Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Analogue Signal Conditioning
Power Supplies
Electronics Housings
Lightning and Surge Protection
e-mobility
Photovoltaics
Fieldbus Distributors
Switched-mode power supply units
Electronic load monitoring
Communication modules
Uninterruptible power supply
DC/DC converter
Diode- and redundancy modules
Pre charge unit
Decentralised switched-mode power supply units IP65
Decentralised electronic load monitoring IP65
Accessories
FieldPower® PROtop 3-phase with power bus
FieldPower® PROtop 3-phase with maxGUARD
FieldPower® PROtop 3-phase assembly kit
FieldPower® PROtop 1-phase assembly kit
General ordering data
Version
FieldPower® power supply unit, IP65, in complete state, 10A, 24 V, DC, IDC terminal, PUSH IN, M12, A-coded
Order No.
2743440000
Type
FP PRO TOP3 24/10 2P
GTIN (EAN)
4064675038375
Qty.
1 pc(s).
Dimensions and weights
Depth
220 mm
Depth (inches)
8.661 inch
Height
196 mm
Height (inches)
7.717 inch
Width
196 mm
Width (inches)
7.717 inch
Net weight
4,000 g
Temperatures
Storage temperature
-10 °C...60 °C
Operating temperature
-25 °C...50 °C
Operating temperature range
-25 °C ... +50 °C (regard derating) Start up ≥ -40 °C
Humidity
35…85%, non condensing and non freezing
Environmental Product Compliance
REACH SVHC
Lead 7439-92-1, Potassium perfluorobutane sulfonate 29420-49-3
SCIP
7645f3b1-6db9-495d-9e21-ab1d894aff05
Input
AC current consumption
0,7 A @ 400 V DC / 0,8 A @ 320 V AC
AC input voltage range
3 x 320...3 x 575 V AC / 2 x 360...2 x 575 V AC
DC input voltage range
450...800 V DC (max. 500 V DC acc. to UL508)
Frequency range AC
45…65 Hz
Recommended back-up fuse
2 - 3 A, Char. C
Surge protection
Varistor
Inrush current
Max. 10 A
Input fuse (internal)
3.0 A F (6.3 x 32 mm)
Output
Adjustable rated current
No
Output current
10A
Output power
240 W
Output voltage
24 V
Output voltage type
DC
Output voltage, max.
28.8 V
Output voltage, min.
22.5 V
Output voltage, note
(adjustable via potentiometer)
Switch-on delay
1 s
Triggering characteristic
see characteristic curve
Rated output voltage
24 V DC ± 1 %
Nominal output current for Unom
10 A @ 60 °C
General data
Humidity
35…85%, non condensing and non freezing
Installation advice
Lid screws included
Protection degree
IP65, in complete state
Short-circuit protection
Yes, internal
Standards
UL 508
Surge voltage category
III, II
Insulation coordination
Surge voltage category
III, II
Connection data (input)
Connection system
IDC terminal
Approbations
Certificate no. (cULus)
E258476
Institute (cULus)
CULUS
Clamping capacity
Connection data - contact element power bus
Wire connection method
Insulation displacement connection (IDC)
Blade size of operating tool
0.6 x 3.5 mm
Number of poles
5
Conductor connection cross-section, solid, max.
6 mm²
Conductor connection cross-section, solid, min.
1.5 mm²
Conductor connection cross-section, stranded, max.
6 mm²
Conductor connection cross-section, stranded, min.
2.5 mm²
Conductor connection cross-section, finely stranded, max.
6 mm²
Conductor connection cross-section, finely stranded, min.
2.5 mm²
Conductor connection cross-section, finest stranded, max.
6 mm²
Conductor connection cross-section, finest stranded, min.
2.5 mm²
Connection data - contact element Branch / Feed-in
Wire connection method
PUSH IN
Blade size of operating tool
0.6 x 3.5 mm
Stripping length
14 mm
Number of poles
5
Conductor connection cross-section, solid, max.
6 mm²
Conductor connection cross-section, solid, min.
0.5 mm²
Conductor connection cross-section, stranded, max.
6 mm²
Conductor connection cross-section, stranded, min.
0.5 mm²
Conductor connection cross-section, finely stranded, max.
10 mm²
Conductor connection cross-section, finely stranded, min.
0.5 mm²
Conductor connection cross-section, finest stranded, max.
6 mm²
Conductor connection cross-section, finest stranded, min.
0.5 mm²
Conductor connection cross-section with wire end ferrule
Type of wire end ferrule
12 mm with plastic collar
Standard
DIN 46228/1
Cross-section, min.
0.5 mm²
Cross-section, max.
6 mm²
Type of wire end ferrule
12 mm with plastic collar
Standard
DIN 46228/4
Cross-section, min.
0.5 mm²
Cross-section, max.
6 mm²
Type of wire end ferrule
8 mm with plastic collar
Standard
DIN 46228/1
Cross-section, min.
0.5 mm²
Cross-section, max.
