Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Controls
I/O Systems
Industrial Ethernet
Touch Panels
Engineering and Visualisation Tools
Measuring and Monitoring Systems
Automated Machine Learning
easyConnect
Energy Meter
Energy Analyser
Energy / Data Logger
Current transformer
Retrofit energy solutions
Mechanical- & electronic sensors
Accessories
Energy meters – BasicLine
Energy meters – ValueLine
Energy meters - DC Microgrids
General ordering data
Version
Power measurement/display for 1-, 3-phase mains
Order No.
2540870000
Type
ENERGY METER 610-PB-230
GTIN (EAN)
4050118552997
Qty.
1 pc(s).
Dimensions and weights
Depth
65 mm
Depth (inches)
2.559 inch
Height
96 mm
Height (inches)
3.78 inch
Width
96 mm
Width (inches)
3.78 inch
Net weight
250 g
Temperatures
Storage temperature
-25 °C...70 °C
Humidity at storage temperature
0...90 % RH
Operating temperature
-10 °C...55 °C
Humidity at operating temperature
0 - 75% RH
Environmental Product Compliance
RoHS Compliance Status
Compliant without exemption
REACH SVHC
No SVHC above 0.1 wt%
Measuring current input
Current-measuring channels
4
Distortion factor THD-I in %
Yes
Harmonics, per order / current
1.-40.
Measuring accuracy for current
0.2 %
Residual current measuring
No
Measuring voltage input
Distortion factor THD-U in %
Yes
Four-wire system
Yes
Harmonics, per order / voltage
1.-40.
Measurement range, voltage L-L, AC
480 V
Measurement range, voltage L-N, AC
277 V
Measuring accuracy for voltage
0.2 %
Quadrants
4
Three-wire system
Yes
Communication
Interface
RS485: 9,6 – 115,2 kbps, Profibus DP, USB
Protocol
Modbus RTU, Profibus DP V0
Inputs/outputs
Number of digital inputs
4
Number of digital outputs
6
Number of pulse outputs
6
Temperature input
No
Measurement data recording
Memory; minimum and maximum values
Yes
Memory size
256 MB
Number of memory values
10,000 k
Update interval register
200 ms
Min. memory recording interval
60 s
Software
ecoExplorer go®
Integrated logic
Yes
Technical data
Protection degree
IP20, IP40
Version
Power measurement/display for 1-, 3-phase mains
Standards
DIN EN 61326-1, IEC 61010-1, IEC 61010-2-030
Measurement range, voltage L-N, AC
277 V
Measurement range, voltage L-L, AC
480 V
Surge voltage category
300 V CAT III
Voltage supply
90 - 277 V AC (50/60 Hz), 90 - 250 V DC
Supply voltage
230 V
Three-wire system
Yes
Four-wire system
Yes
Quadrants
4
Sampling frequency 50/60 Hz
25.6 kHz
Continuous measurements
Yes
Measurement result per second
5 ms
Effective value from the period (50/60 Hz)
10 / 12
Residual current measuring
No
Current-measuring channels
4
Measuring accuracy for voltage
0.2 %
Measuring accuracy for current
0.2 %
Measurement accuracy for active energy (kWh, .../5 A)
Class 0.5S
Operating-hours counter
Yes
Weekly time switch
No
Clock
Yes
Bimetal function
Yes
Voltage quality measurement
Harmonics, per order / voltage
1.-40.
Harmonics, per order / current
1.-40.
Distortion factor THD-U in %
Yes
Distortion factor THD-I in %
Yes
Unbalanced
No
Positive, negative and zero system
Yes
Brief interruptions
No
Sequence-of-events recorder function
No
Insulation coordination
Surge voltage category
300 V CAT III
Downloads
Approval/Certificate/Document of Conformity
Engineering Data
CADENAS eCATALOG
CAX data
Software
User Documentation
Catalogues
Catalogues in PDF-format
Classifications
ETIM 6.0
EC002301
ETIM 7.0
EC002301
ETIM 8.0
EC002301
ETIM 9.0
EC002301
ECLASS 9.0
27-14-23-30
ECLASS 9.1
27-21-03-01
ECLASS 10.0
27-14-23-30
ECLASS 11.0
27-14-23-30
ECLASS 12.0
27-14-23-30
ECLASS 13.0
27-14-23-30
ECLASS 14.0
27-14-23-30
Approvals
Approvals
Approvals
CE
ROHS
Conform
UL File Number Search
UL Website
Certificate no. (cULus)
E469563
Order No.:
2425420000
Type:
ENERGY METER 350
Version:
Power measurement/display for 1-, 3-phase mains
Delivery status:
This article will no longer be available in the future.
