Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Isolating amplifier and measuring transducer
Power Supplies
Electronics Housings
Lightning and Surge Protection
e-mobility
Photovoltaics
Fieldbus Distributors
Network-compatible measuring transducer - ACT20C
intrinsically safe signal converter - ACT20X
signal converter and process monitoring - ACT20P
Space-saving signal converter - ACT20M
Signal converter in terminal block format - MCZ
Compact standard signal isolators - PicoPak
Process monitoring displays
Analogue-digital / digital-analogue converter
Signal - & serial interface converter– WAVESERIES
Configuration software
Accessories
Isolating amplifiers
Passive isolator
Isolating amplifiers with splitter function
Temperature transducer
Trip amplifier
Current measuring transducer
Strain gauge transducer
Frequency transducer
Universal transducer
Universal transducer, loop powered
Serial interface converter
General ordering data
Version
Analogue isolating amplifier, Input : 0(4)-20 mA, Output : 0(4)-20 mA, Voltage supply also via CH20M rail bus, HART®
Order No.
2514620000
Type
ACT20P-CI-CO-P-P
GTIN (EAN)
4050118535198
Qty.
1 pc(s).
Dimensions and weights
Depth
113.7 mm
Depth (inches)
4.476 inch
Height
127.1 mm
Height (inches)
5.004 inch
Width
12.5 mm
Width (inches)
0.492 inch
Net weight
140 g
Temperatures
Operating temperature
-20 °C...60 °C
Humidity at operating temperature
0...95 % (no condensation)
Probability of failure
SIL in compliance with IEC 61508
None
Environmental Product Compliance
RoHS Compliance Status
Compliant with exemption
RoHS Exemption (if applicable/known)
7a, 7cI
REACH SVHC
Lead 7439-92-1
SCIP
2f6dd957-421a-46db-a0c2-cf1609156924
Input
Input current
0...20 mA, 4…20mA
Input signal
HART signal® bidirectional
Number of inputs
1
Sensor
2-wire transmitter (without own power supply), 3-wire sensor, 4- wire sensor (with own power supply)
Sensor supply
> 17 V DC at 20 mA
Voltage drop
≤ 1 V
Output
Load impedance current
≤ 550 Ω
Number of outputs
1
Output current
0…20 mA (if input: 0…20 mA), 4…20 mA (if input: 4…20 mA), HART® digital signal
Type
active, connected control must be passive
Output (digital)
Max. switching voltage, AC
0 V
Max. switching voltage, DC
0 V
Rated switching current
0.1 A
General data
Accuracy
<0.1 % of end value
Configuration
none
Current consumption
≤60 mA (24V power supply, 20mA output)
Galvanic isolation
3-way isolator, between input ⁄ output ⁄ supply
Nominal power consumption
2 VA
Operating altitude
≤ 2000 m
Protection degree
IP20
Rail
TS 35
Step response time
≤ 0,5 ms
Temperature coefficient
80 ppm/K
Type of signal forwarding according to HART®
unchanged
Voltage supply
20…30 V at terminal or via CH20M rail bus
Insulation coordination
EMC standards
EN 61326-1, EN 61000-6-2, EN 61000-6-4
Galvanic isolation
3-way isolator, between input ⁄ output ⁄ supply
Impulse withstand voltage
4 kV (1.2/50 µs)
Insulation voltage
2 kV inputs / outputs / power supply
Pollution severity
2
Surge voltage category
III
Test voltage
0.3 kV
Data for Ex applications (ATEX)
Marking
II 3 G Ex ec IIC T5 Gc
Connection data
Type of connection
PUSH IN
Tightening torque, min.
0.4 Nm
Tightening torque, max.
0.6 Nm
Clamping range, rated connection
2.5 mm²
Clamping range, min.
0.5 mm²
Clamping range, max.
2.5 mm²
Wire connection cross section AWG, min.
AWG 26
Wire connection cross section AWG, max.
AWG 14
Wire cross-section, solid, min.
0.2 mm²
Wire cross-section, solid, max.
2.5 mm²
Wire connection cross section, finely stranded, min.
0.5 mm²
Wire connection cross section, finely stranded, max.
2.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.
0.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.
