Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Isolating amplifier and measuring transducer
Power Supplies
Electronics Housings
Lightning and Surge Protection
e-mobility
Photovoltaics
Fieldbus Distributors
SPDs for energy systems
SPDs for instrumentation and control (I&C)
SPDs for data interfaces
Miniature Circuit Breaker
Accessories
AC voltage
Photovoltaics
DIN rail TS 35
40mm busbars
60mm busbars
Type I
Type II
Type III
VPU Type I Series
VPU Type II Series
VPU AC II
VPU AC II+III S
VPU AC II US series
VPU AC II F with integrated fuse
230/400V IoT
230 V / 400 V
Spare arrester
VPU AC II F 0 N-PE 305/65
General ordering data
Version
Surge voltage arrester, Low voltage, Class II surge protection, no leakage current, TT only for N-PE
Order No.
2807540000
Type
VPU AC II F 0 N-PE 305/65
GTIN (EAN)
4064675275558
Qty.
1 pc(s).
Dimensions and weights
Depth
64 mm
Depth (inches)
2.52 inch
Height
45 mm
Height (inches)
1.772 inch
Width
18 mm
Width (inches)
0.709 inch
Net weight
42 g
Temperatures
Storage temperature
-40 °C...85 °C
Operating temperature
-40 °C...85 °C
Humidity
5 - 95% rel. humidity
Environmental Product Compliance
RoHS Compliance Status
Compliant without exemption
REACH SVHC
No SVHC above 0.1 wt%
General data
Number of poles
1
Protection degree
IP20 in installed state
Colour
blue
Insulation coordination acc. to EN 50178
Pollution severity
2
Surge voltage category
III
Rated data IEC / EN
Combined pulse UOC
6 kV
Discharge current Imax (8/20µs) N-PE
65 kA
Discharge current In (8/20µs) N-PE
40 kA
Discharge current In (8/20µs) wire-PE
20 kA
Energy coordination (≤10 m)
Type II, Type III
Follow-on current extinguishing capability Ifi
Follow current need not be taken into account
Frequency range, max.
60 Hz
Frequency range, min.
50 Hz
Fuse
Not required
Leakage current at Un
5 µA
Low voltage network
TT only for N-PE
Mains voltage
230 V / 400 V
Max. continuous voltage, Uc (AC)
305 V
Max. continuous voltage, Uc (N-PE)
305 V
Number of poles
1
Protection level Up at IN (N-PE)
≤ 1.5 kV
Requirements category acc. to IEC 61643-11
Type II, Type III
Requirements class, acc. to EN 61643-11
T2, T3
Response time
≤ 100 ns
SPD type
T2, T3
Short-circuit current rating ISCCR
100 kA
Standards
IEC61643-11, EN61643-11
Temporary surge voltage (over-voltage) - TOV
1,200 V
Voltage type
AC
Electrical data
Voltage type
AC
Guarantee
Time interval
5 years
Important note
Product information
If F1 > 63A gG, then the integrated backup fuse always operates before F1
Classifications
ETIM 6.0
EC000941
ETIM 7.0
EC000941
ETIM 8.0
EC000941
ETIM 9.0
EC000941
ECLASS 9.0
27-13-08-05
ECLASS 9.1
27-13-08-05
ECLASS 10.0
27-13-08-05
ECLASS 11.0
27-13-08-05
ECLASS 12.0
27-17-90-90
ECLASS 13.0
27-17-90-90
ECLASS 14.0
27-17-90-90
Approvals
Approvals
ROHS
Conform
Order No.:
2807520000
Type:
VPU AC II F 0 300/40
Version:
Surge voltage arrester, Low voltage, Class II surge protection, no leakage current
Version
Surge voltage arrester, Low voltage, Class II surge protection, no leakage current, TT only for N-PE
Order No.
2807540000
Type
VPU AC II F 0 N-PE 305/65
GTIN (EAN)
4064675275558
Qty.
1 pc(s).
Depth
64 mm
Depth (inches)
2.52 inch
Height
45 mm
Height (inches)
1.772 inch
Width
18 mm
Width (inches)
0.709 inch
Net weight
42 g
Storage temperature
-40 °C...85 °C
Operating temperature
-40 °C...85 °C
Humidity
5 - 95% rel. humidity
RoHS Compliance Status
Compliant without exemption
REACH SVHC
No SVHC above 0.1 wt%
Number of poles
1
Protection degree
IP20 in installed state
Colour
blue
Pollution severity
2
Surge voltage category
III
Combined pulse UOC
6 kV
Discharge current Imax (8/20µs) N-PE
65 kA
Discharge current In (8/20µs) N-PE
40 kA
Discharge current In (8/20µs) wire-PE
20 kA
Energy coordination (≤10 m)
Type II, Type III
Follow-on current extinguishing capability Ifi
Follow current need not be taken into account
Frequency range, max.
60 Hz
Frequency range, min.
50 Hz
Fuse
Not required
Leakage current at Un
5 µA
Low voltage network
TT only for N-PE
Mains voltage
230 V / 400 V
Max. continuous voltage, Uc (AC)
305 V
Max. continuous voltage, Uc (N-PE)
305 V
Number of poles
1
Protection level Up at IN (N-PE)
≤ 1.5 kV
Requirements category acc. to IEC 61643-11
Type II, Type III
Requirements class, acc. to EN 61643-11
T2, T3
Response time
≤ 100 ns
SPD type
T2, T3
Short-circuit current rating ISCCR
100 kA
Standards
IEC61643-11, EN61643-11
Temporary surge voltage (over-voltage) - TOV
1,200 V
Voltage type
AC
Product information
If F1 > 63A gG, then the integrated backup fuse always operates before F1
ETIM 6.0
EC000941
ETIM 7.0
EC000941
ETIM 8.0
EC000941
ETIM 9.0
EC000941
ECLASS 9.0
27-13-08-05
ECLASS 9.1
27-13-08-05
ECLASS 10.0
27-13-08-05
ECLASS 11.0
27-13-08-05
ECLASS 12.0
27-17-90-90
ECLASS 13.0
27-17-90-90
ECLASS 14.0
27-17-90-90
Approvals
ROHS
Conform
Order No.:
2807520000
Type:
VPU AC II F 0 300/40
Version:
Surge voltage arrester, Low voltage, Class II surge protection, no leakage current
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.