Order No.:
2500880000
Type:
ENERGY METER 520-230
Version:
Power measurement/display for 1-, 3-phase mains
Order No.:
2500860000
Type:
ENERGY METER 520-24
Version:
Power measurement/display for 1-, 3-phase mains
Order No.:
2540890000
Type:
ENERGY METER 525-230
Version:
Power measurement/display for 1-, 3-phase mains
Order No.:
2540880000
Type:
ENERGY METER 525-24
Version:
Power measurement/display for 1-, 3-phase mains
Order No.:
2540850000
Type:
ENERGY METER 610-230
Version:
Power measurement/display for 1-, 3-phase mains
Order No.:
2540920000
Type:
ENERGY METER 610-24
Version:
Power measurement/display for 1-, 3-phase mains
Order No.:
2540860000
Type:
ENERGY METER 610-PB-24
Version:
Power measurement/display for 1-, 3-phase mains
Order No.:
2500890000
Type:
ENERGY METER 700-PN-230
Version:
Power measurement/display for 1-, 3-phase mains
Order No.:
2500870000
Type:
ENERGY METER 700-PN-24
Version:
Power measurement/display for 1-, 3-phase mains
Order No.:
2540910000
Type:
ENERGY METER 750-230
Version:
Power measurement/display for 1-, 3-phase mains
Order No.:
2540900000
Type:
ENERGY METER 750-24
Version:
Power measurement/display for 1-, 3-phase mains
Order No.:
2540830000
Type:
ENERGY METER D370-CBM
Version:
Power measurement/display for 1-, 3-phase mains
Order No.:
2425490000
Type:
ENERGY METER D650
Version:
Power measurement/display for 1-, 3-phase mains
Order No.:
1423550000
Type:
POWER MONITOR
Version:
Power measurement/display for 1-, 3-phase mains
Order No.:
1470260000
Type:
POWER MONITOR 51A
Version:
Power measurement/display for 1-, 3-phase mains
Version
Power measurement/display for 1-, 3-phase mains
Order No.
2540870000
Type
ENERGY METER 610-PB-230
GTIN (EAN)
4050118552997
Qty.
1 pc(s).
Depth
65 mm
Depth (inches)
2.559 inch
Height
96 mm
Height (inches)
3.78 inch
Width
96 mm
Width (inches)
3.78 inch
Net weight
250 g
Storage temperature
-25 °C...70 °C
Humidity at storage temperature
0...90 % RH
Operating temperature
-10 °C...55 °C
Humidity at operating temperature
0 - 75% RH
RoHS Compliance Status
Compliant without exemption
REACH SVHC
No SVHC above 0.1 wt%
Current-measuring channels
4
Distortion factor THD-I in %
Yes
Harmonics, per order / current
1.-40.
Measuring accuracy for current
0.2 %
Residual current measuring
No
Distortion factor THD-U in %
Yes
Four-wire system
Yes
Harmonics, per order / voltage
1.-40.
