Network-compatible current measuring transducers ACT20C
intrinsically safe signal converter - ACT20X
signal converter and process monitoring - ACT20P
Space-saving signal converter - ACT20M
Signal converter in terminal block format - MCZ
Compact standard signal isolators - PicoPak
Process monitoring displays
Analogue-digital / digital-analogue converter
Signal - & serial interface converter– WAVESERIES
Configuration software
Accessories
HART® transparent repeater
HART® transparent driver
Temperature & mA converter
Pulse isolator with relay output
Pulse isolator with transistor output
Solenoid valve switch & alarm transmitter
Universal converter
General ordering data
Version
EX signal isolating converter, Ex-input: I,ϑ, Safe-output: 4-20mA, 1-channel
Order No.
2456180000
Type
ACT20X-HTI-SAO-P
GTIN (EAN)
4050118471595
Qty.
1 pc(s).
Dimensions and weights
Depth
114.6 mm
Depth (inches)
4.512 inch
Height
127.3 mm
Height (inches)
5.012 inch
Width
22.5 mm
Width (inches)
0.886 inch
Net weight
178 g
Temperatures
Storage temperature
-20 °C...85 °C
Operating temperature
-20 °C...60 °C
Humidity
0...95 % (no condensation)
Probability of failure
SIL PAPER
SIL certificate
SIL in compliance with IEC 61508
2
Environmental Product Compliance
REACH SVHC
Lead 7439-92-1
SCIP
2f6dd957-421a-46db-a0c2-cf1609156924
RoHS Compliance Status
Compliant with exemption
RoHS Exemption (if applicable/known)
7a, 7cI
Assembling
Mounting position
horizontal or vertical
Rail
TS 35
Type of mounting
DIN rail
Input EX
Input current
0...20 mA, 4…20mA
Input resistance, current
20 Ω + PTC 50 Ω
Line resistance in measuring circuit
≤ 50 Ω
Sensor
2-/3-/4-wire, RTD: PT10, PT20, PT50, PT100, PT250, PT300, PT400, PT500, PT1000, Ni50, Ni100, Ni120, Ni1000, Thermocouples: B, E, J, K, N, R, S, T ; in compliance with IEC 60584-1 and L, U in compliance with DIN43710
Temperature input range
Configurable, PT100: -200…+850 °C, PT200: -200…+850 °C, PT1000: -200…+850 °C, NI100: -60°C…+250 °C, Ni120: -80 °C…+320 °C, NI1000: -60°C…+250 °C, B: +100…+1820 °C, E: (-100…+1000 °C), J: (-100…+1200 °C), K: (-180…+1372 °C), L: (-200…+900 °C), N: (-180…+1300 °C), R: (-50…+1760 °C), S: (-50…+1760 °C), T: (-200…+400 °C), U: (-200…+600 °C), W3: (0…+2300 °C), W5: (0…+2300 °C), LR: (-200…+800 °C)
Type
intrinsically safe circuit, RTD, TC, DC (mA)
Output
Influence of load resistance
≤ 0.01% of span / 100 Ω
Load impedance current
≤ 600 Ω
Output current
0…23 mA, configurable: 0…20 / 4…20 / 20…0 / 20…4 mA, configurable downscale (3.5 mA) ⁄ upscale (23 mA) @ error
Output signal limit
3.8…20.5 mA / 0…20.5 mA (dependent on range)
Type
active (as current source) or passive (as current sink)
Alarm output
Alarm function
Line interruption at the input, Short circuit at input, No supply voltage, Device error
Continuous current
≤ 0.5 A AC / 0.3 A DC (safe zone), ≤ 0,5 A AC / 1 A DC (zone 2)
Nominal switching voltage
≤ 125 V AC / 110 V DC (safe area) ≤ 32 V AC / 32 V DC (zone 2)
Power rating
≤ 62.5 VA / 32 W (safe area) ≤ 16 VA / 32 W (Zone 2)
Type
Status relay, 1 NC (voltage-free)
General specifications
Configuration
With FDT/DTM software, Requires configuration adapter 8978580000 CBX200 USB
Humidity
0...95 % (no condensation)
Operating altitude
≤ 2000 m
Power consumption
≤ 0.8 W
Protection degree
IP20
Step response time
≤ 400 ms (with current), ≤ 1 s (with temperature)
Type of connection
PUSH IN
Voltage supply
19.2…31.2 V DC
Insulation coordination
EMC standards
EN 61326-1
Insulation voltage
2.6 kV (input / output)
Rated voltage
300 V
Standards
EN 61010-1
Data for Ex applications (ATEX)
Current I0
18.4 mA
Installation location
Device installed in safe area, zone 2
Marking
II (1) G [Ex ia Ga] IIC/IIB/IIA, II (1) D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I
Power P0
40 mW
Voltage U0
8.7 V DC
Safety-related basic specifications
Description of the "safe state"
analogue Output ≤ 3.6 mA or output ≥ 21 mA
Device type
B
Diagnostic test interval
30 s
Tproof
3 a
Total failure rate for safe detected failures (λSD )
0 FIT
Hardware fault tolerance (HFT)
0
Safety category
SIL 2
Safe Failure Fraction (SFF)
90 %
Mean Time To Repair (MTTR)
24 h
Total failure rate for safe undetected failures (λSU )
234 FIT
Total failure rate for dangerous detected failures (λDD )
367 FIT
Total failure rate for dangerous undetected failures (λDU )
61 FIT
Probability of outage PFH
6.1 x 10-8 h-1
Demand mode
High
Demand rate
3,000 s
Demand response time
Signal input: <0.5 s (opto output), Temperature input: <1.1 s (opto output)
Safety-related specifications Low demand mode
Average Probability of Failure on Demand (PFDavg )
3.96 x 10-4 (Tproof = 1 year), 6.5 x 10-4 (Tproof = 2 years), 1.41 x 10-4 (Tproof = 5 years)
Connection data
Type of connection
PUSH IN
Wire connection cross section AWG, min.
