AC voltage
Photovoltaics
VPU US series
VPU PV I + II
VPU PV II
VPU PV II MB
600 V
1000 V
1500 V
With remote alert
Without remote alert
Spare Arrester
General ordering data
Order No.
2857020000
Type
VPU PV II 5 R 1000
GTIN (EAN)
4064675537380
Qty.
1 pc(s).
Dimensions and weights
Depth
60 mm
Depth (inches)
2.362 inch
Height
105 mm
Height (inches)
4.134 inch
Width
90 mm
Width (inches)
3.543 inch
Mounting dimension - height
105 mm
Net weight
479 g
Temperatures
Storage temperature
85 °C
Operating temperature
-40 °C...85 °C
Humidity
5 - 95% rel. humidity
Environmental Product Compliance
RoHS Compliance Status
Compliant without exemption
REACH SVHC
No SVHC above 0.1 wt%
Rated data UL
Ambient temperature (operational), max.
85 °C
Rated Voltage UN
1,100 V
In
20 kA
Ambient temperature (operational), min.
-40 °C
Voltage type
DC
Connection data, remote alert
Cross-section for connected wire, solid core, max.
1.5 mm²
Cross-section for connected wire, solid core, min.
0.14 mm²
Stripping length
8 mm
General data
Number of poles
5
Protection degree
IP20
Colour
grey
Insulation coordination acc. to EN 50178
Pollution severity
2
Surge voltage category
III
Photovoltaic technical data
Discharge current In (8/20 µs)
20 kA
Discharge current, max. (8/20 µs)
40 kA
Operating height in the grounded PV system
≤ 2000 m
Operating height in ungrounded PV system
≤ 2000 m
PV system voltage, max. Ucpv
1,100 V
Protection level Up (+/- , -/PE , +/PE)
≤4,2 kV
Requirements class
Type II
Short-circuit curent ISCPV
11,000 A
Standards
IEC 61643-31, EN 61643-31
Total discharge current Itotal ( 8/20µs)
40 kA
Rated data IEC / EN
Discharge current Imax (8/20µs) wire-PE
40 kA
Discharge current, max. (8/20 µs)
40 kA
Integrated back-up fuse
No
Leakage current at Un
30 µA
Number of poles
5
Rated voltage (DC)
1000 V
Response time
≤ 25 ns
SPD type
T2
Signalling contact
250 V 1A 1CO
Standards
IEC 61643-31, EN 61643-31
Voltage type
DC
Connection data
Stripping length
18 mm
Type of connection
Screw connection
Stripping length, rated connection
18 mm
Tightening torque, min.
3 Nm
Tightening torque, max.
4.5 Nm
Clamping range, rated connection
6 mm²
Clamping range, min.
1.5 mm²
Clamping range, max.
35 mm²
Wire cross-section, solid, min.
1.5 mm²
Wire cross-section, solid, max.
16 mm²
Wire connection cross section, finely stranded, min.
1.5 mm²
Wire connection cross section, finely stranded, max.
25 mm²
Connection cross-section, stranded, min.
1.5 mm²
Connection cross-section, stranded, max.
35 mm²
Electrical data
Voltage type
DC
Classifications
ETIM 6.0
EC000941
ETIM 7.0
EC000941
ETIM 8.0
EC000941
ETIM 9.0
EC000941
ETIM 10.0
EC000941
ECLASS 9.1
27-13-08-05
ECLASS 10.0
27-13-08-05
ECLASS 11.0
27-13-08-05
ECLASS 12.0
27-17-90-90
ECLASS 13.0
27-17-90-90
ECLASS 14.0
27-17-90-90
ECLASS 15.0
27-17-90-90
Approvals
Approvals
ROHS
Conform
Order No.:
2530180000
Type of connection:
Screw connection
Type:
VPU PV II 3 R 1000
Version:
Surge voltage arrester, Low voltage, with remote contact
Order No.
2857020000
Type
VPU PV II 5 R 1000
GTIN (EAN)
4064675537380
Qty.
1 pc(s).
Depth
60 mm
Depth (inches)
2.362 inch
Height
105 mm
Height (inches)
4.134 inch
Width
90 mm
Width (inches)
3.543 inch
Mounting dimension - height
105 mm
Net weight
479 g
Storage temperature
85 °C
Operating temperature
-40 °C...85 °C
Humidity
5 - 95% rel. humidity
RoHS Compliance Status
Compliant without exemption
REACH SVHC
No SVHC above 0.1 wt%
Ambient temperature (operational), max.
85 °C
Rated Voltage UN
1,100 V
In
20 kA
Ambient temperature (operational), min.
-40 °C
Voltage type
DC
Cross-section for connected wire, solid core, max.
1.5 mm²
Cross-section for connected wire, solid core, min.
0.14 mm²
Stripping length
8 mm
Number of poles
5
Protection degree
IP20
Colour
grey
Pollution severity
2
Surge voltage category
III
Discharge current In (8/20 µs)
20 kA
Discharge current, max. (8/20 µs)
40 kA
Operating height in the grounded PV system
≤ 2000 m
Operating height in ungrounded PV system
≤ 2000 m
PV system voltage, max. Ucpv
1,100 V
Protection level Up (+/- , -/PE , +/PE)
≤4,2 kV
Requirements class
Type II
Short-circuit curent ISCPV
11,000 A
Standards
IEC 61643-31, EN 61643-31
Total discharge current Itotal ( 8/20µs)
40 kA
Discharge current Imax (8/20µs) wire-PE
40 kA
Discharge current, max. (8/20 µs)
40 kA
Integrated back-up fuse
No
Leakage current at Un
30 µA
Number of poles
5
Rated voltage (DC)
1000 V
Response time
≤ 25 ns
SPD type
T2
Signalling contact
250 V 1A 1CO
Standards
IEC 61643-31, EN 61643-31
Voltage type
DC
Stripping length
18 mm
Type of connection
Screw connection
Stripping length, rated connection
18 mm
Tightening torque, min.
3 Nm
Tightening torque, max.
4.5 Nm
Clamping range, rated connection
6 mm²
Clamping range, min.
1.5 mm²
Clamping range, max.
35 mm²
Wire cross-section, solid, min.
1.5 mm²
Wire cross-section, solid, max.
16 mm²
Wire connection cross section, finely stranded, min.
1.5 mm²
Wire connection cross section, finely stranded, max.
25 mm²
Connection cross-section, stranded, min.
1.5 mm²
Connection cross-section, stranded, max.
35 mm²
ETIM 6.0
EC000941
ETIM 7.0
EC000941
ETIM 8.0
EC000941
ETIM 9.0
EC000941
ETIM 10.0
EC000941
ECLASS 9.1
27-13-08-05
ECLASS 10.0
27-13-08-05
ECLASS 11.0
27-13-08-05
ECLASS 12.0
27-17-90-90
ECLASS 13.0
27-17-90-90
ECLASS 14.0
27-17-90-90
ECLASS 15.0
27-17-90-90
Approvals
ROHS
Conform
Order No.:
2530180000
Type of connection:
Screw connection
Type:
VPU PV II 3 R 1000
Version:
Surge voltage arrester, Low voltage, with remote contact
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.
Did you know?
We have a new product catalog.
Try it now!
One moment...
You will be redirected to our new product catalog.
Don't forget: Add the new product catalog to your bookmarks!