6 mm²
Type of wire end ferrule
8 mm with plastic collar
Standard
DIN 46228/4
Cross-section, min.
0.5 mm²
Cross-section, max.
6 mm²
Type of wire end ferrule
Twin wire-end ferrules
Cross-section, min.
0.5 mm²
Cross-section, max.
6 mm²
Rated data acc. to IEC
Rated data acc. to IEC for contact element
Voltage type
AC, DC
Standard
IEC 60947-7-1, IEC 60947-7-2
Rated voltage
800 V
Rated impulse withstand voltage
8 kV
Rated current (3 loaded poles)
41 A
Rated current (4 loaded poles)
25 A
Rated data acc. to IEC for fuse plug
Voltage type
AC
Number of phases
3
Standard
IEC 61984, IEC 60947-7-3
Rated voltage
36 V
Rated impulse withstand voltage
6 kV
Rated current
12 A
Rated data acc. to IEC for plug-in connector
Voltage type
DC
Standard
IEC 60947-7-1, IEC 60947-7-2, IEC 61984
Rated voltage
690 V
Rated impulse withstand voltage
8 kV
Rated current (3 loaded poles)
32 A
Rated current (4 loaded poles)
25 A
Rated data acc. to UL
Rated data acc. to UL for contact element
Standard
UL 1059
Note
for use with UL-listed TC-ER cables
Conductor connection cross-section, AWG, max.
AWG 10
Conductor connection cross-section, AWG, min.
AWG 14
Rated voltage
600 V
Rated current
30 A
Rated data acc. to UL for fuse plug
Rated data acc. to UL for plug-in connector
Standard
UL 1059
Note
for use with UL-listed TC-ER cables
Conductor connection cross-section, AWG, max.
AWG 12
Conductor connection cross-section, AWG, min.
AWG 16
Rated voltage
600 V
Rated current
20 A
Standards
UL 508
Downloads
Approval/Certificate/Document of Conformity
Engineering Data
CADENAS eCATALOG
CAX data
Product Change Notification
User Documentation
Catalogues
Catalogues in PDF-format
Classifications
ETIM 6.0
EC002540
ETIM 7.0
EC002540
ETIM 8.0
EC002540
ETIM 9.0
EC002540
ECLASS 9.1
27-04-07-01
ECLASS 10.0
27-04-07-01
ECLASS 11.0
27-04-07-01
ECLASS 12.0
27-04-07-01
ECLASS 13.0
27-04-90-02
Order No.:
2743450000
Type:
FP PRO TOP3 24/20 2P
Version:
FieldPower® power supply unit, IP65, in closed state, in complete state, 20A, 24 V, DC, IDC terminal, PUSH IN, M12, A-coded
Order No.:
2743460000
Type:
FP PRO TOP3 24/20 2PIOL
Version:
FieldPower® power supply unit, IP65, in closed state, in complete state, 20A, 24 V, DC, IDC terminal, PUSH IN, M12 A-coded (IO-Link)
Version
FieldPower® power supply unit, IP65, in complete state, 10A, 24 V, DC, IDC terminal, PUSH IN, M12, A-coded
Order No.
2743440000
Type
FP PRO TOP3 24/10 2P
GTIN (EAN)
4064675038375
Qty.
1 pc(s).
Depth
220 mm
Depth (inches)
8.661 inch
Height
196 mm
Height (inches)
7.717 inch
Width
196 mm
Width (inches)
7.717 inch
Net weight
4,000 g
Storage temperature
-10 °C...60 °C
Operating temperature
-25 °C...50 °C
Operating temperature range
-25 °C ... +50 °C (regard derating) Start up ≥ -40 °C
Humidity
35…85%, non condensing and non freezing
REACH SVHC
Lead 7439-92-1, Potassium perfluorobutane sulfonate 29420-49-3
SCIP
7645f3b1-6db9-495d-9e21-ab1d894aff05
AC current consumption
0,7 A @ 400 V DC / 0,8 A @ 320 V AC
AC input voltage range
3 x 320...3 x 575 V AC / 2 x 360...2 x 575 V AC
DC input voltage range
450...800 V DC (max. 500 V DC acc. to UL508)
Frequency range AC
45…65 Hz
Recommended back-up fuse
2 - 3 A, Char. C
Surge protection
Varistor
Inrush current
Max. 10 A
Input fuse (internal)
3.0 A F (6.3 x 32 mm)
Adjustable rated current
No
Output current
10A
Output power
240 W
Output voltage
24 V
Output voltage type
DC
Output voltage, max.
28.8 V
Output voltage, min.
22.5 V
Output voltage, note
(adjustable via potentiometer)
Switch-on delay
1 s
Triggering characteristic
see characteristic curve
Rated output voltage
24 V DC ± 1 %
Nominal output current for Unom
10 A @ 60 °C
Humidity
35…85%, non condensing and non freezing
Installation advice
Lid screws included
Protection degree
IP65, in complete state
Short-circuit protection
Yes, internal
Standards
UL 508
Surge voltage category
III, II
Surge voltage category
III, II
Connection system
IDC terminal
Certificate no. (cULus)
E258476
Institute (cULus)
CULUS
Connection data - contact element power bus
Wire connection method
Insulation displacement connection (IDC)
Blade size of operating tool
0.6 x 3.5 mm
Number of poles
5
Conductor connection cross-section, solid, max.
