Photovoltaics, Combiner Box, 1000 V, 2 MPP's, 3 Inputs / 3 Outputs per MPP, Surge protection II, Switch disconnector, WM4C
Delivery status:
This article will no longer be available in the future.
Additional text:
PVN DC 3IN/3OUTx2 2MPPT SW SPD2R WM4 1kV
 
Order No.: 2683320000
Amount of Maximum Power Points: 2 MPP
Connection type String: Internal terminal (with cable gland feed-through)
Type: PVN1M2I6SXFXV2O0TXPX10
Requirements class: Type II
Version:
Photovoltaics, Combiner Box, 1000 V, 2 MPP's, 3 Inputs / 3 Outputs per MPP, Surge protection II, Cable gland
Delivery status:
This article will no longer be available in the future.
Additional text:
PVN DC 3IN/3OUTx2 2MPPT SPD2R CG 1kV
 
Order No.: 2683350000
Amount of Maximum Power Points: 2 MPP
Connection type String: Internal terminal (with cable gland feed-through)
Type: PVN1M2I6S0FXV2O0TXPX10
Requirements class: Type II
Version:
Photovoltaics, Combiner Box, 1000 V, 2 MPP's, 3 Inputs / 3 Outputs per MPP, Surge protection II, Switch disconnector, Cable gland
Delivery status:
This article will no longer be available in the future.
Additional text:
PVN DC 3IN/3OUTx2 2MPPT SW SPD2R CG 1kV
 
Order No.: 2683190000
Amount of Maximum Power Points: 3 MPP
Connection type String: Plug WM4C
Type: PVN1M3I9SXFXV1O1TXPX10
Requirements class: Type I/II
Version:
Photovoltaics, Combiner Box, 1000 V, 3 MPP's, 3 Inputs / 3 Outputs per MPP, Surge protection I / II, WM4C
Additional text:
PVN DC 3IN/3OUTx3 3MPPT SPD1R WM4 1kV
 
Order No.: 2683220000
Amount of Maximum Power Points: 3 MPP
Connection type String: Plug WM4C
Type: PVN1M3I9S0FXV1O1TXPX10
Requirements class: Type I/II
Version:
Photovoltaics, Combiner Box, 1000 V, 3 MPP's, 3 Inputs / 3 Outputs per MPP, Surge protection I / II, Switch disconnector, WM4C
Additional text:
PVN DC 3IN/3OUTx3 3MPPT SW SPD1R WM4 1kV
 
Order No.: 2683130000
Amount of Maximum Power Points: 3 MPP
Connection type String: Internal terminal (with cable gland feed-through)
Type: PVN1M3I9SXFXV1O0TXPX10
Requirements class: Type I/II
Version:
Photovoltaics, Combiner Box, 1000 V, 3 MPP's, 3 Inputs / 3 Outputs per MPP, Surge protection I / II, Cable gland
Additional text:
PVN DC 3IN/3OUTx3 3MPPT SPD1R CG 1kV
 
Order No.: 2683160000
Amount of Maximum Power Points: 3 MPP
Connection type String: Internal terminal (with cable gland feed-through)
Type: PVN1M3I9S0FXV1O0TXPX10
Requirements class: Type I/II
Version:
Photovoltaics, Combiner Box, 1000 V, 3 MPP's, 3 Inputs / 3 Outputs per MPP, Surge protection I / II, Switch disconnector, Cable gland
Additional text:
PVN DC 3IN/3OUTx3 3MPPT SW SPD1R CG 1kV
 
Order No.: 2683390000
Amount of Maximum Power Points: 3 MPP
Connection type String: Plug WM4C
Type: PVN1M3I9SXFXV2O1TXPX10
Requirements class: Type II
Version:
Photovoltaics, Combiner Box, 1000 V, 3 MPP's, 3 Inputs / 3 Outputs per MPP, Surge protection II, WM4C
Additional text:
PVN DC 3IN/3OUTx3 3MPPT SPD2R WM4 1kV
 
Order No.: 2683420000
Amount of Maximum Power Points: 3 MPP
Connection type String: Plug WM4C
Type: PVN1M3I9S0FXV2O1TXPX10
Requirements class: Type II
Version:
Photovoltaics, Combiner Box, 1000 V, 3 MPP's, 3 Inputs / 3 Outputs per MPP, Surge protection II, Switch disconnector, WM4C
Additional text:
PVN DC 3IN/3OUTx3 3MPPT SW SPD2R WM4 1kV
 
Order No.: 2683330000
Amount of Maximum Power Points: 3 MPP
Connection type String: Internal terminal (with cable gland feed-through)
Type: PVN1M3I9SXFXV2O0TXPX10
Requirements class: Type II
Version:
Photovoltaics, Combiner Box, 1000 V, 3 MPP's, 3 Inputs / 3 Outputs per MPP, Surge protection II, Cable gland
Additional text:
PVN DC 3IN/3OUTx3 3MPPT SPD2R CG 1kV
 
Order No.: 2683360000
Amount of Maximum Power Points: 3 MPP
Connection type String: Internal terminal (with cable gland feed-through)
Type: PVN1M3I9S0FXV2O0TXPX10
Requirements class: Type II
Version:
Photovoltaics, Combiner Box, 1000 V, 3 MPP's, 3 Inputs / 3 Outputs per MPP, Surge protection II, Switch disconnector, Cable gland
Additional text:
PVN DC 3IN/3OUTx3 3MPPT SW SPD2R CG 1kV
 