AWG 26
Wire connection cross section AWG, max.
AWG 14
Wire cross-section, solid, min.
0.2 mm²
Wire cross-section, solid, max.
2.5 mm²
Wire connection cross section, finely stranded, min.
0.2 mm²
Wire connection cross section, finely stranded, max.
2.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.
0.2 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.
2.5 mm²
Guarantee
Time interval
3 years
Classifications
ETIM 6.0
EC002919
ETIM 7.0
EC002919
ETIM 8.0
EC002919
ETIM 9.0
EC002919
ECLASS 9.0
27-21-01-29
ECLASS 9.1
27-21-01-29
ECLASS 10.0
27-21-01-29
ECLASS 11.0
27-21-01-29
ECLASS 12.0
27-21-01-29
ECLASS 13.0
27-21-01-29
ECLASS 14.0
27-21-01-29
Order No.:
8965470000
Type of connection:
Screw connection
Type:
ACT20X-HTI-SAO-S
Version:
EX signal isolating converter, Ex-input: I,ϑ, Safe-output: 4-20mA, 1-channel
Order No.:
8965480000
Type of connection:
Screw connection
Type:
ACT20X-2HTI-2SAO-S
Version:
EX signal isolating converter, Ex-input: I,ϑ, Safe-output: 4-20mA, 2-channel
Order No.:
2456190000
Type of connection:
PUSH IN
Type:
ACT20X-2HTI-2SAO-P
Version:
EX signal isolating converter, Ex-input: I,ϑ, Safe-output: 4-20mA, 2-channel
Version
EX signal isolating converter, Ex-input: I,ϑ, Safe-output: 4-20mA, 1-channel
Order No.
2456180000
Type
ACT20X-HTI-SAO-P
GTIN (EAN)
4050118471595
Qty.
1 pc(s).
Depth
114.6 mm
Depth (inches)
4.512 inch
Height
127.3 mm
Height (inches)
5.012 inch
Width
22.5 mm
Width (inches)
0.886 inch
Net weight
178 g
Storage temperature
-20 °C...85 °C
Operating temperature
-20 °C...60 °C
Humidity
0...95 % (no condensation)
REACH SVHC
Lead 7439-92-1
SCIP
2f6dd957-421a-46db-a0c2-cf1609156924
RoHS Compliance Status
Compliant with exemption
RoHS Exemption (if applicable/known)
7a, 7cI
Mounting position
horizontal or vertical
Rail
TS 35
Type of mounting
DIN rail
Input current
0...20 mA, 4…20mA
Input resistance, current
20 Ω + PTC 50 Ω
Line resistance in measuring circuit
≤ 50 Ω
Sensor
2-/3-/4-wire, RTD: PT10, PT20, PT50, PT100, PT250, PT300, PT400, PT500, PT1000, Ni50, Ni100, Ni120, Ni1000, Thermocouples: B, E, J, K, N, R, S, T ; in compliance with IEC 60584-1 and L, U in compliance with DIN43710
Temperature input range
Configurable, PT100: -200…+850 °C, PT200: -200…+850 °C, PT1000: -200…+850 °C, NI100: -60°C…+250 °C, Ni120: -80 °C…+320 °C, NI1000: -60°C…+250 °C, B: +100…+1820 °C, E: (-100…+1000 °C), J: (-100…+1200 °C), K: (-180…+1372 °C), L: (-200…+900 °C), N: (-180…+1300 °C), R: (-50…+1760 °C), S: (-50…+1760 °C), T: (-200…+400 °C), U: (-200…+600 °C), W3: (0…+2300 °C), W5: (0…+2300 °C), LR: (-200…+800 °C)
Type
intrinsically safe circuit, RTD, TC, DC (mA)
Influence of load resistance
≤ 0.01% of span / 100 Ω
Load impedance current
≤ 600 Ω
Output current
0…23 mA, configurable: 0…20 / 4…20 / 20…0 / 20…4 mA, configurable downscale (3.5 mA) ⁄ upscale (23 mA) @ error
Output signal limit
3.8…20.5 mA / 0…20.5 mA (dependent on range)
Type
active (as current source) or passive (as current sink)
Alarm function
Line interruption at the input, Short circuit at input, No supply voltage, Device error