6 mm²
Conductor connection cross-section, solid, min.
1.5 mm²
Conductor connection cross-section, stranded, max.
6 mm²
Conductor connection cross-section, stranded, min.
2.5 mm²
Conductor connection cross-section, finely stranded, max.
6 mm²
Conductor connection cross-section, finely stranded, min.
2.5 mm²
Conductor connection cross-section, finest stranded, max.
6 mm²
Conductor connection cross-section, finest stranded, min.
2.5 mm²
Connection data - contact element Branch / Feed-in
Wire connection method
PUSH IN
Blade size of operating tool
0.6 x 3.5 mm
Stripping length
14 mm
Number of poles
5
Conductor connection cross-section, solid, max.
6 mm²
Conductor connection cross-section, solid, min.
0.5 mm²
Conductor connection cross-section, stranded, max.
6 mm²
Conductor connection cross-section, stranded, min.
0.5 mm²
Conductor connection cross-section, finely stranded, max.
10 mm²
Conductor connection cross-section, finely stranded, min.
0.5 mm²
Conductor connection cross-section, finest stranded, max.
6 mm²
Conductor connection cross-section, finest stranded, min.
0.5 mm²
Conductor connection cross-section with wire end ferrule
Type of wire end ferrule
12 mm with plastic collar
Standard
DIN 46228/1
Cross-section, min.
0.5 mm²
Cross-section, max.
6 mm²
Type of wire end ferrule
12 mm with plastic collar
Standard
DIN 46228/4
Cross-section, min.
0.5 mm²
Cross-section, max.
6 mm²
Type of wire end ferrule
8 mm with plastic collar
Standard
DIN 46228/1
Cross-section, min.
0.5 mm²
Cross-section, max.
6 mm²
Type of wire end ferrule
8 mm with plastic collar
Standard
DIN 46228/4
Cross-section, min.
0.5 mm²
Cross-section, max.
6 mm²
Type of wire end ferrule
Twin wire-end ferrules
Cross-section, min.
0.5 mm²
Cross-section, max.
6 mm²
Rated data acc. to IEC for contact element
Voltage type
AC, DC
Standard
IEC 60947-7-1, IEC 60947-7-2
Rated voltage
800 V
Rated impulse withstand voltage
8 kV
Rated current (3 loaded poles)
41 A
Rated current (4 loaded poles)
25 A
Rated data acc. to IEC for fuse plug
Voltage type
AC
Number of phases
3
Standard
IEC 61984, IEC 60947-7-3
Rated voltage
36 V
Rated impulse withstand voltage
6 kV
Rated current
12 A
Rated data acc. to IEC for plug-in connector
Voltage type
DC
Standard
IEC 60947-7-1, IEC 60947-7-2, IEC 61984
Rated voltage
690 V
Rated impulse withstand voltage
8 kV
Rated current (3 loaded poles)
32 A
Rated current (4 loaded poles)
25 A
Rated data acc. to UL for contact element
Standard
UL 1059
Note
for use with UL-listed TC-ER cables
Conductor connection cross-section, AWG, max.
AWG 10
Conductor connection cross-section, AWG, min.
AWG 14
Rated voltage
600 V
Rated current
30 A
Rated data acc. to UL for fuse plug
Rated data acc. to UL for plug-in connector
Standard
UL 1059
Note
for use with UL-listed TC-ER cables
Conductor connection cross-section, AWG, max.
AWG 12
Conductor connection cross-section, AWG, min.
AWG 16
Rated voltage
600 V
Rated current
20 A
Standards
UL 508
Approval/Certificate/Document of Conformity
Engineering Data
CADENAS eCATALOG
CAX data
Product Change Notification
User Documentation
Catalogues
Catalogues in PDF-format
ETIM 6.0
EC002540
ETIM 7.0
EC002540
ETIM 8.0
EC002540
ETIM 9.0
EC002540
ECLASS 9.1
27-04-07-01
ECLASS 10.0
27-04-07-01
ECLASS 11.0
27-04-07-01
ECLASS 12.0
27-04-07-01
ECLASS 13.0
27-04-90-02
Approvals
ROHS
Conform
UL File Number Search
UL Website
Certificate no. (cULus)
E258476
Order No.:
2743450000
Type:
FP PRO TOP3 24/20 2P
Version:
FieldPower® power supply unit, IP65, in closed state, in complete state, 20A, 24 V, DC, IDC terminal, PUSH IN, M12, A-coded
Order No.:
2743460000
Type:
FP PRO TOP3 24/20 2PIOL
Version:
FieldPower® power supply unit, IP65, in closed state, in complete state, 20A, 24 V, DC, IDC terminal, PUSH IN, M12 A-coded (IO-Link)
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.