Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Terminal Blocks
Connectors
PCB Terminals and Connectors
Enclosure Systems and Components
Contactless Connectivity
Cable Entry Systems and Components
Cord sets, Patchcords and Cables
PLC Interfaces and Migration Solutions
Service Interfaces
Distribution Boxes
Universal range
Application range
Terminal blocks for the direct lettering
Accessories
Power feed-in
Power distribution
Instrument transformer wiring
Control voltage distribution
Signal wiring
Signal marshalling
Shielding and earthing
Building installation wiring
PUSH IN technology
Tension clamp technology
Clamping yoke technology
Potential equalisation terminal block
Shield clamping saddle
Accessories
Protective earth terminal block for functional earth
2.5 mm²
4 mm²
6 mm²
10 mm²
General ordering data
Version
Feed-through terminal, PUSH IN, 4 mm², white
Order No.
2734150000
Type
A2C 4 FE WT
GTIN (EAN)
4050118814248
Qty.
50 pc(s).
Dimensions and weights
Depth
39.5 mm
Depth (inches)
1.555 inch
Height
60 mm
Height (inches)
2.362 inch
Width
6.1 mm
Width (inches)
0.24 inch
Net weight
12.357 g
Temperatures
Storage temperature
-25 °C...55 °C
Continuous operating temp., min.
-60 °C
Continuous operating temp., max.
130 °C
Environmental Product Compliance
REACH SVHC
/
RoHS Compliance Status
Compliant without exemption
Material data
Material
Wemid
Colour
white
UL 94 flammability rating
V-0
Rating data IECEx/ATEX
Certificate No. (ATEX)
TUEV16ATEX7909U
Certificate No. (IECEX)
IECEXTUR16.0036U
Max. voltage (ATEX)
550 V
Current (ATEX)
28 A
Wire cross section max. (ATEX)
4 mm²
Max. voltage (IECEX)
550 V
Current (IECEX)
28 A
Wire cross section max. (IECEX)
4 mm²
System specifications
End cover plate required
Yes
Number of potentials
1
Number of levels
1
Number of clamping points per level
2
Number of potentials per tier
1
Rail
TS 35
PE function
Yes
Additional technical data
Open sides
right
Snap-on
Yes
Type of fixing
Snap-on
Type of mounting
TS 35, TS 32
Conductors for clamping (additional connection)
Connection type, additional connection
PUSH IN
Conductors for clamping (rated connection)
Blade size
0.6 x 3.5 mm
Clamping range, max.
6 mm²
Clamping range, min.
0.14 mm²
Connection cross-section, stranded, max.
6 mm²
Connection cross-section, stranded, min.
0.5 mm²
Connection direction
top
Gauge to IEC 60947-1
A4
Number of connections
2
Stripping length
12 mm
Tube length for twin wire-end ferrule
Tube length
Cross-section for conductor connection
min.
0.5 mm²
max.
1.5 mm²
Tube length for wire-end ferrule with plastic collar DIN 46228/4
Cross-section for conductor connection
Tube length
Cross-section for conductor connection
min.
1.5 mm²
max.
2.5 mm²
Tube length
Cross-section for conductor connection
Tube length
Tube length for wire-end ferrule without plastic collar DIN 46228/1
Cross-section for conductor connection
Tube length
Cross-section for conductor connection
min.
1.5 mm²
max.
2.5 mm²
Tube length
Cross-section for conductor connection
Tube length
Twin wire-end ferrules, max.
1.5 mm²
Twin wire-end ferrules, min.
0.5 mm²
Type of connection
PUSH IN
Wire connection cross section AWG, max.
AWG 12
Wire connection cross section AWG, min.
AWG 26
Wire connection cross section, finely stranded, max.
6 mm²
Wire connection cross section, finely stranded, min.
0.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, max.
6 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, min.
0.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.
4 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.
0.5 mm²
Wire connection cross-section, solid core, max.
4 mm²
Wire connection cross-section, solid core, min.
0.5 mm²
General
Rail
TS 35
Standards
IEC 60947-7-2
Wire connection cross section AWG, max.
AWG 12
Wire connection cross section AWG, min.
