Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Analogue Signal Conditioning
Power Supplies
Electronics Housings
Lightning and Surge Protection
e-mobility
Photovoltaics
Fieldbus Distributors
SPDs for energy systems
SPDs for instrumentation and control (I&C)
SPDs for data interfaces
Accessories
AC voltage
Photovoltaics
DIN rail TS 35
40mm busbars
Type I
Type II
Type III
VPU Type I Series
VPU Type II Series
230 V / 400 V
230 V / 400 V with integrated fuse
400 V / 690 V
950 V
Spare arrester
Optical status indicator
Optical status indicator & remote alert
Spare arrester
General ordering data
Version
Surge voltage arrester, Low voltage, Surge protection, TT nur für L-N, TN-C, TN-S
Order No.
2859340000
Type
VPU AC I F 1 R 275/25
GTIN (EAN)
4064675570516
Qty.
1 pc(s).
Dimensions and weights
Depth
91 mm
Depth (inches)
3.583 inch
Height
104.5 mm
Height (inches)
4.114 inch
Width
36 mm
Width (inches)
1.417 inch
Net weight
339 g
Temperatures
Storage temperature
-40 °C...85 °C
Operating temperature
-40 °C...85 °C
Humidity
5 - 95% rel. humidity
Environmental Product Compliance
REACH SVHC
/
General data
Colour
black, orange
Design
Installation housing; 2TE, Insta IP 20
Operating altitude
≤ 2000 m
Optical function display
green = OK; red = arrester is defective - replace
Protection degree
IP20 in installed state
Rail
TS 35
Segment
Power distribution
Suitable for
Count-in installation (leakage current free)
UL 94 flammability rating
V-0
Version
Surge protection
Insulation coordination acc. to EN 50178
Pollution severity
2
Surge voltage category
IV
Rated data IEC / EN
Discharge current Imax (8/20µs) wire-PE
65 kA
Discharge current In (8/20µs) wire-PE
25 kA
Discharge current, Iimp (10/350 µs)
25 kA
Energy coordination (≤10 m)
Type I, Type II, Type III
Frequency range, max.
60 Hz
Frequency range, min.
50 Hz
Fuse
Not required
Lightning test current Iimp (10/350 µs) (L-PE)
25 kA
Low voltage network
TT nur für L-N, TN-C, TN-S
Mains voltage
230 V / 400 V
Max. continuous voltage, Uc (AC)
275 V
Number of poles
1
Protection level Up at IN (L/N-PE)
≤ 1.5 kV
Rated voltage (AC)
240 V
Requirements category acc. to IEC 61643-11
Type I, Type II
Requirements class, acc. to EN 61643-11
T1, T2
Response time
<100 ns
Short-circuit current rating ISCCR
100 kA
Signalling contact
250 V 1A 1CO
Standards
EN 61643-11, IEC 61643-11
Suitable for
Count-in installation (leakage current free)
Temporary surge voltage (over-voltage) - TOV
442 V
Voltage type
AC
Connection data
Stripping length
15 mm
Wire connection method
Screw connection
Type of connection
Screw connection
Stripping length, rated connection
15 mm
Tightening torque, min.
2.5 Nm
Tightening torque, max.
4.5 Nm
Clamping range, rated connection
16 mm²
Clamping range, min.
4 mm²
Clamping range, max.
35 mm²
Wire cross-section, solid, min.
1.5 mm²
Wire cross-section, solid, max.
35 mm²
Wire connection cross section, finely stranded, min.
1.5 mm²
Wire connection cross section, finely stranded, max.
25 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.
2.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.
35 mm²
Connection cross-section, stranded, min.
1.5 mm²
Connection cross-section, stranded, max.
