Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Analogue Signal Conditioning
Power Supplies
Electronics Housings
Lightning and Surge Protection
Photovoltaics
e-mobility
Fieldbus Distributors
Network-compatible current measuring transducers ACT20C
intrinsically safe signal converter - ACT20X
signal converter and process monitoring - ACT20P
Space-saving signal converter - ACT20M
Signal converter in terminal block format - MCZ
Compact standard signal isolators - PicoPak
Process monitoring displays
Analogue-digital / digital-analogue converter
Signal - & serial interface converter– WAVESERIES
Configuration software
Accessories
General ordering data
Version
Signal converter/insulator, Output current loop powered, Input : 4-20 mA, Output : 4-20 mA
Order No.
2517450000
Type
PICOPAK-CI-CO-LP-S
GTIN (EAN)
4050118529975
Qty.
1 pc(s).
Dimensions and weights
Depth
55 mm
Depth (inches)
2.165 inch
Height
79.4 mm
Height (inches)
3.126 inch
Width
6.1 mm
Width (inches)
0.24 inch
Net weight
44 g
Temperatures
Storage temperature
-40 °C...85 °C
Operating temperature
-40 °C...55 °C
Humidity at operating temperature
0...95 % (no condensation)
Humidity
0...95 % (no condensation)
Probability of failure
SIL in compliance with IEC 61508
None
Environmental Product Compliance
REACH SVHC
Lead 7439-92-1
SCIP
f814e8b7-24eb-4ad1-8545-4d3e652b59d1
RoHS Compliance Status
Compliant with exemption
RoHS Exemption (if applicable/known)
6c, 7a, 7cI
Input
Input current
4...20 mA @ 6...35 V DC
Number of inputs
1
Sensor
Current source
Voltage drop, current input
≤3,5 V
Output
Cut-off frequency (-3 dB)
≥3,5 kHz
Load impedance current
≤ 600 Ω, @ max 23mA
Number of outputs
1
Output current
4...20 mA, loop-powered
Supply voltage (output)
18…32 V
General data
Accuracy
<0.1 % of measuring range
Configuration
Potentiometer, Zero / Span
Galvanic isolation
2-way isolator
Power consumption, max.
0.85 W
Power consumption, typ.
0.55 W
Protection degree
IP20
Rail
TS 35
Standard
EN 61010-1, EN 61326-1, UL 61010-1:2012, 3rd Edition
Step response time
≤ 5 ms
Temperature coefficient
≤ 200 ppm/K
Voltage supply
Output loop powered
Insulation coordination
EMC standards
EN 61326-1
Galvanic isolation
2-way isolator
Insulation voltage
3.5 kV
Pollution severity
2
Rated voltage
300 V ACrms
Standard
EN 61010-1, EN 61326-1, UL 61010-1:2012, 3rd Edition
Surge voltage category
II
Connection data
Type of connection
Screw connection
Tightening torque, max.
0.6 Nm
Wire connection cross section, finely stranded, min.
0.5 mm²
Wire connection cross section, finely stranded, max.
2.5 mm²
Wire cross-section, finely stranded, min. (AWG)
AWG 20
Wire cross-section, finely stranded, max. (AWG)
AWG 12
Important note
Product information
The passive Isolator PicoPak-CI-CO-LP separates stand- analogue current signals. An analogue input current signal is converted linear and galvanic isolated into an analogue out- put current signal. The power supply occurs through the input and output measuring circuit. The measuring range can be adjusted if necessary via the potentiometers (Zero and Span) installed on the front.
