Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Analogue Signal Conditioning
Power Supplies
Electronics Housings
Lightning and Surge Protection
e-mobility
Photovoltaics
Fieldbus Distributors
Network-compatible current measuring transducers ACT20C
intrinsically safe signal converter - ACT20X
signal converter and process monitoring - ACT20P
Space-saving signal converter - ACT20M
Signal converter in terminal block format - MCZ
Compact standard signal isolators - PicoPak
Process monitoring displays
Analogue-digital / digital-analogue converter
Signal - & serial interface converter– WAVESERIES
Configuration software
Accessories
Signal converters
Passive isolator
Signal splitter
Temperature transducer
Measuring and monitoring relay
Current measuring transducer
Bridge measuring transducer
Frequency converters
Universal
ACT20P-PRO-FI-AO-DOS-P
Preliminary product data!Product currently not yet available
General ordering data
Version
Analogue signal converter, Frequency, I/U universal, Relay
Order No.
2490020000
Type
ACT20P-PRO-FI-AO-DOS-P
GTIN (EAN)
4050118500455
Qty.
1 pc(s).
Dimensions and weights
Depth
113.7 mm
Depth (inches)
4.476 inch
Height
117.2 mm
Height (inches)
4.614 inch
Width
12.5 mm
Width (inches)
0.492 inch
Net weight
999 g
Temperatures
Storage temperature
-40 °C...85 °C
Operating temperature
-40 °C...60 °C
Humidity
0...95 % (no condensation)
Probability of failure
SIL in compliance with IEC 61508
None
Environmental Product Compliance
REACH SVHC
Lead 7439-92-1
SCIP
2f6dd957-421a-46db-a0c2-cf1609156924
Input
Input frequency
0,01 Hz…200 kHz, Treshold current (NAMUR): ≥1.65 mA, Hysterisis level: ≥0.2 mA
Input voltage
Threshold voltage (NPN / PNP Sensor): 3 V...43.5 V (configurable), Hysterisis level: ≥0.5 V
Sensor
NPN/PNP sensor, NAMUR sensor, according to EN60947-5-6, Mechanical switch
Sensor supply
18 V ±15 %, 8.2 V ±15% (@ NAMUR sensor)
Output (digital)
Alarm function
configurable, Top and bottom limit values, window range, Short circuit at input, Alarm delay: 0…10 s, Hysteresis: 10 V
Number of digital outputs
1
Rated switching current
100 mA
Rated switching voltage
24 VDC ±30%
Switch-on delay
0...180 s
Type
NPN-Transitor, Switching frequency 5 kHz
Output (analogue)
Load resistance current
≤ 600 Ω
Load resistance voltage
> 1 kΩ (60 VAC <Uin <230 VAC), > 5 kΩ (24 VAC <Uin <60 VAC)
Number of analogue outputs
1
Output current
-20…+20 mA, ± 10mA, 0(4)...20 mA
Output voltage
0...5 V, 0(1)...5 V, 0(2)...10 V, -5…+5 V, -10...+10 V
Signal output
direct or inverted
Transmit function
Linear, x1/2 , x3/2 , x5/2 or user-defined curve (101 points), direct or inverted
Type (analogue output)
Voltage and current output (configurable)
General data
Accuracy
<±0.1 % of span
Configuration
with push-buttons and display
Long-term drift
≤±0.05% of the measurement range / year
Power consumption
≤ 2.6 W
Protection degree
IP20
Rail
TS 35
Step response time
40 ms + period
Temperature coefficient
≤ 0.02 % / °C, ≤ 100 ppm/K of final value
Voltage supply
24…230 V DC ±15%, 24…230 V AC ±15% @48…62 Hz
Insulation coordination
EMC standards
EN 61326-1
Impulse withstand voltage
5 kV (1.2/50 µs)
Insulation voltage
4 kVeff / 1 min.
