ACT20P-PRO-FI-AO-DO-S
         

Icon
Icon
Icon
Icon
 

General ordering data

Version Frequency signal converter, Limit value monitoring, Frequency, PWM, analogue V / mA, Transistor (Alarm)
Order No. 2447940000
Type ACT20P-PRO-FI-AO-DO-S
GTIN (EAN) 4050118462111
Qty. 1 pc(s).

Dimensions and weights

Depth 113.7 mm
Depth (inches) 4.476 inch
Height 117.2 mm
Height (inches) 4.614 inch
Width 12.5 mm
Width (inches) 0.492 inch
Net weight 999 g

Temperatures

Storage temperature -40 °C...85 °C
Operating temperature -40 °C...60 °C
Humidity 0...95 % (no condensation)

Probability of failure

SIL in compliance with IEC 61508 None

Environmental Product Compliance

REACH SVHC Lead 7439-92-1
SCIP 2f6dd957-421a-46db-a0c2-cf1609156924

Input

Input frequency 0,01 Hz…200 kHz
Input voltage Threshold voltage (NPN / PNP Sensor): 3 V...43.5 V (configurable), Hysterisis level: ≥0.5 V
Number of inputs 1
PWM measurement, gate time 20 ms … 20 s
PWM measurement, step response time 20 ms … 20 s + 20 ms
Pulse duty factor 0–-100% push/pull or push, parameterisable
Sensor NPN / PNP transistor (trig-level low: ≤4 V high: ≥7 V ), NAMUR sensor, according to EN60947-5-6, switch with or without RS, RP, 2-wire transmitter (without own power supply), 3 wire NPN/PNP-transistor, frequency generator, PDM
Sensor supply 18 V ±15 %, 8.2 V ±15% (@ NAMUR sensor)
Type frequency or PWM

Output (digital)

Alarm function configurable, Top and bottom limit values, window range, Short circuit at input, Alarm delay: 0…10 s, Hysteresis adjustable
Hysteresis 1...20 %
Number of digital outputs
Rated switching current 100 mA
Rated switching voltage 24 VDC ±30%
Switch-on delay 0...180 s
Type NPN-Transitor, Switching frequency 5 kHz

Output (analogue)

Load resistance current ≤ 600 Ω
Load resistance voltage ≥ 1 kΩ
Number of analogue outputs
Output current -20…+20 mA, ± 10mA, 0(4)...20 mA, configurable downscale (3.5 mA) ⁄ upscale (23 mA) @ error
Output voltage 0...5 V, 0(1)...5 V, 0(2)...10 V, -5…+5 V, -10...+10 V
Signal output direct or inverted
Transmit function linear, √X, X1, X1.5, X2, X2.5, 1-X, direct or inverted, -5…+5 % of output span (TRIM)
Type (analogue output) Voltage and current output (configurable)

General data

Accuracy <±0.1 % of span
Configuration with push-buttons and display
Galvanic isolation 4-way isolator;
Long-term drift ≤±0.05% of the measurement range / year
Power consumption ≤ 2.6 W
Protection degree IP20
Rail TS 35
Step response time 40 ms + period
Temperature coefficient ≤ 0.02 % / °C, ≤ 100 ppm/K of final value
Voltage supply 24…230 V DC ±15%, 24…230 V AC ±15% @48…62 Hz

Insulation coordination

EMC standards EN 61326-1
Galvanic isolation 4-way isolator;
Impulse withstand voltage 5 kV (1.2/50 µs)
Insulation voltage 4 kVeff / 1 min.
Pollution severity 2
Rated voltage 600 V
Surge voltage category II

Safety-related basic specifications

Safety category No

Connection data

Type of connection Screw connection

Downloads

Classifications

ETIM 6.0 EC002918
ETIM 7.0 EC002918
ETIM 8.0 EC002918
ETIM 9.0 EC002918
ECLASS 9.0 27-21-01-28
ECLASS 9.1 27-21-01-28
ECLASS 10.0 27-21-01-28
ECLASS 11.0 27-21-01-28
ECLASS 12.0 27-21-01-28
ECLASS 13.0 27-21-01-28

Approvals

Approvals BURVER CE DETNORVER
ROHS Conform

Related products

Order No.: 2447950000
Type of connection: PUSH IN
Type: ACT20P-PRO-FI-AO-DO-P
Version:
Frequency signal converter, Limit value monitoring, Frequency, PWM, analogue V / mA, Transistor (Alarm)
 
Contact
Weidmüller Interface GmbH & Co. KG
 
+49 5231 14-0
+49 5231 14-292083
More information
Decentralised automation solutions
Energy Management Solutions
Industrial Analytics
Industrial IoT Solutions
More information
Mobility Concepts
Photovoltaics
Wind Solutions
Workplace Solutions
More information
Single Pair Ethernet
Weidmüller Configurator
Support & Service
Contact
Disposal Instructions
Engineering data
Repairs and replacement parts