Connectivity
Electronics
Automation & Software
Workplace & Accessories
Assembly
Relay Modules & Solid-State Relays
Analogue Signal Conditioning
Power Supplies
Electronics Housings
Lightning and Surge Protection
Photovoltaics
e-mobility
Fieldbus Distributors
Network-compatible current measuring transducers ACT20C
intrinsically safe signal converter - ACT20X
signal converter and process monitoring - ACT20P
Space-saving signal converter - ACT20M
Signal converter in terminal block format - MCZ
Compact standard signal isolators - PicoPak
Process monitoring displays
Analogue-digital / digital-analogue converter
Signal - & serial interface converter– WAVESERIES
Configuration software
Accessories
Signal converters
Passive isolator
Signal splitter
Temperature transducer
Measuring and monitoring relay
Current measuring transducer
Bridge measuring transducer
Frequency converters
Universal
General ordering data
Version
Temperature converter, Limit value monitoring, Input : Temperature, Resistance, Potentiometer, Output : I/U universal, Transistor (Alarm)
Order No.
2448110000
Type
ACT20P-PRO-RTCI-AO-DO-P
GTIN (EAN)
4050118462234
Qty.
1 pc(s).
Dimensions and weights
Depth
113.7 mm
Depth (inches)
4.476 inch
Height
127.1 mm
Height (inches)
5.004 inch
Width
12.5 mm
Width (inches)
0.492 inch
Net weight
0 g
Temperatures
Storage temperature
-40 °C...85 °C
Operating temperature
-40 °C...60 °C
Humidity
5...95 %, no condensation
Environmental Product Compliance
REACH SVHC
Lead 7439-92-1
SCIP
2f6dd957-421a-46db-a0c2-cf1609156924
RoHS Compliance Status
Compliant with exemption
RoHS Exemption (if applicable/known)
7a, 7cI
Input
Input resistance
0…15 kΩ
Input voltage
0...300 mV
Note, technical data 1
see details in instruction sheet
Number of inputs
1
Potentiometer
500 Ω...120 kΩ
Resistance
0…15 kΩ
Sensor
RTD: PT100, PT200, PT500, PT1000, Ni50, Ni100, Ni120, Ni1000, Cu10, Cu25, Cu50, Cu100, RTD (2-wire): KTY83/110, KTY83/120, KTY83/150, KTY83/121, KTY83/122, KTY83/210, KTY83/220, KTY83/221, KTY83/250, KTY82/110, KTY82/120, KTY82/150, KTY82/121, KTY82/122, KTY82/210, KTY82/220, KTY82/221, KTY82/250, KTY84/130, KTY16, KTY19, ST13, ST20, Thermocouples: B, E, J, K, L, N, R, S, T,U, L
Temperature input range
adjustible from -200…+850 °C
Output
Type
active (as current source) or passive (as current sink), connected control can be active / passive
Output (digital)
Alarm function
configurable, Top and bottom limit values, window range, Short circuit at input, Alarm delay: 0…10 s, Hysteresis: 10 V
Number of digital outputs
1
Rated switching current
100 mA
Rated switching voltage
24 VDC ±30%
Switch-on delay
0...180 s, 50 ms ... 7.5 s
Type
NPN-Transitor
Output (analogue)
Load resistance current
≤ 600 Ω
Load resistance voltage
> 1 kΩ (60 VAC <Uin <230 VAC), > 5 kΩ (24 VAC <Uin <60 VAC)
Number of analogue outputs
1
Output current
configurable, 0(4)...20 mA, -20…+20 mA, ± 10mA, upscale (23 mA), downscale (3,5 mA)
Output voltage
configurable, 0(1)...5 V, 0(2)...10 V, -5…+5 V, -10...+10 V, downscale (0 V), upscale (11 V)
Signal output
direct or inverted
Transmit function
linear, √X, X1 , X1.5 , X2 , X2.5 , 1-X, -5…+5 % of output span (TRIM)
Type (analogue output)
Voltage and current output (configurable)
General data
Accuracy
Basic accuracy: ≤ 0.05 % of span, Accuracy of the individual sensor types, see instruction sheet.
