Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Analogue Signal Conditioning
Power Supplies
Electronics Housings
Lightning and Surge Protection
e-mobility
Photovoltaics
Fieldbus Distributors
Network-compatible current measuring transducers ACT20C
intrinsically safe signal converter - ACT20X
signal converter and process monitoring - ACT20P
Space-saving signal converter - ACT20M
Signal converter in terminal block format - MCZ
Compact standard signal isolators - PicoPak
Process monitoring displays
Analogue-digital / digital-analogue converter
Signal - & serial interface converter– WAVESERIES
Configuration software
Accessories
HART® transparent repeater
HART® transparent driver
Temperature & mA converter
Pulse isolator with relay output
Pulse isolator with transistor output
Solenoid valve switch & alarm transmitter
Universal converter
General ordering data
Version
EX signal isolating converter, Ex-input: 4 - 20 mA, Safe-output: 4-20mA, HART® , 1-channel
Order No.
2456140000
Type
ACT20X-HAI-SAO-P
GTIN (EAN)
4050118471540
Qty.
1 pc(s).
Dimensions and weights
Depth
114.6 mm
Depth (inches)
4.512 inch
Height
127.3 mm
Height (inches)
5.012 inch
Width
22.5 mm
Width (inches)
0.886 inch
Net weight
186 g
Temperatures
Storage temperature
-20 °C...85 °C
Operating temperature
-20 °C...60 °C
Humidity
0...95 % (no condensation)
Probability of failure
SIL PAPER
SIL certificate
SIL in compliance with IEC 61508
2
MTBF
177 a
SFF
80 %
Environmental Product Compliance
REACH SVHC
Lead 7439-92-1
SCIP
2f6dd957-421a-46db-a0c2-cf1609156924
Assembling
Mounting position
horizontal or vertical
Rail
TS 35
Input EX
Input current
4…20mA
Output signal in case of wire break
<1 mA
Residual ripple (current loop)
<7.5 mVeff
Sensor supply
> 16 V DC
Type
intrinsically safe circuit, active (as current source) or passive (as current sink)
Voltage drop not powered
<6 V
Voltage drop powered
<4.5 V
Output
Load impedance current
≤ 600 Ω
Load stability
≤ 0.01 % of end value / 100 Ω
Output current
4...20 mA
Output signal limit
<28 mA
Type
active (as current source) or passive (as current sink)
Alarm output
Alarm function
Signal limit exceeded, Line interruption at the input, No supply voltage, Device error
Continuous current
≤ 0.5 A AC / 0.3 A DC (safe zone), ≤ 0,5 A AC / 1 A DC (zone 2)
Nominal switching voltage
≤ 125 V AC / 110 V DC (safe area) ≤ 32 V AC / 32 V DC (zone 2)
Power rating
≤ 62.5 VA / 32 W (safe area) ≤ 16 VA / 32 W (Zone 2)
Type
Status relay, 1 NC (voltage-free)
General specifications
Accuracy
<0.1% span
Configuration
With FDT/DTM software, Requires configuration adapter 8978580000 CBX200 USB
HART® transparency supported
Yes
Humidity
0...95 % (no condensation)
Power consumption
≤ 1.9 W
Protection degree
IP20
Step response time
≤ 5 ms
Temperature coefficient
<0.01% of span/°C (TU)
Type of connection
PUSH IN
Type of signal forwarding according to HART®
unchanged
Voltage supply
19.2…31.2 V DC
Insulation coordination
EMC standards
EN 61326-1
Insulation voltage
2.6 kV (input / output)
Rated voltage
300 V
Standards
EN 61010-1
Data for Ex applications (ATEX)
Current I0
Current loop 93 mA / externally 10 mA
Installation location
Device installed in safe area, zone 2
Marking
II (1) G [Ex ia Ga] IIC/IIB/IIA, II (1) D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I
Power P0
Current loop 0.65 W / externally 0.1 W
Voltage U0
Current loop 28 V / externally 10 V
Safety-related basic specifications
Description of the "safe state"
analogue Output ≤ 3.6 mA or output ≥ 21 mA
Device type
A
Tproof
5 a
Total failure rate for safe detected failures (λSD )
0 FIT
Hardware fault tolerance (HFT)
0
Safety category
SIL 2
Safe Failure Fraction (SFF)
85 %
Mean Time To Repair (MTTR)
24 h
Total failure rate for safe undetected failures (λSU )
164 FIT
Total failure rate for dangerous detected failures (λDD )
127 FIT
Total failure rate for dangerous undetected failures (λDU )
48 FIT
Probability of outage PFH
4.1 x 10-8 h-1
Demand mode
High
Safety-related specifications Low demand mode
Average Probability of Failure on Demand (PFDavg )
1.92 x 10-4 (Tproof = 1 year), 3.67 x 10-4 (Tproof = 2 years), 8.92 x 10-4 (Tproof = 5 years), additional data in the safety manual
Connection data
Type of connection
PUSH IN
Wire connection cross section AWG, min.