Classifications
ETIM 6.0
EC002653
ETIM 7.0
EC002653
ETIM 8.0
EC002653
ETIM 9.0
EC002653
ECLASS 9.0
27-21-01-20
ECLASS 9.1
27-21-01-20
ECLASS 10.0
27-21-01-20
ECLASS 11.0
27-21-01-20
ECLASS 12.0
27-21-01-20
ECLASS 13.0
27-21-01-20
ECLASS 14.0
27-21-01-20
Order No.:
2501110000
Type of connection:
PUSH IN
Type:
PICOPAK-CI-CO-LP-P
Version:
Signal converter/insulator, Output current loop powered, Input : 4-20 mA, Output : 4-20 mA
Version
Signal converter/insulator, Output current loop powered, Input : 4-20 mA, Output : 4-20 mA
Order No.
2517450000
Type
PICOPAK-CI-CO-LP-S
GTIN (EAN)
4050118529975
Qty.
1 pc(s).
Depth
55 mm
Depth (inches)
2.165 inch
Height
79.4 mm
Height (inches)
3.126 inch
Width
6.1 mm
Width (inches)
0.24 inch
Net weight
44 g
Storage temperature
-40 °C...85 °C
Operating temperature
-40 °C...55 °C
Humidity at operating temperature
0...95 % (no condensation)
Humidity
0...95 % (no condensation)
SIL in compliance with IEC 61508
None
REACH SVHC
Lead 7439-92-1
SCIP
f814e8b7-24eb-4ad1-8545-4d3e652b59d1
RoHS Compliance Status
Compliant with exemption
RoHS Exemption (if applicable/known)
6c, 7a, 7cI
Input current
4...20 mA @ 6...35 V DC
Number of inputs
1
Sensor
Current source
Voltage drop, current input
≤3,5 V
Cut-off frequency (-3 dB)
≥3,5 kHz
Load impedance current
≤ 600 Ω, @ max 23mA
Number of outputs
1
Output current
4...20 mA, loop-powered
Supply voltage (output)
18…32 V
Accuracy
<0.1 % of measuring range
Configuration
Potentiometer, Zero / Span
Galvanic isolation
2-way isolator
Power consumption, max.
0.85 W
Power consumption, typ.
0.55 W
Protection degree
IP20
Rail
TS 35
Standard
EN 61010-1, EN 61326-1, UL 61010-1:2012, 3rd Edition
Step response time
≤ 5 ms
Temperature coefficient
≤ 200 ppm/K
Voltage supply
Output loop powered
EMC standards
EN 61326-1
Galvanic isolation
2-way isolator
Insulation voltage
3.5 kV
Pollution severity
2
Rated voltage
300 V ACrms
Standard
EN 61010-1, EN 61326-1, UL 61010-1:2012, 3rd Edition
Surge voltage category
II
Type of connection
Screw connection
Tightening torque, max.
0.6 Nm
Wire connection cross section, finely stranded, min.
0.5 mm²
Wire connection cross section, finely stranded, max.
2.5 mm²
Wire cross-section, finely stranded, min. (AWG)
AWG 20
Wire cross-section, finely stranded, max. (AWG)
AWG 12
Product information
The passive Isolator PicoPak-CI-CO-LP separates stand- analogue current signals. An analogue input current signal is converted linear and galvanic isolated into an analogue out- put current signal. The power supply occurs through the input and output measuring circuit. The measuring range can be adjusted if necessary via the potentiometers (Zero and Span) installed on the front.
ETIM 6.0
EC002653
ETIM 7.0
EC002653
ETIM 8.0
EC002653
ETIM 9.0
EC002653
ECLASS 9.0
27-21-01-20
ECLASS 9.1
27-21-01-20
ECLASS 10.0
27-21-01-20
ECLASS 11.0
27-21-01-20
ECLASS 12.0
27-21-01-20
ECLASS 13.0
27-21-01-20
ECLASS 14.0
27-21-01-20
Approvals
ROHS
Conform
UL File Number Search
UL Website
Certificate No. (cURus)
E141197
Certificate no. (cULusEX)
E223527
Order No.:
2501110000
Type of connection:
PUSH IN
Type:
PICOPAK-CI-CO-LP-P
Version:
Signal converter/insulator, Output current loop powered, Input : 4-20 mA, Output : 4-20 mA
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.