Configuration
with push-buttons and display
Galvanic isolation
4-way isolator;, between input ⁄ output ⁄ supply
Included in delivery
Transducer, Instruction sheet
Long-term drift
0.1 % / 10.000 h
Power consumption
≤ 2.6 W
Protection degree
IP20
Rail
TS 35
Step response time
2- / 4- wire: 320 ms;, 3- wire / Poti: 640 ms
Temperature coefficient
±0.01 % of output span / °C
Voltage supply
24…230 V DC ±15%, 110 - 230 V AC / 60-50 Hz
Insulation coordination
EMC standards
EN 61326-1
Galvanic isolation
4-way isolator;, between input ⁄ output ⁄ supply
Impulse withstand voltage
5 kV (1.2/50 µs)
Insulation voltage
4 kVeff / 1 min.
Pollution severity
2
Rated voltage
600 V
Surge voltage category
II
Connection data
Type of connection
PUSH IN
Clamping range, rated connection
2 mm²
Clamping range, min.
0.5 mm²
Clamping range, max.
2 mm²
Wire connection cross section AWG, min.
AWG 26
Wire connection cross section AWG, max.
AWG 14
Wire cross-section, solid, min.
0.2 mm²
Wire cross-section, solid, max.
2.5 mm²
Wire connection cross section, finely stranded, min.
0.2 mm²
Wire connection cross section, finely stranded, max.
2.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.
0.2 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.
2.5 mm²
Important note
Product information
The universal, configurable resistance measuring transducer ACT20P-PRO-RTCI-AO-DOS converts 2- / 3- / 4-wire ohmic resistance and potentiometers into
an active or passive standard current signal or an active voltage signal. For set point Limit Monitoring the device is equipped with an digital NPN Output. The universal power supply can be powerd up from 24Vuc...230Vuc. The device can be configured via the display.
Features
universal wide range supply
universal configurability, LED- Display by touch key
Active or passive signal output
Digital NPN transistor output
Operating status display via frontsided LED
Galvanic 4-way isolation between Input, analogue, digital output and supply
Classifications
ETIM 6.0
EC002919
ETIM 7.0
EC002919
ETIM 8.0
EC002919
ETIM 9.0
EC002919
ECLASS 9.0
27-21-01-29
ECLASS 9.1
27-21-01-29
ECLASS 10.0
27-21-01-29
ECLASS 11.0
27-21-01-29
ECLASS 12.0
27-21-01-29
ECLASS 13.0
27-21-01-29
ECLASS 14.0
27-21-01-29
Order No.:
2448100000
Type of connection:
Screw connection
Type:
ACT20P-PRO-RTCI-AO-DO-S
Version:
Temperature converter, Limit value monitoring, Input : Temperature, Resistance, Potentiometer, Output : I/U universal, Transistor (Alarm)
Order No.:
1453210000
Type of connection:
Screw connection
Type:
ACT20P-UI-AO-DO-LP
Version:
Limit value monitoring, Input : universal U, I, R,ϑ, Output : 4-20 mA, (loop powered), Transistor (Alarm)
Order No.:
2456850000
Type of connection:
PUSH IN
Type:
ACT20P-UI-AO-DO-LP-P
Version:
Signal converter/insulator, Limit value monitoring, Input : universal U, I, R,ϑ, Output : 4-20 mA, (loop powered), Transistor (Alarm)
Order No.:
7760054233
Type of connection:
Screw connection
Type:
ACT20P-RTI-AO-S
Version:
Signal converter/insulator, Input : Temperature, PT100, Output : 0(4)-20 mA
Order No.:
7760054183