AWG 26
Wire connection cross section AWG, max.
AWG 14
Wire cross-section, solid, min.
0.2 mm²
Wire cross-section, solid, max.
2.5 mm²
Wire connection cross section, finely stranded, min.
0.2 mm²
Wire connection cross section, finely stranded, max.
2.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.
0.2 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.
2.5 mm²
Guarantee
Time interval
3 years
Downloads
Approval/Certificate/Document of Conformity
Engineering Data
CADENAS eCATALOG
CAX data
Software
User Documentation
Catalogues
Catalogues in PDF-format
Classifications
ETIM 6.0
EC002653
ETIM 7.0
EC002653
ETIM 8.0
EC002653
ETIM 9.0
EC002653
ECLASS 9.0
27-21-01-20
ECLASS 9.1
27-21-01-20
ECLASS 10.0
27-21-01-20
ECLASS 11.0
27-21-01-20
ECLASS 12.0
27-21-01-20
ECLASS 13.0
27-21-01-20
Type of connection:
Screw connection
Order No.:
8965430000
Type:
ACT20X-HAI-SAO-S
Version:
EX signal isolating converter, Ex-input: 4 - 20 mA, Safe-output: 4-20mA, HART® , 1-channel
Type of connection:
Screw connection
Order No.:
8965440000
Type:
ACT20X-2HAI-2SAO-S
Version:
EX signal isolating converter, Ex-input: 4 - 20 mA, Safe-output: 4-20mA, HART® , 2-channel
Type of connection:
PUSH IN
Order No.:
2456150000
Type:
ACT20X-2HAI-2SAO-P
Version:
EX signal isolating converter, Ex-input: 4 - 20 mA, Safe-output: 4-20mA, HART® , 2-channel
Version
EX signal isolating converter, Ex-input: 4 - 20 mA, Safe-output: 4-20mA, HART® , 1-channel
Order No.
2456140000
Type
ACT20X-HAI-SAO-P
GTIN (EAN)
4050118471540
Qty.
1 pc(s).