2.5 mm²
Important note
Product information
The non-adjustable DC isolating amplifier ACT20P-CI-CO isolates analogue standard current signals from a power source or from a 2- or 3-wire sensor. An analogue input current signal is linearly converted into an analogue output current signal and is galvanically isolated. The power supply is galvanically isolated from the input and output (3-way isolation).
Properties
HART-compatible for 0.5 - 2.5 kHz
The active or passive mA signal inputs are fully galvanically isolated.
Operating status display on a front panel LED
Galvanic 3-way isolation between input, output and supply.
Classifications
ETIM 6.0
EC002653
ETIM 7.0
EC002653
ETIM 8.0
EC002653
ETIM 9.0
EC002653
ECLASS 9.0
27-21-01-20
ECLASS 9.1
27-21-01-20
ECLASS 10.0
27-21-01-20
ECLASS 11.0
27-21-01-20
ECLASS 12.0
27-21-01-20
ECLASS 13.0
27-21-01-20
ECLASS 14.0
27-21-01-20
Type of connection:
Screw connection
Order No.:
7760054114
Type:
ACT20P-CI-CO-S
Version:
Analogue isolating amplifier, Input : 0(4)-20 mA, Output : 0(4)-20 mA, Signal converter/isolator, HART®
Type of connection:
PUSH IN
Order No.:
2489680000
Type:
ACT20P-CI-CO-P
Version:
Analogue isolating amplifier, Input : 0(4)-20 mA, Output : 0(4)-20 mA, Signal converter/isolator, HART®
Type of connection:
Screw connection
Order No.:
1506200000
Type:
ACT20P-CI-CO-P-S
Version:
Analogue isolating amplifier, Input : 0(4)-20 mA, Output : 0(4)-20 mA, Voltage supply also via CH20M rail bus, HART®
Type of connection:
Screw connection
Order No.:
7760054117
Type:
ACT20P-2CI-2CO-12-S
Version:
Analogue isolating amplifier, Input : 2 x 0(4) - 20 mA, Output : 2 x 4-20 mA, Signal converter/isolator, HART®
Type of connection:
PUSH IN
Order No.:
2489730000
Type:
ACT20P-2CI-2CO-12-P
Version:
Analogue isolating amplifier, Input : 2 x 0(4) - 20 mA, Output : 2 x 4-20 mA, Signal converter/isolator, HART®
Type of connection:
PUSH IN
Order No.:
2514650000
Type:
ACT20P-2CI-2CO-12-P-P
Version:
Analogue isolating amplifier, Input : 2 x 0(4) - 20 mA, Output : 0(4)-20 mA, Voltage supply also via CH20M rail bus, HART®
Type of connection:
Screw connection
Order No.:
1506210000
Type:
ACT20P-2CI-2CO-12P-S
Version:
Analogue isolating amplifier, Input : 2 x 0(4) - 20 mA, Output : 0(4)-20 mA, Voltage supply also via CH20M rail bus, HART®
Type of connection:
Screw connection
Order No.:
1540010000
Type:
ACT20P-CI-VO-S
Version:
Analogue isolating amplifier, Input : 0(4)-20 mA, Output : 0-10 V, Signal converter/isolator
Type of connection:
PUSH IN
Order No.:
2489740000
Type:
ACT20P-CI-VO-P
Version:
Analogue isolating amplifier, Input : 0(4)-20 mA, Output : 0-10 V, Signal converter/isolator
Type of connection:
Screw connection
Order No.:
1537750000
Type:
ACT20P-CI-VO-P-S
Version:
Analogue isolating amplifier, Input : 0(4)-20 mA, Output : 0-10 V, Voltage supply also via CH20M rail bus, Signal converter/isolator
Type of connection:
PUSH IN
Order No.:
2514640000
Type:
ACT20P-CI-VO-P-P
Version:
Analogue isolating amplifier, Input : 0(4)-20 mA, Output : 0-10 V, Voltage supply also via CH20M rail bus, Signal converter/isolator
Type of connection:
Screw connection
Order No.:
7760054131
Type:
ACT20P-VI3-VO3-S
Version:
Analogue isolating amplifier, Input : -10…0…+10 V, Output : -10…0…+10 V, Signal converter/isolator
Type of connection:
Screw connection
Order No.:
7760054306
Type:
ACT20P-VM-AO-S
Version:
Analogue isolating amplifier, Input : AC/DC voltage, 0...600 V DC, 0…440 V AC, Output : 0-10 V, 0(4)-20 mA, Signal converter/isolator
Type of connection:
PUSH IN
Order No.:
7760054360
Type:
ACT20P-VM-AO-P
Version:
Analogue isolating amplifier, Input : AC/DC voltage, 0...600 V DC, 0…440 V AC, Output : 0-10 V, 0(4)-20 mA, Signal converter/isolator
Version
Analogue isolating amplifier, Input : 0(4)-20 mA, Output : 0(4)-20 mA, Voltage supply also via CH20M rail bus, HART®
Order No.