Type of connection:
PUSH IN
Type:
ACT20P-RTI-AO-P
Version:
Signal converter/insulator, Input : Temperature, PT100, Output : 0(4)-20 mA
Order No.:
7760054236
Type of connection:
Screw connection
Type:
ACT20P-RTI-2AO-S
Version:
Signal duplicator/isolator, Input : Temperature, PT100, Output : 2 x 0(4) - 20 mA
Order No.:
7760054187
Type of connection:
PUSH IN
Type:
ACT20P-RTI-2AO-P
Version:
Signal duplicator/isolator, Input : Temperature, PT100, Output : 2 x 0(4) - 20 mA
Order No.:
7760054234
Type of connection:
Screw connection
Type:
ACT20P-TCI-AO-S
Version:
Signal converter/insulator, Input : Temperature, thermocouple, Output : 0(4)-20 mA
Order No.:
7760054184
Type of connection:
PUSH IN
Type:
ACT20P-TCI-AO-P
Version:
Signal converter/insulator, Input : Temperature, thermocouple, Output : 0(4)-20 mA
Order No.:
7760054237
Type of connection:
Screw connection
Type:
ACT20P-TCI-2AO-S
Version:
Signal duplicator/isolator, Input : Temperature, thermocouple, Output : 2 x 0(4) - 20 mA
Order No.:
7760054188
Type of connection:
PUSH IN
Type:
ACT20P-TCI-2AO-P
Version:
Signal duplicator/isolator, Input : Temperature, thermocouple, Output : 2 x 0(4) - 20 mA
Order No.:
7760054305
Type of connection:
Screw connection
Type:
ACT20P-TMR-RTI-S
Version:
Limit value monitoring, Input : Temperature, PT100, Output : 2 x relays
Order No.:
7760054352
Type of connection:
PUSH IN
Type:
ACT20P-TMR-RTI-P
Version:
Limit value monitoring, Input : Temperature, PT100, Output : 2 x relays
Order No.:
7940045760
Type of connection:
Screw connection
Type:
ACT20P-UI-2RCO-DC-S
Version:
Limit value monitoring, Input: temperature, R, U, I, Relay output, 24 V DC power supply
Order No.:
2456840000
Type of connection:
PUSH IN
Type:
ACT20P-UI-2RCO-DC-P
Version:
Limit value monitoring, Input: temperature, R, U, I, Relay output, 24 V DC power supply
Order No.:
1238910000
Type of connection:
Screw connection
Type:
ACT20P-UI-2RCO-AC-S
Version:
Limit value monitoring, Input: temperature, R, U, I, Relay output, 90…264 V AC power supply
Order No.:
2495690000
Type of connection:
PUSH IN
Type:
ACT20P-UI-2RCO-AC-P
Version:
Limit value monitoring, Input: temperature, R, U, I, Relay output, 90…264 V AC power supply
Version
Temperature converter, Limit value monitoring, Input : Temperature, Resistance, Potentiometer, Output : I/U universal, Transistor (Alarm)
Order No.
2448110000
Type
ACT20P-PRO-RTCI-AO-DO-P
GTIN (EAN)
4050118462234
Qty.
1 pc(s).
Depth
113.7 mm
Depth (inches)
4.476 inch
Height
127.1 mm
Height (inches)
5.004 inch
Width
12.5 mm
Width (inches)
0.492 inch
Net weight
0 g
Storage temperature
-40 °C...85 °C
Operating temperature
-40 °C...60 °C
Humidity
5...95 %, no condensation
REACH SVHC
Lead 7439-92-1
SCIP
2f6dd957-421a-46db-a0c2-cf1609156924
RoHS Compliance Status
Compliant with exemption
RoHS Exemption (if applicable/known)
7a, 7cI
Input resistance
0…15 kΩ
Input voltage
0...300 mV
Note, technical data 1
see details in instruction sheet
Number of inputs
1
Potentiometer
500 Ω...120 kΩ
Resistance
0…15 kΩ
Sensor
