Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Isolating amplifier and measuring transducer
Power Supplies
Electronics Housings
Lightning and Surge Protection
Photovoltaics
e-mobility
Fieldbus Distributors
SPDs for energy systems
SPDs for instrumentation and control (I&C)
SPDs for data interfaces
Miniature Circuit Breaker
Accessories
AC voltage
Photovoltaics
DIN rail TS 35
40mm busbars
Type I
Type II
Type III
VPU Type I Series
VPU Type II Series
230 V / 400 V
230 V / 400 V with integrated fuse
400 V / 690 V
950 V
Spare arrester
Optical status indicator
Optical status indicator & remote alert
Spare arrester
General ordering data
Version
Surge voltage arrester, Low voltage, Surge protection
Order No.
2859350000
Type
VPU AC I F 0 275/25
GTIN (EAN)
4064675570578
Qty.
1 pc(s).
Dimensions and weights
Depth
80 mm
Depth (inches)
3.15 inch
Height
45 mm
Height (inches)
1.772 inch
Width
36 mm
Width (inches)
1.417 inch
Net weight
198 g
Temperatures
Storage temperature
-40 °C...85 °C
Operating temperature
-40 °C...85 °C
Humidity
5 - 95% rel. humidity
Environmental Product Compliance
RoHS Compliance Status
Compliant without exemption
REACH SVHC
No SVHC above 0.1 wt%
General data
Number of poles
1
Protection degree
IP20 in installed state
Colour
orange
Rated data IEC / EN
Discharge current Imax (8/20µs) wire-PE
65 kA
Discharge current In (8/20µs) wire-PE
25 kA
Energy coordination (≤10 m)
Type I, Type II, Type III
Frequency range, max.
60 Hz
Frequency range, min.
50 Hz
Fuse
Not required, internally available
Lightning test current Iimp (10/350 µs) (L-PE)
25 kA
Mains voltage
230 V / 400 V
Max. continuous voltage, Uc (AC)
275 V
Number of poles
1
Rated voltage (AC)
240 V
Requirements category acc. to IEC 61643-11
Type I, Type II
Requirements class, acc. to EN 61643-11
T1, T2
Response time
<100 ns
Short-circuit current rating ISCCR
75 kA
Standards
EN 61643-11, IEC 61643-11
Suitable for
Count-in installation (leakage current free)
Temporary surge voltage (over-voltage) - TOV
442 V
Voltage type
AC
Connection data
Wire connection method
Plug-in connection
Electrical data
Voltage type
AC
Important note
Product information
If F1 > 315A gG, then the integrated backup fuse always operates before F1
Notes
Additional tests for 100kA Isccr have been passed without certification.
Classifications
ETIM 6.0
EC000941
ETIM 7.0
EC000941
ETIM 8.0
EC000941
ETIM 9.0
EC000941
ECLASS 9.0
27-13-08-05
ECLASS 9.1
27-13-08-05
ECLASS 10.0
27-13-08-05
ECLASS 11.0
27-13-08-05
ECLASS 12.0
27-17-90-90
ECLASS 13.0
27-17-90-90
ECLASS 14.0
27-17-90-90
Approvals
Approvals
ROHS
Conform
Order No.:
3056190000
Type:
VPU AC I F 0 275/25 MP
Version:
Surge protection
Order No.:
3022930000
Type:
VPU AC I F 0 N-PE 275/25
Version:
Surge protection
Version
Surge voltage arrester, Low voltage, Surge protection
Order No.
2859350000
Type
VPU AC I F 0 275/25
GTIN (EAN)
4064675570578
Qty.
1 pc(s).
Depth
80 mm
Depth (inches)
3.15 inch
Height
45 mm
Height (inches)
1.772 inch
Width
36 mm
Width (inches)
1.417 inch
Net weight
198 g
Storage temperature
-40 °C...85 °C
Operating temperature
-40 °C...85 °C
Humidity
5 - 95% rel. humidity
RoHS Compliance Status
Compliant without exemption
REACH SVHC
No SVHC above 0.1 wt%
Number of poles
1
Protection degree
IP20 in installed state
Colour
orange
Discharge current Imax (8/20µs) wire-PE
65 kA
Discharge current In (8/20µs) wire-PE
25 kA
Energy coordination (≤10 m)
Type I, Type II, Type III
Frequency range, max.
60 Hz
Frequency range, min.
50 Hz
Fuse
Not required, internally available
Lightning test current Iimp (10/350 µs) (L-PE)
25 kA
Mains voltage
230 V / 400 V
Max. continuous voltage, Uc (AC)
275 V
Number of poles
1
Rated voltage (AC)
240 V
Requirements category acc. to IEC 61643-11
Type I, Type II
Requirements class, acc. to EN 61643-11
T1, T2
Response time
<100 ns
Short-circuit current rating ISCCR
75 kA
Standards
EN 61643-11, IEC 61643-11
Suitable for
Count-in installation (leakage current free)
Temporary surge voltage (over-voltage) - TOV
442 V
Voltage type
AC
Wire connection method
Plug-in connection
Product information
If F1 > 315A gG, then the integrated backup fuse always operates before F1
Notes
Additional tests for 100kA Isccr have been passed without certification.
ETIM 6.0
EC000941
ETIM 7.0
EC000941
ETIM 8.0
EC000941
ETIM 9.0
EC000941
ECLASS 9.0
27-13-08-05
ECLASS 9.1
27-13-08-05
ECLASS 10.0
27-13-08-05
ECLASS 11.0
27-13-08-05
ECLASS 12.0
27-17-90-90
ECLASS 13.0
27-17-90-90
ECLASS 14.0
27-17-90-90
Approvals
ROHS
Conform
Order No.:
3056190000
Type:
VPU AC I F 0 275/25 MP
Version:
Surge protection
Order No.:
3022930000
Type:
VPU AC I F 0 N-PE 275/25
Version:
Surge protection
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.