Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Isolating amplifier and measuring transducer
Power Supplies
Electronics Housings
Lightning and Surge Protection
e-mobility
Photovoltaics
Fieldbus Distributors
Residential and commercial combiner boxes
Utility scale combiner boxes
Connectors
Switch boxes
String monitoring
Accessories
DC generator combiner boxes without fuses
DC generator combiner boxes with fuses
Fireman Switch
PV Inline
AC Boxes
PV PROTECT
Standalone PCBA's
PVN PCBA 1KV 2X2I1O SPD T1+2 NF
General ordering data
Version
Photovoltaics, PCB, Combiner Box, 2 MPP's, 2 Inputs / 1 Output per MPP, Surge protection I / II, 1000 V, 15 A
Order No.
2770510000
Type
PVN PCBA 1KV 2X2I1O SPD T1+2 NF
GTIN (EAN)
4064675029595
Qty.
1 pc(s).
Delivery status
This article will no longer be available in the future.
Available until
2024-12-31
Dimensions and weights
Depth
254 mm
Depth (inches)
10 inch
Height
87.1 mm
Height (inches)
3.429 inch
Width
145 mm
Width (inches)
5.709 inch
Net weight
950 g
Environmental Product Compliance
RoHS Compliance Status
Compliant
REACH SVHC
Lead 7439-92-1
SCIP
bdab5698-6a20-4370-8e28-8810d882d01a
Electrical characteristics
Current per Maximum Power Point, max.
30 A
Rated DC voltage
1,000 V
Rated short-term current resistance
Enclosure
Type of mounting
4 screws
General data
Protection degree
IP00
Standards
EN 61439-2:2011, IEC 61439-2 ed 2.0
Inputs
Amount of maximum power points (MPP)
2
DC Input + & -
Wire connection
Type of connection
PUSH IN with actuator
Compatible cable crossection
TÜV 2 Pfg1169/08.07, EN 50618:2015
Wire cross-section, min.
2.5 mm²
Wire cross-section, max.
16 mm²
Fuse type
Neither fuse cartridge nor holder
Max. number of DC inputs
per Maximum Power Point 2 inputs connected in parallel
Number of string inputs per MPP
≤ 2
Surge protection auxiliary contact
Wire connection
Type of connection
Tension clamp connection with actuator
Flexible, max. H05(07) V-K
1.5 mm²
w. wire end ferrule, DIN 46228 pt 1, max.
1.5 mm²
Outputs
DC Output + & -
Wire connection
Compatible cable crossection
TÜV 2 Pfg1169/08.07, EN 50618:2015
Wire cross-section, min.
2.5 mm²
Wire cross-section, max.
16 mm²
Max. number of DC outputs
per Maximum Power Point 1 output
Surge protection DC side
Discharge current In (8/20 µs)
20 kA
Discharge current, max. (8/20 µs)
40 kA
Lightning test current Iimp (10/350 µs)
6.25 kA
PV system voltage, max. Ucpv
1,100 V
Protection level Up (+/- , -/PE , +/PE)
≤ 3.8 kV
Protection level Up (+/-)
≤ 3.8 kV
Protection level Up (+/PE)
≤ 3.8 kV
Protection level Up (-/PE)
≤ 3.8 kV
Requirements class
Type I/II
Short-circuit curent ISCPV
11,000 A
Standards
EN 61439-2:2011, IEC 61439-2 ed 2.0
Standby power consumption PC
< 0.2 W
Total discharge current Itotal ( 8/20µs)
50
Total discharge current Itotal (10/350µs)
12.5 kA
Classifications
ETIM 6.0
EC002928
ETIM 7.0
EC002928
ETIM 8.0
EC003857
ETIM 9.0
EC003857
ECLASS 9.0
22-57-92-03
ECLASS 9.1
22-57-02-90
ECLASS 10.0
22-57-02-90
ECLASS 11.0
22-57-02-92
ECLASS 12.0
22-57-02-92
ECLASS 13.0
22-57-02-92
ECLASS 14.0
22-57-02-92
Approvals
Approvals
ROHS
Conform
Version
Photovoltaics, PCB, Combiner Box, 2 MPP's, 2 Inputs / 1 Output per MPP, Surge protection I / II, 1000 V, 15 A
Order No.
2770510000
Type
PVN PCBA 1KV 2X2I1O SPD T1+2 NF
GTIN (EAN)
4064675029595
Qty.
1 pc(s).
Delivery status
This article will no longer be available in the future.
Available until
2024-12-31
Depth
254 mm
Depth (inches)
10 inch
Height
87.1 mm
Height (inches)
3.429 inch
Width
145 mm
Width (inches)
5.709 inch
Net weight
950 g
RoHS Compliance Status
Compliant
REACH SVHC
Lead 7439-92-1
SCIP
bdab5698-6a20-4370-8e28-8810d882d01a
Current per Maximum Power Point, max.
30 A
Rated DC voltage
1,000 V
Rated short-term current resistance
Type of mounting
4 screws
Protection degree
IP00
Standards
EN 61439-2:2011, IEC 61439-2 ed 2.0
Amount of maximum power points (MPP)
2
DC Input + & -
Wire connection
Type of connection
PUSH IN with actuator
Compatible cable crossection
TÜV 2 Pfg1169/08.07, EN 50618:2015
Wire cross-section, min.
2.5 mm²
Wire cross-section, max.
16 mm²
Fuse type
Neither fuse cartridge nor holder
Max. number of DC inputs
per Maximum Power Point 2 inputs connected in parallel
Number of string inputs per MPP
≤ 2
Surge protection auxiliary contact
Wire connection
Type of connection
Tension clamp connection with actuator
Flexible, max. H05(07) V-K
1.5 mm²
w. wire end ferrule, DIN 46228 pt 1, max.
1.5 mm²
DC Output + & -
Wire connection
Compatible cable crossection
TÜV 2 Pfg1169/08.07, EN 50618:2015
Wire cross-section, min.
2.5 mm²
Wire cross-section, max.
16 mm²
Max. number of DC outputs
per Maximum Power Point 1 output
Discharge current In (8/20 µs)
20 kA
Discharge current, max. (8/20 µs)
40 kA
Lightning test current Iimp (10/350 µs)
6.25 kA
PV system voltage, max. Ucpv
1,100 V
Protection level Up (+/- , -/PE , +/PE)
≤ 3.8 kV
Protection level Up (+/-)
≤ 3.8 kV
Protection level Up (+/PE)
≤ 3.8 kV
Protection level Up (-/PE)
≤ 3.8 kV
Requirements class
Type I/II
Short-circuit curent ISCPV
11,000 A
Standards
EN 61439-2:2011, IEC 61439-2 ed 2.0
Standby power consumption PC
< 0.2 W
Total discharge current Itotal ( 8/20µs)
50
Total discharge current Itotal (10/350µs)
12.5 kA
ETIM 6.0
EC002928
ETIM 7.0
EC002928
ETIM 8.0
EC003857
ETIM 9.0
EC003857
ECLASS 9.0
22-57-92-03
ECLASS 9.1
22-57-02-90
ECLASS 10.0
22-57-02-90
ECLASS 11.0
22-57-02-92
ECLASS 12.0
22-57-02-92
ECLASS 13.0
22-57-02-92
ECLASS 14.0
22-57-02-92
Approvals
ROHS
Conform
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.