RTD: PT100, PT200, PT500, PT1000, Ni50, Ni100, Ni120, Ni1000, Cu10, Cu25, Cu50, Cu100, RTD (2-wire): KTY83/110, KTY83/120, KTY83/150, KTY83/121, KTY83/122, KTY83/210, KTY83/220, KTY83/221, KTY83/250, KTY82/110, KTY82/120, KTY82/150, KTY82/121, KTY82/122, KTY82/210, KTY82/220, KTY82/221, KTY82/250, KTY84/130, KTY16, KTY19, ST13, ST20, Thermocouples: B, E, J, K, L, N, R, S, T,U, L
Temperature input range
adjustible from -200…+850 °C
Type
active (as current source) or passive (as current sink), connected control can be active / passive
Alarm function
configurable, Top and bottom limit values, window range, Short circuit at input, Alarm delay: 0…10 s, Hysteresis: 10 V
Number of digital outputs
1
Rated switching current
100 mA
Rated switching voltage
24 VDC ±30%
Switch-on delay
0...180 s, 50 ms ... 7.5 s
Type
NPN-Transitor
Load resistance current
≤ 600 Ω
Load resistance voltage
> 1 kΩ (60 VAC <Uin <230 VAC), > 5 kΩ (24 VAC <Uin <60 VAC)
Number of analogue outputs
1
Output current
configurable, 0(4)...20 mA, -20…+20 mA, ± 10mA, upscale (23 mA), downscale (3,5 mA)
Output voltage
configurable, 0(1)...5 V, 0(2)...10 V, -5…+5 V, -10...+10 V, downscale (0 V), upscale (11 V)
Signal output
direct or inverted
Transmit function
linear, √X, X1 , X1.5 , X2 , X2.5 , 1-X, -5…+5 % of output span (TRIM)
Type (analogue output)
Voltage and current output (configurable)
Accuracy
Basic accuracy: ≤ 0.05 % of span, Accuracy of the individual sensor types, see instruction sheet.
Configuration
with push-buttons and display
Galvanic isolation
4-way isolator;, between input ⁄ output ⁄ supply
Included in delivery
Transducer, Instruction sheet
Long-term drift
0.1 % / 10.000 h
Power consumption
≤ 2.6 W
Protection degree
IP20
Rail
TS 35
Step response time
2- / 4- wire: 320 ms;, 3- wire / Poti: 640 ms
Temperature coefficient
±0.01 % of output span / °C
Voltage supply
24…230 V DC ±15%, 110 - 230 V AC / 60-50 Hz
EMC standards
EN 61326-1
Galvanic isolation
4-way isolator;, between input ⁄ output ⁄ supply
Impulse withstand voltage
5 kV (1.2/50 µs)
Insulation voltage
4 kVeff / 1 min.
Pollution severity
2
Rated voltage
600 V
Surge voltage category
II
Type of connection
PUSH IN
Clamping range, rated connection
2 mm²
Clamping range, min.
0.5 mm²
Clamping range, max.
2 mm²
Wire connection cross section AWG, min.
AWG 26
Wire connection cross section AWG, max.
AWG 14
Wire cross-section, solid, min.
0.2 mm²
Wire cross-section, solid, max.
2.5 mm²
Wire connection cross section, finely stranded, min.
0.2 mm²
Wire connection cross section, finely stranded, max.
2.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.
0.2 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.
2.5 mm²
Product information
The universal, configurable resistance measuring transducer ACT20P-PRO-RTCI-AO-DOS converts 2- / 3- / 4-wire ohmic resistance and potentiometers into
an active or passive standard current signal or an active voltage signal. For set point Limit Monitoring the device is equipped with an digital NPN Output. The universal power supply can be powerd up from 24Vuc...230Vuc. The device can be configured via the display.