2514620000
Type
ACT20P-CI-CO-P-P
GTIN (EAN)
4050118535198
Qty.
1 pc(s).
Depth
113.7 mm
Depth (inches)
4.476 inch
Height
127.1 mm
Height (inches)
5.004 inch
Width
12.5 mm
Width (inches)
0.492 inch
Net weight
140 g
Operating temperature
-20 °C...60 °C
Humidity at operating temperature
0...95 % (no condensation)
SIL in compliance with IEC 61508
None
RoHS Compliance Status
Compliant with exemption
RoHS Exemption (if applicable/known)
7a, 7cI
REACH SVHC
Lead 7439-92-1
SCIP
2f6dd957-421a-46db-a0c2-cf1609156924
Input current
0...20 mA, 4…20mA
Input signal
HART signal® bidirectional
Number of inputs
1
Sensor
2-wire transmitter (without own power supply), 3-wire sensor, 4- wire sensor (with own power supply)
Sensor supply
> 17 V DC at 20 mA
Voltage drop
≤ 1 V
Load impedance current
≤ 550 Ω
Number of outputs
1
Output current
0…20 mA (if input: 0…20 mA), 4…20 mA (if input: 4…20 mA), HART® digital signal
Type
active, connected control must be passive
Max. switching voltage, AC
0 V
Max. switching voltage, DC
0 V
Rated switching current
0.1 A
Accuracy
<0.1 % of end value
Configuration
none
Current consumption
≤60 mA (24V power supply, 20mA output)
Galvanic isolation
3-way isolator, between input ⁄ output ⁄ supply
Nominal power consumption
2 VA
Operating altitude
≤ 2000 m
Protection degree
IP20
Rail
TS 35
Step response time
≤ 0,5 ms
Temperature coefficient
80 ppm/K
Type of signal forwarding according to HART®
unchanged
Voltage supply
20…30 V at terminal or via CH20M rail bus
EMC standards
EN 61326-1, EN 61000-6-2, EN 61000-6-4
Galvanic isolation
3-way isolator, between input ⁄ output ⁄ supply
Impulse withstand voltage
4 kV (1.2/50 µs)
Insulation voltage
2 kV inputs / outputs / power supply
Pollution severity
2
Surge voltage category
III
Test voltage
0.3 kV
Marking
II 3 G Ex ec IIC T5 Gc
Type of connection
PUSH IN
Tightening torque, min.
0.4 Nm
Tightening torque, max.
0.6 Nm
Clamping range, rated connection
2.5 mm²
Clamping range, min.
0.5 mm²
Clamping range, max.
2.5 mm²
Wire connection cross section AWG, min.
AWG 26
Wire connection cross section AWG, max.
AWG 14
Wire cross-section, solid, min.
0.2 mm²
Wire cross-section, solid, max.
2.5 mm²
Wire connection cross section, finely stranded, min.
0.5 mm²
Wire connection cross section, finely stranded, max.
2.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.
0.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.
2.5 mm²
Product information
The non-adjustable DC isolating amplifier ACT20P-CI-CO isolates analogue standard current signals from a power source or from a 2- or 3-wire sensor. An analogue input current signal is linearly converted into an analogue output current signal and is galvanically isolated. The power supply is galvanically isolated from the input and output (3-way isolation).
Properties
HART-compatible for 0.5 - 2.5 kHz
The active or passive mA signal inputs are fully galvanically isolated.
Operating status display on a front panel LED
Galvanic 3-way isolation between input, output and supply.
