Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Isolating amplifier and measuring transducer
Power Supplies
Electronics Housings
Lightning and Surge Protection
e-mobility
Photovoltaics
Fieldbus Distributors
SPDs for energy systems
SPDs for instrumentation and control (I&C)
SPDs for data interfaces
Miniature Circuit Breaker
Accessories
AC voltage
Photovoltaics
DIN rail TS 35
40mm busbars
60mm busbars
Type I
Type II
Type III
VPU Type I Series
VPU Type II Series
VPU AC II
VPU AC II+III S
VPU AC II US series
VPU AC II F with integrated fuse
230/400V IoT
230 V / 400 V
Spare arrester
Optical status indicator
Optical status indicator & remote alert
General ordering data
Version
Surge voltage arrester, Low voltage, Class II surge protection, no leakage current, Single-phase, TN-S
Order No.
2827590000
Type
VPU AC II F 2 300/40
GTIN (EAN)
4064675366584
Qty.
1 pc(s).
Dimensions and weights
Depth
68 mm
Depth (inches)
2.677 inch
Depth including DIN rail
76 mm
Height
90 mm
Height (inches)
3.543 inch
Width
36 mm
Width (inches)
1.417 inch
Net weight
268 g
Temperatures
Storage temperature
-40 °C...85 °C
Operating temperature
-40 °C...85 °C
Humidity
5 - 95% rel. humidity
Environmental Product Compliance
RoHS Compliance Status
Compliant without exemption
REACH SVHC
No SVHC above 0.1 wt%
General data
Number of poles
1
Protection degree
IP20 in installed state
Colour
orange, black
Insulation coordination acc. to EN 50178
Pollution severity
2
Surge voltage category
III
Rated data IEC / EN
Combined pulse UOC
6 kV
Discharge current Imax (8/20µs) wire-PE
40 kA
Discharge current In (8/20µs) wire-PE
20 kA
Energy coordination (≤10 m)
Type II, Type III
Follow-on current extinguishing capability Ifi
Follow current need not be taken into account
Frequency range, max.
60 Hz
Frequency range, min.
50 Hz
Fuse
Not required, internally available
Leakage current at Un
0.4 mA
Low voltage network
Single-phase, TN-S
Mains voltage
230 V / 400 V
Max. continuous voltage, Uc (AC)
300 V
Number of poles
1
Protection level Up at IN (L/N-PE)
≤ 1.5 kV
Rated voltage (AC)
230 V
Requirements category acc. to IEC 61643-11
Type II, Type III
Requirements class, acc. to EN 61643-11
T2, T3
Response time
≤ 25 ns
SPD type
T2, T3
Short-circuit current rating ISCCR
100 kA
Signalling contact
No
Standards
IEC 61643-11, EN 61643-11
Temporary surge voltage (over-voltage) - TOV
337 V
Voltage type
AC
Connection data
Stripping length
18 mm
Wire connection method
Screw connection
Type of connection
Screw connection
Stripping length, rated connection
18 mm
Tightening torque, min.
3 Nm
Tightening torque, max.
4.5 Nm
Clamping range, rated connection
16 mm²
Clamping range, min.
1.5 mm²
Clamping range, max.
35 mm²
Wire cross-section, solid, min.
2.5 mm²
Wire cross-section, solid, max.
35 mm²
Wire connection cross section, finely stranded, min.
1.5 mm²
Wire connection cross section, finely stranded, max.
35 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.
2.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.
25 mm²
Connection cross-section, stranded, min.
1.5 mm²
Connection cross-section, stranded, max.
25 mm²
Electrical data
Voltage type
AC
Guarantee
Time interval
5 years
Important note
Product information
If F1 > 63A gG, then the integrated backup fuse always operates before F1
Classifications
ETIM 6.0
EC000941
ETIM 7.0
EC000941
ETIM 8.0
EC000941
ETIM 9.0
EC000941
ECLASS 9.0
27-13-08-05
ECLASS 9.1
27-13-08-05
ECLASS 10.0
27-13-08-05
ECLASS 11.0
27-13-08-05
ECLASS 12.0
27-17-90-90
ECLASS 13.0
27-17-90-90
ECLASS 14.0
27-17-90-90
Approvals
Approvals
ROHS
Conform
Type of connection:
Screw connection
Order No.:
2827580000
Type:
VPU AC II F 1 300/40
Version:
Surge voltage arrester, Low voltage, Class II surge protection, no leakage current, Single-phase, TN
Type of connection:
Screw connection
Order No.:
2827620000
Type:
VPU AC II F 1+1 300/40
Version:
Surge voltage arrester, Low voltage, Overvoltage protection for low-voltage supply, Single-phase, TN, TT, IT with N, IT without N
Type of connection:
Screw connection
Order No.:
2827600000
Type:
VPU AC II F 3 300/40
Version:
Surge voltage arrester, Low voltage, Class II surge protection, no leakage current, TN-C
Type of connection:
Screw connection
Order No.:
2827630000
Type:
VPU AC II F 3+1 300/40
Version:
Surge voltage arrester, Low voltage, Class II surge protection, no leakage current, TN-C-S, TN-S, TT, IT with N, IT without N
Type of connection:
Screw connection
Order No.:
2827610000
Type:
VPU AC II F 4 300/40
Version:
Surge voltage arrester, Low voltage, Class II surge protection, no leakage current, TN-S
Version
Surge voltage arrester, Low voltage, Class II surge protection, no leakage current, Single-phase, TN-S
Order No.