AWG 26
Rating data
Rated cross-section
4 mm²
Rated voltage to adjoining terminal
800 V
Rated DC voltage
800 V
Standards
IEC 60947-7-2
Rated impulse withstand voltage
8 kV
Pollution severity
3
Surge voltage category
III
Classifications
ETIM 6.0
EC000901
ETIM 7.0
EC000901
ETIM 8.0
EC000901
ETIM 9.0
EC000901
ECLASS 9.0
27-14-11-41
ECLASS 9.1
27-14-11-41
ECLASS 10.0
27-14-11-41
ECLASS 11.0
27-14-11-41
ECLASS 12.0
27-14-11-41
ECLASS 13.0
27-25-01-03
ECLASS 14.0
27-25-01-03
There are no products in this group.
Version
Feed-through terminal, PUSH IN, 4 mm², white
Order No.
2734150000
Type
A2C 4 FE WT
GTIN (EAN)
4050118814248
Qty.
50 pc(s).
Depth
39.5 mm
Depth (inches)
1.555 inch
Height
60 mm
Height (inches)
2.362 inch
Width
6.1 mm
Width (inches)
0.24 inch
Net weight
12.357 g
Storage temperature
-25 °C...55 °C
Continuous operating temp., min.
-60 °C
Continuous operating temp., max.
130 °C
REACH SVHC
/
RoHS Compliance Status
Compliant without exemption
Material
Wemid
Colour
white
UL 94 flammability rating
V-0
Certificate No. (ATEX)
TUEV16ATEX7909U
Certificate No. (IECEX)
IECEXTUR16.0036U
Max. voltage (ATEX)
550 V
Current (ATEX)
28 A
Wire cross section max. (ATEX)
4 mm²
Max. voltage (IECEX)
550 V
Current (IECEX)
28 A
Wire cross section max. (IECEX)
4 mm²
End cover plate required
Yes
Number of potentials
1
Number of levels
1
Number of clamping points per level
2
Number of potentials per tier
1
Rail
TS 35
PE function
Yes
Open sides
right
Snap-on
Yes
Type of fixing
Snap-on
Type of mounting
TS 35, TS 32
Connection type, additional connection
PUSH IN
Blade size
0.6 x 3.5 mm
Clamping range, max.
6 mm²
Clamping range, min.
0.14 mm²
Connection cross-section, stranded, max.
6 mm²
Connection cross-section, stranded, min.
0.5 mm²
Connection direction
top
Gauge to IEC 60947-1
A4
Number of connections
2
Stripping length
12 mm
Tube length for twin wire-end ferrule
Tube length
Cross-section for conductor connection
min.
0.5 mm²
max.
1.5 mm²
Tube length for wire-end ferrule with plastic collar DIN 46228/4
Cross-section for conductor connection
Tube length
Cross-section for conductor connection
min.
1.5 mm²
max.
2.5 mm²
Tube length
Cross-section for conductor connection
Tube length
Tube length for wire-end ferrule without plastic collar DIN 46228/1
Cross-section for conductor connection
Tube length
Cross-section for conductor connection
min.
1.5 mm²
max.
2.5 mm²
Tube length
Cross-section for conductor connection
Tube length
Twin wire-end ferrules, max.
1.5 mm²
Twin wire-end ferrules, min.
0.5 mm²
Type of connection
PUSH IN
Wire connection cross section AWG, max.
AWG 12
Wire connection cross section AWG, min.
AWG 26
Wire connection cross section, finely stranded, max.
6 mm²
Wire connection cross section, finely stranded, min.
0.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, max.
6 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, min.
0.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.
4 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.
0.5 mm²
Wire connection cross-section, solid core, max.
4 mm²
Wire connection cross-section, solid core, min.
0.5 mm²
Rail
TS 35
Standards
IEC 60947-7-2
Wire connection cross section AWG, max.
AWG 12
Wire connection cross section AWG, min.
AWG 26
Rated cross-section
4 mm²
Rated voltage to adjoining terminal
800 V
Rated DC voltage
800 V
Standards
IEC 60947-7-2
Rated impulse withstand voltage
8 kV
Pollution severity
3
Surge voltage category
III
ETIM 6.0
EC000901
ETIM 7.0
EC000901
ETIM 8.0
EC000901
ETIM 9.0
EC000901
ECLASS 9.0
27-14-11-41
ECLASS 9.1
27-14-11-41
ECLASS 10.0
27-14-11-41
ECLASS 11.0
27-14-11-41
ECLASS 12.0
27-14-11-41
ECLASS 13.0
27-25-01-03
ECLASS 14.0
27-25-01-03
Approvals
ROHS
Conform
UL File Number Search
UL Website
Certificate No. (cURusEX)
E184763
There are no products in this group.
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.