Features
universal wide range supply
universal configurability, LED- Display by touch key
Active or passive signal output
Digital NPN transistor output
Operating status display via frontsided LED
Galvanic 4-way isolation between Input, analogue, digital output and supply
ETIM 6.0
EC002919
ETIM 7.0
EC002919
ETIM 8.0
EC002919
ETIM 9.0
EC002919
ECLASS 9.0
27-21-01-29
ECLASS 9.1
27-21-01-29
ECLASS 10.0
27-21-01-29
ECLASS 11.0
27-21-01-29
ECLASS 12.0
27-21-01-29
ECLASS 13.0
27-21-01-29
ECLASS 14.0
27-21-01-29
Approvals
ROHS
Conform
UL File Number Search
UL Website
Certificate no. (cULus)
E337701
Order No.:
2448100000
Type of connection:
Screw connection
Type:
ACT20P-PRO-RTCI-AO-DO-S
Version:
Temperature converter, Limit value monitoring, Input : Temperature, Resistance, Potentiometer, Output : I/U universal, Transistor (Alarm)
Order No.:
1453210000
Type of connection:
Screw connection
Type:
ACT20P-UI-AO-DO-LP
Version:
Limit value monitoring, Input : universal U, I, R,ϑ, Output : 4-20 mA, (loop powered), Transistor (Alarm)
Order No.:
2456850000
Type of connection:
PUSH IN
Type:
ACT20P-UI-AO-DO-LP-P
Version:
Signal converter/insulator, Limit value monitoring, Input : universal U, I, R,ϑ, Output : 4-20 mA, (loop powered), Transistor (Alarm)
Order No.:
7760054233
Type of connection:
Screw connection
Type:
ACT20P-RTI-AO-S
Version:
Signal converter/insulator, Input : Temperature, PT100, Output : 0(4)-20 mA
Order No.:
7760054183
Type of connection:
PUSH IN
Type:
ACT20P-RTI-AO-P
Version:
Signal converter/insulator, Input : Temperature, PT100, Output : 0(4)-20 mA
Order No.:
7760054236
Type of connection:
Screw connection
Type:
ACT20P-RTI-2AO-S
Version:
Signal duplicator/isolator, Input : Temperature, PT100, Output : 2 x 0(4) - 20 mA
Order No.:
7760054187
Type of connection:
PUSH IN
Type:
ACT20P-RTI-2AO-P
Version:
Signal duplicator/isolator, Input : Temperature, PT100, Output : 2 x 0(4) - 20 mA
Order No.:
7760054234
Type of connection:
Screw connection
Type:
ACT20P-TCI-AO-S
Version:
Signal converter/insulator, Input : Temperature, thermocouple, Output : 0(4)-20 mA
Order No.:
7760054184
Type of connection:
PUSH IN
Type:
ACT20P-TCI-AO-P
Version:
Signal converter/insulator, Input : Temperature, thermocouple, Output : 0(4)-20 mA
Order No.:
7760054237
Type of connection:
Screw connection
Type:
ACT20P-TCI-2AO-S
Version:
Signal duplicator/isolator, Input : Temperature, thermocouple, Output : 2 x 0(4) - 20 mA
Order No.:
7760054188
Type of connection:
PUSH IN
Type:
ACT20P-TCI-2AO-P
Version:
Signal duplicator/isolator, Input : Temperature, thermocouple, Output : 2 x 0(4) - 20 mA
Order No.:
7760054305
Type of connection:
Screw connection
Type:
ACT20P-TMR-RTI-S
Version:
Limit value monitoring, Input : Temperature, PT100, Output : 2 x relays
Order No.:
7760054352
Type of connection:
PUSH IN
Type:
ACT20P-TMR-RTI-P
Version:
Limit value monitoring, Input : Temperature, PT100, Output : 2 x relays
Order No.:
7940045760
Type of connection:
Screw connection
Type:
ACT20P-UI-2RCO-DC-S
Version:
Limit value monitoring, Input: temperature, R, U, I, Relay output, 24 V DC power supply
Order No.:
2456840000
Type of connection:
PUSH IN
Type:
ACT20P-UI-2RCO-DC-P
Version:
Limit value monitoring, Input: temperature, R, U, I, Relay output, 24 V DC power supply
Order No.:
1238910000
Type of connection:
Screw connection
Type:
ACT20P-UI-2RCO-AC-S
Version:
Limit value monitoring, Input: temperature, R, U, I, Relay output, 90…264 V AC power supply
Order No.:
2495690000
Type of connection:
PUSH IN
Type:
ACT20P-UI-2RCO-AC-P
Version:
Limit value monitoring, Input: temperature, R, U, I, Relay output, 90…264 V AC power supply
This function is provided via the external service provider https://supplyframe.com. By clicking on "Continue" you will be redirected to this page. This leads to a data transfer of personal data to non-European countries. Please check the data protection policy of the external website, for which Weidmüller assumes no responsibility and liability.