2827590000
Type
VPU AC II F 2 300/40
GTIN (EAN)
4064675366584
Qty.
1 pc(s).
Depth
68 mm
Depth (inches)
2.677 inch
Depth including DIN rail
76 mm
Height
90 mm
Height (inches)
3.543 inch
Width
36 mm
Width (inches)
1.417 inch
Net weight
268 g
Storage temperature
-40 °C...85 °C
Operating temperature
-40 °C...85 °C
Humidity
5 - 95% rel. humidity
RoHS Compliance Status
Compliant without exemption
REACH SVHC
No SVHC above 0.1 wt%
Number of poles
1
Protection degree
IP20 in installed state
Colour
orange, black
Pollution severity
2
Surge voltage category
III
Combined pulse UOC
6 kV
Discharge current Imax (8/20µs) wire-PE
40 kA
Discharge current In (8/20µs) wire-PE
20 kA
Energy coordination (≤10 m)
Type II, Type III
Follow-on current extinguishing capability Ifi
Follow current need not be taken into account
Frequency range, max.
60 Hz
Frequency range, min.
50 Hz
Fuse
Not required, internally available
Leakage current at Un
0.4 mA
Low voltage network
Single-phase, TN-S
Mains voltage
230 V / 400 V
Max. continuous voltage, Uc (AC)
300 V
Number of poles
1
Protection level Up at IN (L/N-PE)
≤ 1.5 kV
Rated voltage (AC)
230 V
Requirements category acc. to IEC 61643-11
Type II, Type III
Requirements class, acc. to EN 61643-11
T2, T3
Response time
≤ 25 ns
SPD type
T2, T3
Short-circuit current rating ISCCR
100 kA
Signalling contact
No
Standards
IEC 61643-11, EN 61643-11
Temporary surge voltage (over-voltage) - TOV
337 V
Voltage type
AC
Stripping length
18 mm
Wire connection method
Screw connection
Type of connection
Screw connection
Stripping length, rated connection
18 mm
Tightening torque, min.
3 Nm
Tightening torque, max.
4.5 Nm
Clamping range, rated connection
16 mm²
Clamping range, min.
1.5 mm²
Clamping range, max.
35 mm²
Wire cross-section, solid, min.
2.5 mm²
Wire cross-section, solid, max.
35 mm²
Wire connection cross section, finely stranded, min.
1.5 mm²
Wire connection cross section, finely stranded, max.
35 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.
2.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.
25 mm²
Connection cross-section, stranded, min.
1.5 mm²
Connection cross-section, stranded, max.
25 mm²
Product information
If F1 > 63A gG, then the integrated backup fuse always operates before F1
ETIM 6.0
EC000941
ETIM 7.0
EC000941
ETIM 8.0
EC000941
ETIM 9.0
EC000941
ECLASS 9.0
27-13-08-05
ECLASS 9.1
27-13-08-05
ECLASS 10.0
27-13-08-05
ECLASS 11.0
27-13-08-05
ECLASS 12.0
27-17-90-90
ECLASS 13.0
27-17-90-90
ECLASS 14.0
27-17-90-90
Approvals
ROHS
Conform
Type of connection:
Screw connection
Order No.:
2827580000
Type:
VPU AC II F 1 300/40
Version:
Surge voltage arrester, Low voltage, Class II surge protection, no leakage current, Single-phase, TN
Type of connection:
Screw connection
Order No.:
2827620000
Type:
VPU AC II F 1+1 300/40
Version:
Surge voltage arrester, Low voltage, Overvoltage protection for low-voltage supply, Single-phase, TN, TT, IT with N, IT without N
Type of connection:
Screw connection
Order No.:
2827600000
Type:
VPU AC II F 3 300/40
Version:
Surge voltage arrester, Low voltage, Class II surge protection, no leakage current, TN-C
Type of connection:
Screw connection
Order No.:
2827630000
Type:
VPU AC II F 3+1 300/40
Version:
Surge voltage arrester, Low voltage, Class II surge protection, no leakage current, TN-C-S, TN-S, TT, IT with N, IT without N
Type of connection:
Screw connection
Order No.:
2827610000
Type:
VPU AC II F 4 300/40
Version:
Surge voltage arrester, Low voltage, Class II surge protection, no leakage current, TN-S
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.