Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Analogue Signal Conditioning
Power Supplies
Electronic Housings
Lightning and Surge Protection
e-mobility
Photovoltaics
Fieldbus Distributors
SPDs for energy systems
SPDs for instrumentation and control (I&C)
SPDs for data interfaces
Accessories
AC voltage
Photovoltaics
40mm busbars
DIN rail TS 35
Type I
Type II
Type III
Typ I: 230/400V; 400/690V
Typ II Series; 230/400 V; 1000 V; Spare Arrester VPU II
230 V / 400 V
230 V / 400 V with integrated fuse
VPU I 280 V LCF 25 kA MB
400 V / 690 V
950 V
Spare arrester
VPU AC I 3+MOV R 950/12.5
General ordering data
Version
Surge voltage arrester, Low voltage, Surge protection, with remote contact, TN-C, IT without N
Order No.
2845570000
Type
VPU AC I 3+MOV R 950/12.5
GTIN (EAN)
4064675453499
Qty.
1 pc(s).
Dimensions and weights
Depth
91 mm
Depth (inches)
3.583 inch
Height
96.3 mm
Height (inches)
3.791 inch
Width
54 mm
Width (inches)
2.126 inch
Net weight
780 g
Temperatures
Storage temperature
-40 °C...85 °C
Operating temperature
-40 °C...85 °C
Operating temperature, min.
-40 °C
Operating temperature, max.
85 °C
Humidity
5 - 95% rel. humidity
Connection data, remote alert
Connection type
PUSH IN
Cross-section for connected wire, solid core, max.
1.5 mm²
Cross-section for connected wire, solid core, min.
0.14 mm²
Stripping length
8 mm
General data
Colour
orange, black
Design
Installation housing; 3TE
Operating altitude
≤ 2000 m
Optical function display
green = OK; red = arrester is defective - replace
Protection degree
IP20 in installed state
Rail
TS 35
Segment
Power distribution
UL 94 flammability rating
V-0
Version
Surge protection, with remote contact
Insulation coordination acc. to EN 50178
Pollution severity
2
Surge voltage category
IV
Rated data IEC / EN
Discharge current Imax (8/20µs) wire-PE
50 kA
Discharge current In (8/20µs) wire-PE
20 kA
Energy coordination (≤10 m)
Type I, Type II, Type III
Follow-on current extinguishing capability Ifi
25 kA
Frequency range, max.
60 Hz
Frequency range, min.
50 Hz
Fuse
160 A gG
Leakage current at Un
0.6 mA
Lightning test current Iimp (10/350 µs) (L-PE)
12.5 kA
Low voltage network
TN-C, IT without N
Max. continuous voltage, Uc (AC)
950 V
Max. continuous voltage, Uc (N-PE)
950 V
Number of poles
3
Protection level Up at IN (L/N-PE)
≤ 4 kV
Rated voltage (AC)
800 V
Requirements category acc. to IEC 61643-11
Type I/II
Requirements class, acc. to EN 61643-11
T1, T2
Response time
≤ 25 ns
Short-circuit current rating ISCCR
25 kA
Signalling contact
250 V 1 A 1 NC
Standards
IEC61643-11, EN61643-11
Voltage type
AC
Connection data
Stripping length
13 mm
Wire connection method
Screw connection
Type of connection
Screw connection
Stripping length, rated connection
15 mm
Tightening torque, min.
2 Nm
Tightening torque, max.
3 Nm
Clamping range, rated connection
16 mm²
Clamping range, min.
6 mm²
Clamping range, max.
35 mm²
Wire cross-section, solid, min.
2.5 mm²
Wire cross-section, solid, max.
35 mm²
Wire connection cross section, finely stranded, min.
2.5 mm²
Wire connection cross section, finely stranded, max.
35 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.
6 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.
35 mm²
Connection cross-section, stranded, min.
2.5 mm²
Connection cross-section, stranded, max.