Measurement range, voltage L-L, AC
480 V
Measurement range, voltage L-N, AC
277 V
Measuring accuracy for voltage
0.2 %
Quadrants
4
Three-wire system
Yes
Interface
RS485: 9,6 – 115,2 kbps, Profibus DP, USB
Protocol
Modbus RTU, Profibus DP V0
Number of digital inputs
4
Number of digital outputs
6
Number of pulse outputs
6
Temperature input
No
Memory; minimum and maximum values
Yes
Memory size
256 MB
Number of memory values
10,000 k
Update interval register
200 ms
Min. memory recording interval
60 s
Software
ecoExplorer go®
Integrated logic
Yes
Protection degree
IP20, IP40
Version
Power measurement/display for 1-, 3-phase mains
Standards
DIN EN 61326-1, IEC 61010-1, IEC 61010-2-030
Measurement range, voltage L-N, AC
277 V
Measurement range, voltage L-L, AC
480 V
Surge voltage category
300 V CAT III
Voltage supply
90 - 277 V AC (50/60 Hz), 90 - 250 V DC
Supply voltage
230 V
Three-wire system
Yes
Four-wire system
Yes
Quadrants
4
Sampling frequency 50/60 Hz
25.6 kHz
Continuous measurements
Yes
Measurement result per second
5 ms
Effective value from the period (50/60 Hz)
10 / 12
Residual current measuring
No
Current-measuring channels
4
Measuring accuracy for voltage
0.2 %
Measuring accuracy for current
0.2 %
Measurement accuracy for active energy (kWh, .../5 A)
Class 0.5S
Operating-hours counter
Yes
Weekly time switch
No
Clock
Yes
Bimetal function
Yes
Harmonics, per order / voltage
1.-40.
Harmonics, per order / current
1.-40.
Distortion factor THD-U in %
Yes
Distortion factor THD-I in %
Yes
Unbalanced
No
Positive, negative and zero system
Yes
Brief interruptions
No
Sequence-of-events recorder function
No
Surge voltage category
300 V CAT III
ETIM 6.0
EC002301
ETIM 7.0
EC002301
ETIM 8.0
EC002301
ETIM 9.0
EC002301
ECLASS 9.0
27-14-23-30
ECLASS 9.1
27-21-03-01
ECLASS 10.0
27-14-23-30
ECLASS 11.0
27-14-23-30
ECLASS 12.0
27-14-23-30
ECLASS 13.0
27-14-23-30
ECLASS 14.0
27-14-23-30
Approvals
Approvals
CE
ROHS
Conform
UL File Number Search
UL Website
Certificate no. (cULus)
E469563
Order No.:
2425420000
Type:
ENERGY METER 350
Version:
Power measurement/display for 1-, 3-phase mains
Delivery status:
This article will no longer be available in the future.
Order No.:
2500880000
Type:
ENERGY METER 520-230
Version:
Power measurement/display for 1-, 3-phase mains
Order No.:
2500860000
Type:
ENERGY METER 520-24
Version:
Power measurement/display for 1-, 3-phase mains
Order No.:
2540890000
Type:
ENERGY METER 525-230
Version:
Power measurement/display for 1-, 3-phase mains
Order No.:
2540880000
Type:
ENERGY METER 525-24
Version:
Power measurement/display for 1-, 3-phase mains
Order No.:
2540850000
Type:
ENERGY METER 610-230
Version:
Power measurement/display for 1-, 3-phase mains
Order No.:
2540920000
Type:
ENERGY METER 610-24
Version:
Power measurement/display for 1-, 3-phase mains
Order No.:
2540860000
Type:
ENERGY METER 610-PB-24
Version:
Power measurement/display for 1-, 3-phase mains
Order No.:
2500890000
Type:
ENERGY METER 700-PN-230
Version:
Power measurement/display for 1-, 3-phase mains
Order No.:
2500870000
Type:
ENERGY METER 700-PN-24
Version:
Power measurement/display for 1-, 3-phase mains
Order No.:
2540910000
Type:
ENERGY METER 750-230
Version:
Power measurement/display for 1-, 3-phase mains
Order No.:
2540900000
Type:
ENERGY METER 750-24
Version:
Power measurement/display for 1-, 3-phase mains
Order No.:
2540830000
Type:
ENERGY METER D370-CBM
Version:
Power measurement/display for 1-, 3-phase mains
Order No.:
2425490000
Type:
ENERGY METER D650
Version:
Power measurement/display for 1-, 3-phase mains
Order No.:
1423550000
Type:
POWER MONITOR
Version:
Power measurement/display for 1-, 3-phase mains
Order No.:
1470260000
Type:
POWER MONITOR 51A
Version:
Power measurement/display for 1-, 3-phase mains
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.