Order No.: 2737600000
Amount of Maximum Power Points: 4 MPP
Connection type String: Plug WM4C
Type: PVN1M4I4SXFXV1O1TXPX10
Requirements class: Type I/II
Version:
Photovoltaics, Combiner Box, 1000 V, 4 MPP´s, 2 Inputs / 1 Output per MPP, Surge protection I / II, WM4C
Additional text:
PVN DC 2IN/1OUTx4 4MPPT SPD1R WM4 1kV
 
Order No.: 2737610000
Amount of Maximum Power Points: 4 MPP
Connection type String: Internal terminal (with cable gland feed-through)
Type: PVN1M4I4SXFXV1O0TXPX10
Requirements class: Type I/II
Version:
Photovoltaics, Combiner Box, 1000 V, 4 MPP´s, 2 Inputs / 1 Output per MPP, Surge protection I / II, Cable gland
Additional text:
PVN DC 2IN/1OUTx4 4MPPT SPD1R CG 1kV
 
Order No.: 2791880000
Amount of Maximum Power Points: 4 MPP
Connection type String: Plug WM4C
Type: PVN1M4I8SXFXV2O1TXPX10
Requirements class: Type II
Version:
Photovoltaics, Combiner Box, 1000 V, 4 MPP´s, 2 Inputs / 1 Output per MPP, Surge protection II, WM4C
Additional text:
PVN DC 2IN/1OUTx4 4MPPT SPD2R WM4 1kV
 
Order No.: 2791890000
Amount of Maximum Power Points: 4 MPP
Connection type String: Internal terminal (with cable gland feed-through)
Type: PVN1M4I8SXFXV2O0TXPX10
Requirements class: Type II
Version:
Photovoltaics, Combiner Box, 1000 V, 4 MPP´s, 2 Inputs / 1 Output per MPP, Surge protection II, Cable gland
Additional text:
PVN DC 2IN/1OUTx4 4MPPT SPD2R CG 1kV
 
Order No.: 2737620000
Amount of Maximum Power Points: 6 MPP
Connection type String: Plug WM4C
Type: PVN1M6I4SXFXV1O1TXPX10
Requirements class: Type I/II
Version:
Photovoltaics, Combiner Box, 1000 V, 6 MPP´s, 2 Inputs / 1 Output per MPP, Surge protection I / II, WM4C
Additional text:
PVN DC 2IN/1OUTx6 6MPPT SPD1R WM4 1kV
 
Order No.: 2737630000
Amount of Maximum Power Points: 6 MPP
Connection type String: Internal terminal (with cable gland feed-through)
Type: PVN1M6I4SXFXV1O0TXPX10
Requirements class: Type I/II
Version:
Photovoltaics, Combiner Box, 1000 V, 6 MPP´s, 2 Inputs / 1 Output per MPP, Surge protection I / II, Cable gland
Additional text:
PVN DC 2IN/1OUTx6 6MPPT SPD1R CG 1kV
 
Order No.: 2791900000
Amount of Maximum Power Points: 6 MPP
Connection type String: Plug WM4C
Type: PVN1M6I12SXFXV2O1TXPX10
Requirements class: Type II
Version:
Photovoltaics, Combiner Box, 1000 V, 6 MPP´s, 2 Inputs / 1 Output per MPP, Surge protection II, WM4C
Additional text:
PVN DC 2IN/1OUTx6 6MPPT SPD2R WM4 1kV
 
Order No.: 2791910000
Amount of Maximum Power Points: 6 MPP
Connection type String: Internal terminal (with cable gland feed-through)
Type: PVN1M6I12SXFXV2O0TXPX10
Requirements class: Type II
Version:
Photovoltaics, Combiner Box, 1000 V, 6 MPP´s, 2 Inputs / 1 Output per MPP, Surge protection II, Cable gland
Additional text:
PVN DC 2IN/1OUTx6 6MPPT SPD2R CG 1kV
 
Order No.: 8000106274
Amount of Maximum Power Points: 10 MPP
Connection type String: Plug MC4-Evo 2
Type: PVC DC 2I 1O 10MPP SPD1R EVO 11
Requirements class: Type I/II
Version:
Photovoltaics, Combiner Box, 1100 V, 10 MPP's, 2 Inputs / 1 Output per MPP, Surge protection I / II, MC4-Evo 2
Additional text:
0063501200
 
Order No.: 8000107559
Amount of Maximum Power Points: 10 MPP
Connection type String: Plug MC4-Evo 2
Type: PVC DC 2I 2O 10MPP SPD1R EVO 11
Requirements class: Type I/II
Version:
Photovoltaics, Combiner Box, 1100 V, 10 MPP's, 2 Inputs / 2 Outputs per MPP, Surge protection I / II, MC4-Evo 2
Additional text:
0063501200
 
Order No.: 8000107558
Amount of Maximum Power Points: 12 MPP
Connection type String: Plug MC4-Evo 2
Type: PVC DC 2I 1O 12MPP SPD1R EVO 11
Requirements class: Type I/II
Version:
Photovoltaics, Combiner Box, 1100 V, 12 MPP's, 2 Inputs / 1 Output per MPP, Surge protection I / II, MC4-Evo 2
Additional text:
0063501200
 
Contact
Weidmüller Interface GmbH & Co. KG
 
+49 5231 14-0
+49 5231 14-292083
More information
Decentralised automation solutions
Energy Management Solutions
Industrial Analytics
Industrial IoT Solutions
More information
Mobility Concepts
Photovoltaics
Wind Solutions
Workplace Solutions
More information
Single Pair Ethernet
Weidmüller Configurator
Support & Service
Contact
Disposal Instructions
Engineering data
Repairs and replacement parts