Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Controls
I/O Systems
Industrial Ethernet
Touch Panels
Engineering and Visualisation Tools
Measuring and Monitoring Systems
I/O System IP20 - u-remote
I/O System IP67 - u-remote
Field bus coupler
Modules
Accessories
Digital input modules
Digital output modules
Digital input and output modules
Pulse width modulation and stepper motor modules
Analogue input modules
Temperature modules and potentiometer input module
Strain gauge module
Power measurement module
Analogue output modules
Digital counter- and communication- modules
Safe I/O modules and safe power-feed modules
Power-feed modules
Potential distribution modules
Replacement parts
General ordering data
Version
Remote I/O module, IP20, Analog signals, Temperature, RTD
Order No.
2456540000
Type
UR20-4AI-RTD-HP-DIAG
GTIN (EAN)
4050118471717
Qty.
1 pc(s).
Dimensions and weights
Depth
76 mm
Depth (inches)
2.992 inch
Height
120 mm
Height (inches)
4.724 inch
Width
11.5 mm
Width (inches)
0.453 inch
Mounting dimension - height
128 mm
Net weight
88 g
Temperatures
Storage temperature
-40 °C ... +85 °C
Operating temperature
-20 °C ... +60 °C
Environmental Product Compliance
REACH SVHC
Lead 7439-92-1
SCIP
82327f13-cd27-455a-ab5b-a62e1996dcf8
RoHS Compliance Status
Compliant with exemption
RoHS Exemption (if applicable/known)
7a, 7cI
analogue inputs
Accuracy
max. 0,6 K for Measurement range Pt100 (-200 … +250 °C), max. 0,2 % FSR for Pt sensors and resistance measurement (-200 … +250 °C), max. 0,3 % FSR for Ni sensors, max. 0,6 % FSR for Cu10
Conversion time
adjustable, 36…240 ms
Individual channel diagnosis
Yes
Measured temperature value, max.
850 °C
Measured temperature value, min.
-200 °C
Module diagnosis
Yes
Number of analogue inputs
4
Resolution
16 Bit
Reverse polarity protection
Yes
Sensor connection
2-wire, 3-wire, 4-wire
Temperature coefficient
≤ 50 ppm/K
Type
Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni 200, Ni500, Ni1000, Cu10, 40Ω, 80Ω, 150Ω, 300Ω, 500Ω,1kΩ, 2kΩ,4kΩ
Connection data
Type of connection
PUSH IN
Wire connection cross section, finely stranded, max.
1.5 mm²
Wire connection cross section, finely stranded, min.
0.14 mm²
Wire cross-section, finely stranded, max. (AWG)
AWG 16
Wire cross-section, finely stranded, min. (AWG)
AWG 26
Wire cross-section, solid, max.
1.5 mm²
Wire cross-section, solid, max. (AWG)
AWG 16
Wire cross-section, solid, min.
0.14 mm²
Wire cross-section, solid, min. (AWG)
AWG 26
General data
Air humidity (operation)
10% to 95%, non-condensing as per DIN EN 61131-2
Air humidity (storage)
10% to 95%, non-condensing as per DIN EN 61131-2
Air humidity (transport)
10% to 95%, non-condensing as per DIN EN 61131-2
Air pressure (operation)
≥ 795 hPa (height ≤ 2000 m) as per DIN EN 61131-2
Air pressure (storage)
1013 hPa (height 0 m) to 700 hPa (height 3000 m) as per DIN EN 61131-2
Air pressure (transport)
1013 hPa (height 0 m) to 700 hPa (height 3000 m) as per DIN EN 61131-2
Pollution severity
2
Rail
TS 35
Shock
15 g over 11 ms, half sinus wave, acc. to IEC 60068-2-27
Surge voltage category
II
Test voltage
500 V
UL 94 flammability rating
V-0
Vibration resistance
5 Hz ≤ f ≤ 8.4 Hz: 3.5-mm amplitude as per IEC 60068-2-6, 8.4 Hz ≤ f ≤ 150 Hz: 1 g acceleration as per IEC 60068-2-6
Power supply
Current consumption from IIN (the respective power segment)
< 20 mA
Current consumption from Isys , typ.
8 mA
Reverse polarity protection
Yes
Voltage supply
24 V DC +20 %/ -15 %, via the system bus
System data
Field bus protocol
CANopen, DeviceNet, EtherCAT, EtherNet/IP, Modbus/TCP, PROFINET IRT, PROFIBUS DP-V1, POWERLINK
Galvanic isolation
500 V DC between the current paths
Interface
u-remote system bus
Module type
Temperature module
Transmission speed of system bus, max.
48 Mbit
Downloads
Approval/Certificate/Document of Conformity
Engineering Data
Eplan Data Portal
Eplan data
CADENAS eCATALOG
CAX data
Product Change Notification
Software
User Documentation
Catalogues
Catalogues in PDF-format
Classifications
ETIM 6.0
EC001596
ETIM 7.0
EC001596
ETIM 8.0
EC001596
ETIM 9.0
EC001596
ECLASS 9.0
27-24-26-01
ECLASS 9.1
27-24-26-01
ECLASS 10.0
27-24-26-01
ECLASS 11.0
27-24-26-01
ECLASS 12.0
27-24-26-01
ECLASS 13.0
27-24-26-01
Order No.:
1315700000
Type:
UR20-4AI-RTD-DIAG
Version:
Remote I/O module, IP20, Analog signals, Temperature, RTD
Order No.:
2555940000
Type:
UR20-8AI-RTD-DIAG-2W
Version:
Remote I/O module, IP20, Analog signals, Temperature, RTD
Order No.:
1315710000
Type:
UR20-4AI-TC-DIAG
Version:
Remote I/O module, IP20, Analog signals, Temperature, TC
Order No.:
2001670000
Type:
UR20-4AI-R-HS-16-DIAG
Version:
Remote I/O module, IP20, 4-channel, Analog signals, Input, 16 Bit
Version
Remote I/O module, IP20, Analog signals, Temperature, RTD
Order No.
