Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Analogue Signal Conditioning
Power Supplies
Electronics Housings
Lightning and Surge Protection
Photovoltaics
e-mobility
Fieldbus Distributors
SPDs for energy systems
SPDs for instrumentation and control (I&C)
SPDs for data interfaces
Accessories
AC voltage
Photovoltaics
DIN rail TS 35
40mm busbars
Type I
Type II
Type III
VPU Type I Series
VPU Type II Series
230 V / 400 V
230 V / 400 V with integrated fuse
400 V / 690 V
950 V
Spare arrester
10 kA
25 kA LCF
Optical status indicator
Optical status indicator & remote alert
General ordering data
Version
Surge voltage arrester, Low voltage, Surge protection, Single-phase, TN
Order No.
2619100000
Type
VPU AC I 1 440/25 LCF
GTIN (EAN)
4050118633962
Qty.
1 pc(s).
Dimensions and weights
Depth
93 mm
Depth (inches)
3.661 inch
Height
90 mm
Height (inches)
3.543 inch
Width
36 mm
Width (inches)
1.417 inch
Net weight
25 g
Temperatures
Storage temperature
-40 °C...85 °C
Operating temperature
-40 °C...85 °C
Humidity
5 - 95% rel. humidity
Probability of failure
MTBF
15 a
Environmental Product Compliance
REACH SVHC
/
RoHS Compliance Status
Compliant without exemption
General data
Colour
black
Design
Installation housing; 2TE, Insta IP 20
Operating altitude
≤ 2000 m
Optical function display
green = OK; red = arrester is defective - replace
Protection degree
IP20 in installed state
Rail
TS 35
Segment
Power distribution
Suitable for
Count-in installation (leakage current free)
UL 94 flammability rating
V-0
Version
Surge protection
Insulation coordination acc. to EN 50178
Pollution severity
2
Surge voltage category
III
Rated data IEC / EN
Discharge current Imax (8/20µs) wire-PE
100 kA
Discharge current In (8/20µs) wire-PE
25 kA
Energy coordination (≤10 m)
Type I, Type II, Type III
Follow-on current extinguishing capability Ifi
Not available due for technical reasons
Frequency range, max.
60 Hz
Frequency range, min.
50 Hz
Fuse
250 A gL (if back up fuse > 250 A)
Leakage current at Un
5 µA
Lightning test current Iimp (10/350 µs) (L-PE)
25 kA
Low voltage network
Single-phase, TN
Mains voltage
400 V / 690 V
Max. continuous voltage, Uc (AC)
440 V
Number of poles
1
Protection level Up at IN (L/N-PE)
≤ 2.5 kV
Rated load current IL
100 A
Rated voltage (AC)
400 V
Requirements category acc. to IEC 61643-11
Type I, Type II
Requirements class, acc. to EN 61643-11
T1, T2
Response time
≤ 25 ns
Short-circuit current rating ISCCR
50 kA
Signalling contact
No
Standards
IEC 61643-11, EN 61643-11
Suitable for
Count-in installation (leakage current free)
Temporary surge voltage (over-voltage) - TOV
762 V
Voltage type
AC
Connection data
Stripping length
13 mm
Wire connection method
Screw connection
Type of connection
Screw connection
Stripping length, rated connection
13 mm
Tightening torque, min.
2 Nm
Tightening torque, max.
3 Nm
Clamping range, rated connection
16 mm²
Clamping range, min.
6 mm²
Clamping range, max.
35 mm²
Wire cross-section, solid, min.
6 mm²
Wire cross-section, solid, max.
35 mm²
Wire connection cross section, finely stranded, min.
6 mm²
Wire connection cross section, finely stranded, max.
35 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.
6 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.
35 mm²
Connection cross-section, stranded, min.
6 mm²
Connection cross-section, stranded, max.
35 mm²
Guarantee
Time interval
5 years
Important note
Product information
For use in DC applications, please use the fuse of SIBA Type NH2XL aR/aSF DC 1500 V
Notes
Only applicable to IT power systems where the earth on the distribution transformer is interconnected with the earth on the consumer side (RE=RA in Figure 44.A1 of IEC 60634-4-44:2018).
Classifications
ETIM 6.0
EC000941
ETIM 7.0
EC000941
ETIM 8.0
EC000941
ETIM 9.0
EC000941
ECLASS 9.0
27-13-08-05
ECLASS 9.1
27-13-08-05
ECLASS 10.0
27-13-08-05
ECLASS 11.0
27-13-08-05
ECLASS 12.0
27-17-90-90
ECLASS 13.0
27-17-90-90
ECLASS 14.0
27-17-90-90
Approvals
Approvals
ROHS
Conform
Order No.:
2619210000
Type of connection:
Screw connection
Type:
VPU AC I 1+1 440/25 LCF
Version:
Surge voltage arrester, Low voltage, Surge protection, Single-phase, TN, TT, IT with N, IT without N
Order No.:
2619130000
Type of connection:
Screw connection
Type:
VPU AC I 2 440/25 LCF
Version:
Surge voltage arrester, Low voltage, Surge protection, Single-phase, TN-S
Order No.:
2619160000
Type of connection:
Screw connection
Type:
VPU AC I 3 440/25 LCF
Version:
Surge voltage arrester, Low voltage, Surge protection, TN-C
Order No.:
2619240000
Type of connection:
Screw connection
Type:
VPU AC I 3+1 440/25 LCF
Version:
Surge voltage arrester, Low voltage, Surge protection, TN-C-S, TN-S, TT, IT with N, IT without N
Order No.:
2619190000
Type of connection:
Screw connection
Type:
VPU AC I 4 440/25 LCF
Version:
Surge voltage arrester, Low voltage, Surge protection, TN-C-S, TN-S
Version
Surge voltage arrester, Low voltage, Surge protection, Single-phase, TN
Order No.