Continuous current
≤ 0.5 A AC / 0.3 A DC (safe zone), ≤ 0,5 A AC / 1 A DC (zone 2)
Nominal switching voltage
≤ 125 V AC / 110 V DC (safe area) ≤ 32 V AC / 32 V DC (zone 2)
Power rating
≤ 62.5 VA / 32 W (safe area) ≤ 16 VA / 32 W (Zone 2)
Type
Status relay, 1 NC (voltage-free)
Configuration
With FDT/DTM software, Requires configuration adapter 8978580000 CBX200 USB
Humidity
0...95 % (no condensation)
Operating altitude
≤ 2000 m
Power consumption
≤ 0.8 W
Protection degree
IP20
Step response time
≤ 400 ms (with current), ≤ 1 s (with temperature)
Type of connection
PUSH IN
Voltage supply
19.2…31.2 V DC
EMC standards
EN 61326-1
Insulation voltage
2.6 kV (input / output)
Rated voltage
300 V
Standards
EN 61010-1
Current I0
18.4 mA
Installation location
Device installed in safe area, zone 2
Marking
II (1) G [Ex ia Ga] IIC/IIB/IIA, II (1) D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I
Power P0
40 mW
Voltage U0
8.7 V DC
Description of the "safe state"
analogue Output ≤ 3.6 mA or output ≥ 21 mA
Device type
B
Diagnostic test interval
30 s
Tproof
3 a
Total failure rate for safe detected failures (λSD )
0 FIT
Hardware fault tolerance (HFT)
0
Safety category
SIL 2
Safe Failure Fraction (SFF)
90 %
Mean Time To Repair (MTTR)
24 h
Total failure rate for safe undetected failures (λSU )
234 FIT
Total failure rate for dangerous detected failures (λDD )
367 FIT
Total failure rate for dangerous undetected failures (λDU )
61 FIT
Probability of outage PFH
6.1 x 10-8 h-1
Demand mode
High
Demand rate
3,000 s
Demand response time
Signal input: <0.5 s (opto output), Temperature input: <1.1 s (opto output)
Average Probability of Failure on Demand (PFDavg )
3.96 x 10-4 (Tproof = 1 year), 6.5 x 10-4 (Tproof = 2 years), 1.41 x 10-4 (Tproof = 5 years)
Type of connection
PUSH IN
Wire connection cross section AWG, min.
AWG 26
Wire connection cross section AWG, max.
AWG 14
Wire cross-section, solid, min.
0.2 mm²
Wire cross-section, solid, max.
2.5 mm²
Wire connection cross section, finely stranded, min.
0.2 mm²
Wire connection cross section, finely stranded, max.
2.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.
0.2 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.
2.5 mm²
ETIM 6.0
EC002919
ETIM 7.0
EC002919
ETIM 8.0
EC002919
ETIM 9.0
EC002919
ECLASS 9.0
27-21-01-29
ECLASS 9.1
27-21-01-29
ECLASS 10.0
27-21-01-29
ECLASS 11.0
27-21-01-29
ECLASS 12.0
27-21-01-29
ECLASS 13.0
27-21-01-29
ECLASS 14.0
27-21-01-29
Approvals
ROHS
Conform
UL File Number Search
UL Website
Certificate no. (cULus)
E337701
Order No.:
8965470000
Type of connection:
Screw connection
Type:
ACT20X-HTI-SAO-S
Version:
EX signal isolating converter, Ex-input: I,ϑ, Safe-output: 4-20mA, 1-channel
Order No.:
8965480000
Type of connection:
Screw connection
Type:
ACT20X-2HTI-2SAO-S
Version:
EX signal isolating converter, Ex-input: I,ϑ, Safe-output: 4-20mA, 2-channel
Order No.:
2456190000
Type of connection:
PUSH IN
Type:
ACT20X-2HTI-2SAO-P
Version:
EX signal isolating converter, Ex-input: I,ϑ, Safe-output: 4-20mA, 2-channel
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.