Depth
114.6 mm
Depth (inches)
4.512 inch
Height
127.3 mm
Height (inches)
5.012 inch
Width
22.5 mm
Width (inches)
0.886 inch
Net weight
186 g
Storage temperature
-20 °C...85 °C
Operating temperature
-20 °C...60 °C
Humidity
0...95 % (no condensation)
SIL PAPER
SIL certificate
SIL in compliance with IEC 61508
2
MTBF
177 a
SFF
80 %
REACH SVHC
Lead 7439-92-1
SCIP
2f6dd957-421a-46db-a0c2-cf1609156924
Mounting position
horizontal or vertical
Rail
TS 35
Input current
4…20mA
Output signal in case of wire break
<1 mA
Residual ripple (current loop)
<7.5 mVeff
Sensor supply
> 16 V DC
Type
intrinsically safe circuit, active (as current source) or passive (as current sink)
Voltage drop not powered
<6 V
Voltage drop powered
<4.5 V
Load impedance current
≤ 600 Ω
Load stability
≤ 0.01 % of end value / 100 Ω
Output current
4...20 mA
Output signal limit
<28 mA
Type
active (as current source) or passive (as current sink)
Alarm function
Signal limit exceeded, Line interruption at the input, No supply voltage, Device error
Continuous current
≤ 0.5 A AC / 0.3 A DC (safe zone), ≤ 0,5 A AC / 1 A DC (zone 2)
Nominal switching voltage
≤ 125 V AC / 110 V DC (safe area) ≤ 32 V AC / 32 V DC (zone 2)
Power rating
≤ 62.5 VA / 32 W (safe area) ≤ 16 VA / 32 W (Zone 2)
Type
Status relay, 1 NC (voltage-free)
Accuracy
<0.1% span
Configuration
With FDT/DTM software, Requires configuration adapter 8978580000 CBX200 USB
HART® transparency supported
Yes
Humidity
0...95 % (no condensation)
Power consumption
≤ 1.9 W
Protection degree
IP20
Step response time
≤ 5 ms
Temperature coefficient
<0.01% of span/°C (TU)
Type of connection
PUSH IN
Type of signal forwarding according to HART®
unchanged
Voltage supply
19.2…31.2 V DC
EMC standards
EN 61326-1
Insulation voltage
2.6 kV (input / output)
Rated voltage
300 V
Standards
EN 61010-1
Current I0
Current loop 93 mA / externally 10 mA
Installation location
Device installed in safe area, zone 2
Marking
II (1) G [Ex ia Ga] IIC/IIB/IIA, II (1) D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I
Power P0
Current loop 0.65 W / externally 0.1 W
Voltage U0
Current loop 28 V / externally 10 V
Description of the "safe state"
analogue Output ≤ 3.6 mA or output ≥ 21 mA
Device type
A
Tproof
5 a
Total failure rate for safe detected failures (λSD )
0 FIT
Hardware fault tolerance (HFT)
0
Safety category
SIL 2
Safe Failure Fraction (SFF)
85 %
Mean Time To Repair (MTTR)
24 h
Total failure rate for safe undetected failures (λSU )
164 FIT
Total failure rate for dangerous detected failures (λDD )
127 FIT
Total failure rate for dangerous undetected failures (λDU )
48 FIT
Probability of outage PFH
4.1 x 10-8 h-1
Demand mode
High
Average Probability of Failure on Demand (PFDavg )
1.92 x 10-4 (Tproof = 1 year), 3.67 x 10-4 (Tproof = 2 years), 8.92 x 10-4 (Tproof = 5 years), additional data in the safety manual
Type of connection
PUSH IN
Wire connection cross section AWG, min.
AWG 26
Wire connection cross section AWG, max.
AWG 14
Wire cross-section, solid, min.
0.2 mm²
Wire cross-section, solid, max.
2.5 mm²
Wire connection cross section, finely stranded, min.
0.2 mm²
Wire connection cross section, finely stranded, max.
2.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.
0.2 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.
2.5 mm²
ETIM 6.0
EC002653
ETIM 7.0
EC002653
ETIM 8.0
EC002653
ETIM 9.0
EC002653
ECLASS 9.0
27-21-01-20
ECLASS 9.1
27-21-01-20
ECLASS 10.0
27-21-01-20
ECLASS 11.0
27-21-01-20
ECLASS 12.0
27-21-01-20
ECLASS 13.0
27-21-01-20
Approvals
ROHS
Conform
UL File Number Search
UL Website
Certificate no. (cULus)
E337701
Type of connection:
Screw connection
Order No.:
8965430000
Type:
ACT20X-HAI-SAO-S
Version:
EX signal isolating converter, Ex-input: 4 - 20 mA, Safe-output: 4-20mA, HART® , 1-channel
Type of connection:
Screw connection
Order No.:
8965440000
Type:
ACT20X-2HAI-2SAO-S
Version:
EX signal isolating converter, Ex-input: 4 - 20 mA, Safe-output: 4-20mA, HART® , 2-channel
Type of connection:
PUSH IN
Order No.:
2456150000
Type:
ACT20X-2HAI-2SAO-P
Version:
EX signal isolating converter, Ex-input: 4 - 20 mA, Safe-output: 4-20mA, HART® , 2-channel
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.