35 mm²
Guarantee
Time interval
5 years
Important note
Product information
If F1 > 315A gG, then the integrated backup fuse always operates before F1
Downloads
Approval/Certificate/Document of Conformity
Engineering Data
User Documentation
Catalogues
Catalogues in PDF-format
Classifications
ETIM 6.0
EC000941
ETIM 7.0
EC000941
ETIM 8.0
EC000941
ETIM 9.0
EC000941
ECLASS 9.0
27-13-08-05
ECLASS 9.1
27-13-08-05
ECLASS 10.0
27-13-08-05
ECLASS 11.0
27-13-08-05
ECLASS 12.0
27-17-90-90
ECLASS 13.0
27-17-90-90
Approvals
Approvals
ROHS
Conform
Version
Surge voltage arrester, Low voltage, Surge protection, TT nur für L-N, TN-C, TN-S
Order No.
2859340000
Type
VPU AC I F 1 R 275/25
GTIN (EAN)
4064675570516
Qty.
1 pc(s).
Depth
91 mm
Depth (inches)
3.583 inch
Height
104.5 mm
Height (inches)
4.114 inch
Width
36 mm
Width (inches)
1.417 inch
Net weight
339 g
Storage temperature
-40 °C...85 °C
Operating temperature
-40 °C...85 °C
Humidity
5 - 95% rel. humidity
Colour
black, orange
Design
Installation housing; 2TE, Insta IP 20
Operating altitude
≤ 2000 m
Optical function display
green = OK; red = arrester is defective - replace
Protection degree
IP20 in installed state
Rail
TS 35
Segment
Power distribution
Suitable for
Count-in installation (leakage current free)
UL 94 flammability rating
V-0
Version
Surge protection
Pollution severity
2
Surge voltage category
IV
Discharge current Imax (8/20µs) wire-PE
65 kA
Discharge current In (8/20µs) wire-PE
25 kA
Discharge current, Iimp (10/350 µs)
25 kA
Energy coordination (≤10 m)
Type I, Type II, Type III
Frequency range, max.
60 Hz
Frequency range, min.
50 Hz
Fuse
Not required
Lightning test current Iimp (10/350 µs) (L-PE)
25 kA
Low voltage network
TT nur für L-N, TN-C, TN-S
Mains voltage
230 V / 400 V
Max. continuous voltage, Uc (AC)
275 V
Number of poles
1
Protection level Up at IN (L/N-PE)
≤ 1.5 kV
Rated voltage (AC)
240 V
Requirements category acc. to IEC 61643-11
Type I, Type II
Requirements class, acc. to EN 61643-11
T1, T2
Response time
<100 ns
Short-circuit current rating ISCCR
100 kA
Signalling contact
250 V 1A 1CO
Standards
EN 61643-11, IEC 61643-11
Suitable for
Count-in installation (leakage current free)
Temporary surge voltage (over-voltage) - TOV
442 V
Voltage type
AC
Stripping length
15 mm
Wire connection method
Screw connection
Type of connection
Screw connection
Stripping length, rated connection
15 mm
Tightening torque, min.
2.5 Nm
Tightening torque, max.
4.5 Nm
Clamping range, rated connection
16 mm²
Clamping range, min.
4 mm²
Clamping range, max.
35 mm²
Wire cross-section, solid, min.
1.5 mm²
Wire cross-section, solid, max.
35 mm²
Wire connection cross section, finely stranded, min.
1.5 mm²
Wire connection cross section, finely stranded, max.
25 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.
2.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.
35 mm²
Connection cross-section, stranded, min.
1.5 mm²
Connection cross-section, stranded, max.
35 mm²
Product information
If F1 > 315A gG, then the integrated backup fuse always operates before F1
ETIM 6.0
EC000941
ETIM 7.0
EC000941
ETIM 8.0
EC000941
ETIM 9.0
EC000941
ECLASS 9.0
27-13-08-05
ECLASS 9.1
27-13-08-05
ECLASS 10.0
27-13-08-05
ECLASS 11.0
27-13-08-05
ECLASS 12.0
27-17-90-90
ECLASS 13.0
27-17-90-90
Approvals
ROHS
Conform
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.