35 mm²
Guarantee
Time interval
5 years
Classifications
ETIM 6.0
EC000941
ETIM 7.0
EC000941
ETIM 8.0
EC000941
ETIM 9.0
EC000941
ECLASS 9.0
27-13-08-05
ECLASS 9.1
27-13-08-05
ECLASS 10.0
27-13-08-05
ECLASS 11.0
27-13-08-05
ECLASS 12.0
27-17-90-90
ECLASS 13.0
27179090
Approvals
Approvals
ROHS
Conform
There are no products in this group.
Version
Surge voltage arrester, Low voltage, Surge protection, with remote contact, TN-C, IT without N
Order No.
2845570000
Type
VPU AC I 3+MOV R 950/12.5
GTIN (EAN)
4064675453499
Qty.
1 pc(s).
Depth
91 mm
Depth (inches)
3.583 inch
Height
96.3 mm
Height (inches)
3.791 inch
Width
54 mm
Width (inches)
2.126 inch
Net weight
780 g
Storage temperature
-40 °C...85 °C
Operating temperature
-40 °C...85 °C
Operating temperature, min.
-40 °C
Operating temperature, max.
85 °C
Humidity
5 - 95% rel. humidity
Connection type
PUSH IN
Cross-section for connected wire, solid core, max.
1.5 mm²
Cross-section for connected wire, solid core, min.
0.14 mm²
Stripping length
8 mm
Colour
orange, black
Design
Installation housing; 3TE
Operating altitude
≤ 2000 m
Optical function display
green = OK; red = arrester is defective - replace
Protection degree
IP20 in installed state
Rail
TS 35
Segment
Power distribution
UL 94 flammability rating
V-0
Version
Surge protection, with remote contact
Pollution severity
2
Surge voltage category
IV
Discharge current Imax (8/20µs) wire-PE
50 kA
Discharge current In (8/20µs) wire-PE
20 kA
Energy coordination (≤10 m)
Type I, Type II, Type III
Follow-on current extinguishing capability Ifi
25 kA
Frequency range, max.
60 Hz
Frequency range, min.
50 Hz
Fuse
160 A gG
Leakage current at Un
0.6 mA
Lightning test current Iimp (10/350 µs) (L-PE)
12.5 kA
Low voltage network
TN-C, IT without N
Max. continuous voltage, Uc (AC)
950 V
Max. continuous voltage, Uc (N-PE)
950 V
Number of poles
3
Protection level Up at IN (L/N-PE)
≤ 4 kV
Rated voltage (AC)
800 V
Requirements category acc. to IEC 61643-11
Type I/II
Requirements class, acc. to EN 61643-11
T1, T2
Response time
≤ 25 ns
Short-circuit current rating ISCCR
25 kA
Signalling contact
250 V 1 A 1 NC
Standards
IEC61643-11, EN61643-11
Voltage type
AC
Stripping length
13 mm
Wire connection method
Screw connection
Type of connection
Screw connection
Stripping length, rated connection
15 mm
Tightening torque, min.
2 Nm
Tightening torque, max.
3 Nm
Clamping range, rated connection
16 mm²
Clamping range, min.
6 mm²
Clamping range, max.
35 mm²
Wire cross-section, solid, min.
2.5 mm²
Wire cross-section, solid, max.
35 mm²
Wire connection cross section, finely stranded, min.
2.5 mm²
Wire connection cross section, finely stranded, max.
35 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.
6 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.
35 mm²
Connection cross-section, stranded, min.
2.5 mm²
Connection cross-section, stranded, max.
35 mm²
ETIM 6.0
EC000941
ETIM 7.0
EC000941
ETIM 8.0
EC000941
ETIM 9.0
EC000941
ECLASS 9.0
27-13-08-05
ECLASS 9.1
27-13-08-05
ECLASS 10.0
27-13-08-05
ECLASS 11.0
27-13-08-05
ECLASS 12.0
27-17-90-90
ECLASS 13.0
27179090
Approvals
ROHS
Conform
There are no products in this group.
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.