2619100000
Type
VPU AC I 1 440/25 LCF
GTIN (EAN)
4050118633962
Qty.
1 pc(s).
Depth
93 mm
Depth (inches)
3.661 inch
Height
90 mm
Height (inches)
3.543 inch
Width
36 mm
Width (inches)
1.417 inch
Net weight
25 g
Storage temperature
-40 °C...85 °C
Operating temperature
-40 °C...85 °C
Humidity
5 - 95% rel. humidity
REACH SVHC
/
RoHS Compliance Status
Compliant without exemption
Colour
black
Design
Installation housing; 2TE, Insta IP 20
Operating altitude
≤ 2000 m
Optical function display
green = OK; red = arrester is defective - replace
Protection degree
IP20 in installed state
Rail
TS 35
Segment
Power distribution
Suitable for
Count-in installation (leakage current free)
UL 94 flammability rating
V-0
Version
Surge protection
Pollution severity
2
Surge voltage category
III
Discharge current Imax (8/20µs) wire-PE
100 kA
Discharge current In (8/20µs) wire-PE
25 kA
Energy coordination (≤10 m)
Type I, Type II, Type III
Follow-on current extinguishing capability Ifi
Not available due for technical reasons
Frequency range, max.
60 Hz
Frequency range, min.
50 Hz
Fuse
250 A gL (if back up fuse > 250 A)
Leakage current at Un
5 µA
Lightning test current Iimp (10/350 µs) (L-PE)
25 kA
Low voltage network
Single-phase, TN
Mains voltage
400 V / 690 V
Max. continuous voltage, Uc (AC)
440 V
Number of poles
1
Protection level Up at IN (L/N-PE)
≤ 2.5 kV
Rated load current IL
100 A
Rated voltage (AC)
400 V
Requirements category acc. to IEC 61643-11
Type I, Type II
Requirements class, acc. to EN 61643-11
T1, T2
Response time
≤ 25 ns
Short-circuit current rating ISCCR
50 kA
Signalling contact
No
Standards
IEC 61643-11, EN 61643-11
Suitable for
Count-in installation (leakage current free)
Temporary surge voltage (over-voltage) - TOV
762 V
Voltage type
AC
Stripping length
13 mm
Wire connection method
Screw connection
Type of connection
Screw connection
Stripping length, rated connection
13 mm
Tightening torque, min.
2 Nm
Tightening torque, max.
3 Nm
Clamping range, rated connection
16 mm²
Clamping range, min.
6 mm²
Clamping range, max.
35 mm²
Wire cross-section, solid, min.
6 mm²
Wire cross-section, solid, max.
35 mm²
Wire connection cross section, finely stranded, min.
6 mm²
Wire connection cross section, finely stranded, max.
35 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.
6 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.
35 mm²
Connection cross-section, stranded, min.
6 mm²
Connection cross-section, stranded, max.
35 mm²
Product information
For use in DC applications, please use the fuse of SIBA Type NH2XL aR/aSF DC 1500 V
Notes
Only applicable to IT power systems where the earth on the distribution transformer is interconnected with the earth on the consumer side (RE=RA in Figure 44.A1 of IEC 60634-4-44:2018).
ETIM 6.0
EC000941
ETIM 7.0
EC000941
ETIM 8.0
EC000941
ETIM 9.0
EC000941
ECLASS 9.0
27-13-08-05
ECLASS 9.1
27-13-08-05
ECLASS 10.0
27-13-08-05
ECLASS 11.0
27-13-08-05
ECLASS 12.0
27-17-90-90
ECLASS 13.0
27-17-90-90
ECLASS 14.0
27-17-90-90
Approvals
ROHS
Conform
Order No.:
2619210000
Type of connection:
Screw connection
Type:
VPU AC I 1+1 440/25 LCF
Version:
Surge voltage arrester, Low voltage, Surge protection, Single-phase, TN, TT, IT with N, IT without N
Order No.:
2619130000
Type of connection:
Screw connection
Type:
VPU AC I 2 440/25 LCF
Version:
Surge voltage arrester, Low voltage, Surge protection, Single-phase, TN-S
Order No.:
2619160000
Type of connection:
Screw connection
Type:
VPU AC I 3 440/25 LCF
Version:
Surge voltage arrester, Low voltage, Surge protection, TN-C
Order No.:
2619240000
Type of connection:
Screw connection
Type:
VPU AC I 3+1 440/25 LCF
Version:
Surge voltage arrester, Low voltage, Surge protection, TN-C-S, TN-S, TT, IT with N, IT without N
Order No.:
2619190000
Type of connection:
Screw connection
Type:
VPU AC I 4 440/25 LCF
Version:
Surge voltage arrester, Low voltage, Surge protection, TN-C-S, TN-S
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.