ETIM 6.0
EC002653
ETIM 7.0
EC002653
ETIM 8.0
EC002653
ETIM 9.0
EC002653
ECLASS 9.0
27-21-01-20
ECLASS 9.1
27-21-01-20
ECLASS 10.0
27-21-01-20
ECLASS 11.0
27-21-01-20
ECLASS 12.0
27-21-01-20
ECLASS 13.0
27-21-01-20
ECLASS 14.0
27-21-01-20
Approvals
ROHS
Conform
UL File Number Search
UL Website
Certificate no. (cULus)
E469563
Certificate no. (cULusEX)
E338066
Type of connection:
Screw connection
Order No.:
7760054114
Type:
ACT20P-CI-CO-S
Version:
Analogue isolating amplifier, Input : 0(4)-20 mA, Output : 0(4)-20 mA, Signal converter/isolator, HART®
Type of connection:
PUSH IN
Order No.:
2489680000
Type:
ACT20P-CI-CO-P
Version:
Analogue isolating amplifier, Input : 0(4)-20 mA, Output : 0(4)-20 mA, Signal converter/isolator, HART®
Type of connection:
Screw connection
Order No.:
1506200000
Type:
ACT20P-CI-CO-P-S
Version:
Analogue isolating amplifier, Input : 0(4)-20 mA, Output : 0(4)-20 mA, Voltage supply also via CH20M rail bus, HART®
Type of connection:
Screw connection
Order No.:
7760054117
Type:
ACT20P-2CI-2CO-12-S
Version:
Analogue isolating amplifier, Input : 2 x 0(4) - 20 mA, Output : 2 x 4-20 mA, Signal converter/isolator, HART®
Type of connection:
PUSH IN
Order No.:
2489730000
Type:
ACT20P-2CI-2CO-12-P
Version:
Analogue isolating amplifier, Input : 2 x 0(4) - 20 mA, Output : 2 x 4-20 mA, Signal converter/isolator, HART®
Type of connection:
PUSH IN
Order No.:
2514650000
Type:
ACT20P-2CI-2CO-12-P-P
Version:
Analogue isolating amplifier, Input : 2 x 0(4) - 20 mA, Output : 0(4)-20 mA, Voltage supply also via CH20M rail bus, HART®
Type of connection:
Screw connection
Order No.:
1506210000
Type:
ACT20P-2CI-2CO-12P-S
Version:
Analogue isolating amplifier, Input : 2 x 0(4) - 20 mA, Output : 0(4)-20 mA, Voltage supply also via CH20M rail bus, HART®
Type of connection:
Screw connection
Order No.:
1540010000
Type:
ACT20P-CI-VO-S
Version:
Analogue isolating amplifier, Input : 0(4)-20 mA, Output : 0-10 V, Signal converter/isolator
Type of connection:
PUSH IN
Order No.:
2489740000
Type:
ACT20P-CI-VO-P
Version:
Analogue isolating amplifier, Input : 0(4)-20 mA, Output : 0-10 V, Signal converter/isolator
Type of connection:
Screw connection
Order No.:
1537750000
Type:
ACT20P-CI-VO-P-S
Version:
Analogue isolating amplifier, Input : 0(4)-20 mA, Output : 0-10 V, Voltage supply also via CH20M rail bus, Signal converter/isolator
Type of connection:
PUSH IN
Order No.:
2514640000
Type:
ACT20P-CI-VO-P-P
Version:
Analogue isolating amplifier, Input : 0(4)-20 mA, Output : 0-10 V, Voltage supply also via CH20M rail bus, Signal converter/isolator
Type of connection:
Screw connection
Order No.:
7760054131
Type:
ACT20P-VI3-VO3-S
Version:
Analogue isolating amplifier, Input : -10…0…+10 V, Output : -10…0…+10 V, Signal converter/isolator
Type of connection:
Screw connection
Order No.:
7760054306
Type:
ACT20P-VM-AO-S
Version:
Analogue isolating amplifier, Input : AC/DC voltage, 0...600 V DC, 0…440 V AC, Output : 0-10 V, 0(4)-20 mA, Signal converter/isolator
Type of connection:
PUSH IN
Order No.:
7760054360
Type:
ACT20P-VM-AO-P
Version:
Analogue isolating amplifier, Input : AC/DC voltage, 0...600 V DC, 0…440 V AC, Output : 0-10 V, 0(4)-20 mA, Signal converter/isolator
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.