Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Analogue Signal Conditioning
Power Supplies
Electronics Housings
Lightning and Surge Protection
e-mobility
Photovoltaics
Fieldbus Distributors
SPDs for energy systems
SPDs for instrumentation and control (I&C)
SPDs for data interfaces
Accessories
AC voltage
Photovoltaics
VPU PV I + II
VPU PV II
600 V
1000 V
1500 V
With remote alert
Without remote alert
Spare Arrester
General ordering data
Version
Surge voltage arrester, Low voltage, Surge protection I / II, Spare arrester
Order No.
2534300000
Type
VPU PV I+II 0M 1000
GTIN (EAN)
4050118545906
Qty.
9 pc(s).
Dimensions and weights
Depth
79 mm
Depth (inches)
3.11 inch
Height
45 mm
Height (inches)
1.772 inch
Width
18 mm
Width (inches)
0.709 inch
Net weight
65 g
Temperatures
Storage temperature
85 °C
Operating temperature
-40 °C...85 °C
Humidity
5 - 95% rel. humidity
Environmental Product Compliance
RoHS Compliance Status
Compliant without exemption
REACH SVHC
No SVHC above 0.1 wt%
Rated data UL
Ambient temperature (operational), max.
85 °C
Rated Voltage UN
550 V
SCCR
50 kA
In
20 kA
Category
SPD TYPE 1CA
Ambient temperature (operational), min.
-40 °C
Certificate No. (cURus)
E354261
VPR ( DC+/DC-)
2,500 V
Voltage type
DC
General data
Number of poles
1
Protection degree
IP20
Colour
orange
Insulation coordination acc. to EN 50178
Pollution severity
2
Surge voltage category
III
Photovoltaic technical data
Discharge current In (8/20 µs)
20 kA
Lightning test current Iimp (10/350 µs)
6.25 kA
Operating height in the grounded PV system
≤ 2000 m
PV system voltage, max. Ucpv
1,100 V
Protection level Up (+/- , -/PE , +/PE)
≤ 3.8 kV
Requirements class
Type I/II
Short-circuit curent ISCPV
11,000 A
Standards
EN 61643-31, EN 50539-11, UL 1449
Total discharge current Itotal ( 8/20µs)
50 kA
Total discharge current Itotal (10/350µs)
12.5 kA
Rated data IEC / EN
Leakage current at Un
30 µA
Lightning test current Iimp (10/350 µs)
6.25 kA
Number of poles
1
Response time
≤ 25 ns
SPD type
T1, T2
Standards
EN 61643-31, EN 50539-11, UL 1449
Voltage type
DC
Connection data
Type of connection
pluggable
Electrical data
Voltage type
DC
Guarantee
Time interval
5 years
Classifications
ETIM 6.0
EC000941
ETIM 7.0
EC000941
ETIM 8.0
EC000941
ETIM 9.0
EC000941
ECLASS 9.0
27-13-08-05
ECLASS 9.1
27-13-08-05
ECLASS 10.0
27-13-08-05
ECLASS 11.0
27-13-08-05
ECLASS 12.0
27-17-90-90
ECLASS 13.0
27-17-90-90
ECLASS 14.0
27-17-90-90
Approvals
Approvals
ROHS
Conform
UL File Number Search
UL Website
Certificate No. (cURus)
E354261
Type of connection:
pluggable
Order No.:
2530600000
Type:
VPU PV I+II 0 1000
Version:
Surge voltage arrester, Low voltage, Accessories, Surge protection I / II, Spare arrester
Type of connection:
pluggable
Order No.:
2530530000
Type:
VPU PV I+II 0 1000 E
Version:
Surge voltage arrester, Low voltage, Accessories, Surge protection I / II, Spare arrester
Type of connection:
pluggable
Order No.:
2857000000
Type:
VPU PV I+II 5 0 1000
Type of connection:
pluggable
Order No.:
2856650000
Type:
VPU PV I+II 5 0M 1000
Version
Surge voltage arrester, Low voltage, Surge protection I / II, Spare arrester
Order No.
2534300000
Type
VPU PV I+II 0M 1000
GTIN (EAN)
4050118545906
Qty.
9 pc(s).
Depth
79 mm
Depth (inches)
3.11 inch
Height
45 mm
Height (inches)
1.772 inch
Width
18 mm
Width (inches)
0.709 inch
Net weight
65 g
Storage temperature
85 °C
Operating temperature
-40 °C...85 °C
Humidity
5 - 95% rel. humidity
RoHS Compliance Status
Compliant without exemption
REACH SVHC
No SVHC above 0.1 wt%
Ambient temperature (operational), max.
85 °C
Rated Voltage UN
550 V
SCCR
50 kA
In
20 kA
Category
SPD TYPE 1CA
Ambient temperature (operational), min.
-40 °C
Certificate No. (cURus)
E354261
VPR ( DC+/DC-)
2,500 V
Voltage type
DC
Number of poles
1
Protection degree
IP20
Colour
orange
Pollution severity
2
Surge voltage category
III
Discharge current In (8/20 µs)
20 kA
Lightning test current Iimp (10/350 µs)
6.25 kA
Operating height in the grounded PV system
≤ 2000 m
PV system voltage, max. Ucpv
1,100 V
Protection level Up (+/- , -/PE , +/PE)
≤ 3.8 kV
Requirements class
Type I/II
Short-circuit curent ISCPV
11,000 A
Standards
EN 61643-31, EN 50539-11, UL 1449
Total discharge current Itotal ( 8/20µs)
50 kA
Total discharge current Itotal (10/350µs)
12.5 kA
Leakage current at Un
30 µA
Lightning test current Iimp (10/350 µs)
6.25 kA
Number of poles
1
Response time
≤ 25 ns
SPD type
T1, T2
Standards
EN 61643-31, EN 50539-11, UL 1449
Voltage type
DC
Type of connection
pluggable
ETIM 6.0
EC000941
ETIM 7.0
EC000941
ETIM 8.0
EC000941
ETIM 9.0
EC000941
ECLASS 9.0
27-13-08-05
ECLASS 9.1
27-13-08-05
ECLASS 10.0
27-13-08-05
ECLASS 11.0
27-13-08-05
ECLASS 12.0
27-17-90-90
ECLASS 13.0
27-17-90-90
ECLASS 14.0
27-17-90-90
Approvals
ROHS
Conform
UL File Number Search
UL Website
Certificate No. (cURus)
E354261
Type of connection:
pluggable
Order No.:
2530600000
Type:
VPU PV I+II 0 1000
Version:
Surge voltage arrester, Low voltage, Accessories, Surge protection I / II, Spare arrester
Type of connection:
pluggable
Order No.:
2530530000
Type:
VPU PV I+II 0 1000 E
Version:
Surge voltage arrester, Low voltage, Accessories, Surge protection I / II, Spare arrester
Type of connection:
pluggable
Order No.:
2857000000
Type:
VPU PV I+II 5 0 1000
Type of connection:
pluggable
Order No.:
2856650000
Type:
VPU PV I+II 5 0M 1000
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.