Pollution severity
2
Rated voltage
600 V
Surge voltage category
II
Safety-related basic specifications
Safety category
SIL 2
Connection data
Type of connection
PUSH IN
Classifications
ETIM 6.0
EC002918
ETIM 7.0
EC002918
ETIM 8.0
EC002918
ETIM 9.0
EC002918
ECLASS 9.0
27-21-01-28
ECLASS 9.1
27-21-01-28
ECLASS 10.0
27-21-01-28
ECLASS 11.0
27-21-01-28
ECLASS 12.0
27-21-01-28
ECLASS 13.0
27-21-01-28
Approvals
Approvals
ROHS
Conform
Type of connection:
Screw connection
Order No.:
2447940000
Type:
ACT20P-PRO-FI-AO-DO-S
Version:
Frequency signal converter, Limit value monitoring, Frequency, PWM, analogue V / mA, Transistor (Alarm)
Type of connection:
PUSH IN
Order No.:
2447950000
Type:
ACT20P-PRO-FI-AO-DO-P
Version:
Frequency signal converter, Limit value monitoring, Frequency, PWM, analogue V / mA, Transistor (Alarm)
Version
Analogue signal converter, Frequency, I/U universal, Relay
Order No.
2490020000
Type
ACT20P-PRO-FI-AO-DOS-P
GTIN (EAN)
4050118500455
Qty.
1 pc(s).
Depth
113.7 mm
Depth (inches)
4.476 inch
Height
117.2 mm
Height (inches)
4.614 inch
Width
12.5 mm
Width (inches)
0.492 inch
Net weight
999 g
Storage temperature
-40 °C...85 °C
Operating temperature
-40 °C...60 °C
Humidity
0...95 % (no condensation)
SIL in compliance with IEC 61508
None
REACH SVHC
Lead 7439-92-1
SCIP
2f6dd957-421a-46db-a0c2-cf1609156924
Input frequency
0,01 Hz…200 kHz, Treshold current (NAMUR): ≥1.65 mA, Hysterisis level: ≥0.2 mA
Input voltage
Threshold voltage (NPN / PNP Sensor): 3 V...43.5 V (configurable), Hysterisis level: ≥0.5 V
Sensor
NPN/PNP sensor, NAMUR sensor, according to EN60947-5-6, Mechanical switch
Sensor supply
18 V ±15 %, 8.2 V ±15% (@ NAMUR sensor)
Alarm function
configurable, Top and bottom limit values, window range, Short circuit at input, Alarm delay: 0…10 s, Hysteresis: 10 V
Number of digital outputs
1
Rated switching current
100 mA
Rated switching voltage
24 VDC ±30%
Switch-on delay
0...180 s
Type
NPN-Transitor, Switching frequency 5 kHz
Load resistance current
≤ 600 Ω
Load resistance voltage
> 1 kΩ (60 VAC <Uin <230 VAC), > 5 kΩ (24 VAC <Uin <60 VAC)
Number of analogue outputs
1
Output current
-20…+20 mA, ± 10mA, 0(4)...20 mA
Output voltage
0...5 V, 0(1)...5 V, 0(2)...10 V, -5…+5 V, -10...+10 V
Signal output
direct or inverted
Transmit function
Linear, x1/2 , x3/2 , x5/2 or user-defined curve (101 points), direct or inverted
Type (analogue output)
Voltage and current output (configurable)
Accuracy
<±0.1 % of span
Configuration
with push-buttons and display
Long-term drift
≤±0.05% of the measurement range / year
Power consumption
≤ 2.6 W
Protection degree
IP20
Rail
TS 35
Step response time
40 ms + period
Temperature coefficient
≤ 0.02 % / °C, ≤ 100 ppm/K of final value
Voltage supply
24…230 V DC ±15%, 24…230 V AC ±15% @48…62 Hz
EMC standards
EN 61326-1
Impulse withstand voltage
5 kV (1.2/50 µs)
Insulation voltage
4 kVeff / 1 min.
Pollution severity
2
Rated voltage
600 V
Surge voltage category
II
Type of connection
PUSH IN
ETIM 6.0
EC002918
ETIM 7.0
EC002918
ETIM 8.0
EC002918
ETIM 9.0
EC002918
ECLASS 9.0
27-21-01-28
ECLASS 9.1
27-21-01-28
ECLASS 10.0
27-21-01-28
ECLASS 11.0
27-21-01-28
ECLASS 12.0
27-21-01-28
ECLASS 13.0
27-21-01-28
Approvals
ROHS
Conform
Type of connection:
Screw connection
Order No.:
2447940000
Type:
ACT20P-PRO-FI-AO-DO-S
Version:
Frequency signal converter, Limit value monitoring, Frequency, PWM, analogue V / mA, Transistor (Alarm)
Type of connection:
PUSH IN
Order No.:
2447950000
Type:
ACT20P-PRO-FI-AO-DO-P
Version:
Frequency signal converter, Limit value monitoring, Frequency, PWM, analogue V / mA, Transistor (Alarm)
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.