2456540000
Type
UR20-4AI-RTD-HP-DIAG
GTIN (EAN)
4050118471717
Qty.
1 pc(s).
Depth
76 mm
Depth (inches)
2.992 inch
Height
120 mm
Height (inches)
4.724 inch
Width
11.5 mm
Width (inches)
0.453 inch
Mounting dimension - height
128 mm
Net weight
88 g
Storage temperature
-40 °C ... +85 °C
Operating temperature
-20 °C ... +60 °C
REACH SVHC
Lead 7439-92-1
SCIP
82327f13-cd27-455a-ab5b-a62e1996dcf8
RoHS Compliance Status
Compliant with exemption
RoHS Exemption (if applicable/known)
7a, 7cI
Accuracy
max. 0,6 K for Measurement range Pt100 (-200 … +250 °C), max. 0,2 % FSR for Pt sensors and resistance measurement (-200 … +250 °C), max. 0,3 % FSR for Ni sensors, max. 0,6 % FSR for Cu10
Conversion time
adjustable, 36…240 ms
Individual channel diagnosis
Yes
Measured temperature value, max.
850 °C
Measured temperature value, min.
-200 °C
Module diagnosis
Yes
Number of analogue inputs
4
Resolution
16 Bit
Reverse polarity protection
Yes
Sensor connection
2-wire, 3-wire, 4-wire
Temperature coefficient
≤ 50 ppm/K
Type
Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni 200, Ni500, Ni1000, Cu10, 40Ω, 80Ω, 150Ω, 300Ω, 500Ω,1kΩ, 2kΩ,4kΩ
Type of connection
PUSH IN
Wire connection cross section, finely stranded, max.
1.5 mm²
Wire connection cross section, finely stranded, min.
0.14 mm²
Wire cross-section, finely stranded, max. (AWG)
AWG 16
Wire cross-section, finely stranded, min. (AWG)
AWG 26
Wire cross-section, solid, max.
1.5 mm²
Wire cross-section, solid, max. (AWG)
AWG 16
Wire cross-section, solid, min.
0.14 mm²
Wire cross-section, solid, min. (AWG)
AWG 26
Air humidity (operation)
10% to 95%, non-condensing as per DIN EN 61131-2
Air humidity (storage)
10% to 95%, non-condensing as per DIN EN 61131-2
Air humidity (transport)
10% to 95%, non-condensing as per DIN EN 61131-2
Air pressure (operation)
≥ 795 hPa (height ≤ 2000 m) as per DIN EN 61131-2
Air pressure (storage)
1013 hPa (height 0 m) to 700 hPa (height 3000 m) as per DIN EN 61131-2
Air pressure (transport)
1013 hPa (height 0 m) to 700 hPa (height 3000 m) as per DIN EN 61131-2
Pollution severity
2
Rail
TS 35
Shock
15 g over 11 ms, half sinus wave, acc. to IEC 60068-2-27
Surge voltage category
II
Test voltage
500 V
UL 94 flammability rating
V-0
Vibration resistance
5 Hz ≤ f ≤ 8.4 Hz: 3.5-mm amplitude as per IEC 60068-2-6, 8.4 Hz ≤ f ≤ 150 Hz: 1 g acceleration as per IEC 60068-2-6
Current consumption from IIN (the respective power segment)
< 20 mA
Current consumption from Isys , typ.
8 mA
Reverse polarity protection
Yes
Voltage supply
24 V DC +20 %/ -15 %, via the system bus
Field bus protocol
CANopen, DeviceNet, EtherCAT, EtherNet/IP, Modbus/TCP, PROFINET IRT, PROFIBUS DP-V1, POWERLINK
Galvanic isolation
500 V DC between the current paths
Interface
u-remote system bus
Module type
Temperature module
Transmission speed of system bus, max.
48 Mbit
ETIM 6.0
EC001596
ETIM 7.0
EC001596
ETIM 8.0
EC001596
ETIM 9.0
EC001596
ECLASS 9.0
27-24-26-01
ECLASS 9.1
27-24-26-01
ECLASS 10.0
27-24-26-01
ECLASS 11.0
27-24-26-01
ECLASS 12.0
27-24-26-01
ECLASS 13.0
27-24-26-01
Approvals
ROHS
Conform
UL File Number Search
UL Website
Certificate no. (cULus)
E141197
Certificate no. (cULusEX)
E223527
Order No.:
1315700000
Type:
UR20-4AI-RTD-DIAG
Version:
Remote I/O module, IP20, Analog signals, Temperature, RTD
Order No.:
2555940000
Type:
UR20-8AI-RTD-DIAG-2W
Version:
Remote I/O module, IP20, Analog signals, Temperature, RTD
Order No.:
1315710000
Type:
UR20-4AI-TC-DIAG
Version:
Remote I/O module, IP20, Analog signals, Temperature, TC
Order No.:
2001670000
Type:
UR20-4AI-R-HS-16-DIAG
Version:
Remote I/O module, IP20, 4-channel, Analog signals, Input, 16 Bit
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.